Reliability of the 6-minute walk test and cardiac autonomic markers in active and sedentary older women

Detalhes bibliográficos
Autor(a) principal: Fonteles, André Igor
Data de Publicação: 2016
Outros Autores: Machado, Daniel Gomes da Silva, Agrícola, Pedro Moraes Dutra, Nascimento Neto, Luiz Inácio, Moreira, Sérgio Rodrigues, Elsangedy, Hassan Mohamed, Chao, Cheng Hsin Nery, Okano, Alexandre Hideki
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
Texto Completo: https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2016v18n3p287
Resumo: The aim of this study was to examine the reliability of the 6-minute walk test (6MWT) and post-exercise cardiac autonomic markers in physically active and sedentary older women. Eighteen physically active older women (64.2±3.1 years; 63.0±2.7 kg; 1.52±0.06 m; 26.9±2.7 kg.m-2) who performed Tai Chi Chuan for at least 6 months, and 18 sedentary older women (64.0±3.7 years; 63.8±8.9 kg; 1.49±0.05 m; 28.4±3.5 kg.m-2) were submitted to 6MWT in two separate occasions. Immediately after 6MWT, heart rate recovery at one (HRR1’) and two minutes (HRR2’), as well as the heart rate variability (HRV) were recoded. Reliability was verified by intraclass correlation coefficient (ICC) with 95% confidence interval, Bland-Altman plots were used as a measure of agreement, and coefficient of variation (CV) was calculated. High reliability (ICC=0.86) was found for performance in 6MWT (528.8 ± 71.4 m and 473.2 ± 62.4 m; CV=7.9 and VC=8.5%) in both groups. Likewise, high reliability (ICC≥0.84 and ICC≥0.80) was found for HRR 1’ (29.0±11.0 bpm and 17.0±8.0 bpm; VC=30.1% and VC =40.2%) and HRR 2’ (36.0±10.0 bpm and 24.0±9.0 bpm; VC =23.7% and VC =22.8%) in both groups. Regarding HRV, moderate reliability was found in the active group (CCI≥0.57; VC =35-47%), while moderate-high reliability was found in the sedentary group (CCI=0.65-0.76; VC=34-69%). Agreement was found for all variables analyzed. In conclusion, post-exercise 6MWT, HRR, and HRV are reliable tools to assess functional capacity and cardiac autonomic control in physically active and sedentary older women.
id UFSC-16_c5e56628eda348342321356a6d4df936
oai_identifier_str oai:periodicos.ufsc.br:article/41440
network_acronym_str UFSC-16
network_name_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository_id_str
spelling Reliability of the 6-minute walk test and cardiac autonomic markers in active and sedentary older womenReprodutibilidade do teste de caminhada de 6 minutos e marcadores autonômicos cardíacos em idosas ativas e sedentáriasThe aim of this study was to examine the reliability of the 6-minute walk test (6MWT) and post-exercise cardiac autonomic markers in physically active and sedentary older women. Eighteen physically active older women (64.2±3.1 years; 63.0±2.7 kg; 1.52±0.06 m; 26.9±2.7 kg.m-2) who performed Tai Chi Chuan for at least 6 months, and 18 sedentary older women (64.0±3.7 years; 63.8±8.9 kg; 1.49±0.05 m; 28.4±3.5 kg.m-2) were submitted to 6MWT in two separate occasions. Immediately after 6MWT, heart rate recovery at one (HRR1’) and two minutes (HRR2’), as well as the heart rate variability (HRV) were recoded. Reliability was verified by intraclass correlation coefficient (ICC) with 95% confidence interval, Bland-Altman plots were used as a measure of agreement, and coefficient of variation (CV) was calculated. High reliability (ICC=0.86) was found for performance in 6MWT (528.8 ± 71.4 m and 473.2 ± 62.4 m; CV=7.9 and VC=8.5%) in both groups. Likewise, high reliability (ICC≥0.84 and ICC≥0.80) was found for HRR 1’ (29.0±11.0 bpm and 17.0±8.0 bpm; VC=30.1% and VC =40.2%) and HRR 2’ (36.0±10.0 bpm and 24.0±9.0 bpm; VC =23.7% and VC =22.8%) in both groups. Regarding HRV, moderate reliability was found in the active group (CCI≥0.57; VC =35-47%), while moderate-high reliability was found in the sedentary group (CCI=0.65-0.76; VC=34-69%). Agreement was found for all variables analyzed. In conclusion, post-exercise 6MWT, HRR, and HRV are reliable tools to assess functional capacity and cardiac autonomic control in physically active and sedentary older women.Objetivou-se verificar a reprodutibilidade do teste de caminhada de 6 minutos (TC6) e de marcadores autonômicos cardíacos pós-esforço em idosas fisicamente ativas e sedentárias. Dezoito idosas ativas (64,2 ± 3,1 anos; 63,0 ± 2,7 kg; 1,52 ± 0,06 m; 26,9 ± 2,7 kg.m-2) praticantes de Tai Chi Chuan (≥6 meses de prática) e 18 idosas sedentárias (64,0 ± 3,7 anos; 63,8 ± 8,9 kg; 1,49 ± 0,05 m; 28,4 ± 3,5 kg.m-2) foram submetidas a dois TC6 com uma semana de intervalo. Foram medidas a frequência cardíaca de recuperação (FCR) de um e dois minutos (FCR1’ e FCR2’, respectivamente) e variabilidade da frequência cardíaca (VFC) pós-esforço. A reprodutibilidade foi verificada pelos: coeficiente de correlação intraclasse (CCI) com 95% de intervalo de confiança; análise de concordância de Bland-Altman; e coeficiente de variação (CV). O desempenho no TC6 (528,8±71,4 m e 473,2±62,4 m; CV=7,9% e CV=8,5%) apresentou alta reprodutibilidade (CCI=0,86) em idosas ativas e sedentárias, respectivamente. Similarmente, as medidas pós-esforço da FCR1’ (29,0±11,0 bpm e 17,0±8,0 bpm; CV=30,1% e CV=40,2%) e FCR2’ (36,0±10,0 bpm e 24,0±9,0 bpm; CV=23,7% e CV=22,8%) apresentaram alta reprodutibilidade (CCI≥0,84 e CCI≥0,80) em ambos os grupos. Quanto a VFC verificou-se reprodutibilidade moderada (CCI≥0,57; CV=35-47%) em idosas ativas e moderada-alta nas sedentárias (CCI=0,65-0,76; CV=34-69%). Todas as variáveis apresentaram concordância em ambos os grupos. Conclui-se que o TC6, FCR e VFC pós-esforço são instrumentos reprodutíveis na avaliação da capacidade funcional e controle autonômico cardíaco em idosas ativas e sedentárias.Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil2016-07-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Avaliado por Pares",Original paperAvaliado por ParesArtigos Originaisapplication/pdfhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2016v18n3p28710.1590/1980-0037.2016v18n3p287Brazilian Journal of Kinanthropometry and Human Performance; Vol. 18 No. 3 (2016); 287-296Revista Brasileira de Cineantropometria e Desempenho Humano; v. 18 n. 3 (2016); 287-2961980-00371415-8426reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)instname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCenghttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2016v18n3p287/32162Copyright (c) 2016 Revista Brasileira de Cineantropometria e Desempenho Humanoinfo:eu-repo/semantics/openAccessFonteles, André IgorMachado, Daniel Gomes da SilvaAgrícola, Pedro Moraes DutraNascimento Neto, Luiz InácioMoreira, Sérgio RodriguesElsangedy, Hassan MohamedChao, Cheng Hsin NeryOkano, Alexandre Hideki2018-12-05T09:47:22Zoai:periodicos.ufsc.br:article/41440Revistahttps://periodicos.ufsc.br/index.php/rbcdh/PUBhttps://periodicos.ufsc.br/index.php/rbcdh/oairbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br1980-00371415-8426opendoar:2018-12-05T09:47:22Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Reliability of the 6-minute walk test and cardiac autonomic markers in active and sedentary older women
Reprodutibilidade do teste de caminhada de 6 minutos e marcadores autonômicos cardíacos em idosas ativas e sedentárias
title Reliability of the 6-minute walk test and cardiac autonomic markers in active and sedentary older women
spellingShingle Reliability of the 6-minute walk test and cardiac autonomic markers in active and sedentary older women
Fonteles, André Igor
title_short Reliability of the 6-minute walk test and cardiac autonomic markers in active and sedentary older women
title_full Reliability of the 6-minute walk test and cardiac autonomic markers in active and sedentary older women
title_fullStr Reliability of the 6-minute walk test and cardiac autonomic markers in active and sedentary older women
title_full_unstemmed Reliability of the 6-minute walk test and cardiac autonomic markers in active and sedentary older women
title_sort Reliability of the 6-minute walk test and cardiac autonomic markers in active and sedentary older women
author Fonteles, André Igor
author_facet Fonteles, André Igor
Machado, Daniel Gomes da Silva
Agrícola, Pedro Moraes Dutra
Nascimento Neto, Luiz Inácio
Moreira, Sérgio Rodrigues
Elsangedy, Hassan Mohamed
Chao, Cheng Hsin Nery
Okano, Alexandre Hideki
author_role author
author2 Machado, Daniel Gomes da Silva
Agrícola, Pedro Moraes Dutra
Nascimento Neto, Luiz Inácio
Moreira, Sérgio Rodrigues
Elsangedy, Hassan Mohamed
Chao, Cheng Hsin Nery
Okano, Alexandre Hideki
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Fonteles, André Igor
Machado, Daniel Gomes da Silva
Agrícola, Pedro Moraes Dutra
Nascimento Neto, Luiz Inácio
Moreira, Sérgio Rodrigues
Elsangedy, Hassan Mohamed
Chao, Cheng Hsin Nery
Okano, Alexandre Hideki
description The aim of this study was to examine the reliability of the 6-minute walk test (6MWT) and post-exercise cardiac autonomic markers in physically active and sedentary older women. Eighteen physically active older women (64.2±3.1 years; 63.0±2.7 kg; 1.52±0.06 m; 26.9±2.7 kg.m-2) who performed Tai Chi Chuan for at least 6 months, and 18 sedentary older women (64.0±3.7 years; 63.8±8.9 kg; 1.49±0.05 m; 28.4±3.5 kg.m-2) were submitted to 6MWT in two separate occasions. Immediately after 6MWT, heart rate recovery at one (HRR1’) and two minutes (HRR2’), as well as the heart rate variability (HRV) were recoded. Reliability was verified by intraclass correlation coefficient (ICC) with 95% confidence interval, Bland-Altman plots were used as a measure of agreement, and coefficient of variation (CV) was calculated. High reliability (ICC=0.86) was found for performance in 6MWT (528.8 ± 71.4 m and 473.2 ± 62.4 m; CV=7.9 and VC=8.5%) in both groups. Likewise, high reliability (ICC≥0.84 and ICC≥0.80) was found for HRR 1’ (29.0±11.0 bpm and 17.0±8.0 bpm; VC=30.1% and VC =40.2%) and HRR 2’ (36.0±10.0 bpm and 24.0±9.0 bpm; VC =23.7% and VC =22.8%) in both groups. Regarding HRV, moderate reliability was found in the active group (CCI≥0.57; VC =35-47%), while moderate-high reliability was found in the sedentary group (CCI=0.65-0.76; VC=34-69%). Agreement was found for all variables analyzed. In conclusion, post-exercise 6MWT, HRR, and HRV are reliable tools to assess functional capacity and cardiac autonomic control in physically active and sedentary older women.
publishDate 2016
dc.date.none.fl_str_mv 2016-07-14
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
"Avaliado por Pares",
Original paper
Avaliado por Pares
Artigos Originais
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2016v18n3p287
10.1590/1980-0037.2016v18n3p287
url https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2016v18n3p287
identifier_str_mv 10.1590/1980-0037.2016v18n3p287
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2016v18n3p287/32162
dc.rights.driver.fl_str_mv Copyright (c) 2016 Revista Brasileira de Cineantropometria e Desempenho Humano
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2016 Revista Brasileira de Cineantropometria e Desempenho Humano
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
dc.source.none.fl_str_mv Brazilian Journal of Kinanthropometry and Human Performance; Vol. 18 No. 3 (2016); 287-296
Revista Brasileira de Cineantropometria e Desempenho Humano; v. 18 n. 3 (2016); 287-296
1980-0037
1415-8426
reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
collection Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository.name.fl_str_mv Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv rbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br
_version_ 1789435124476018688