Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement.

Detalhes bibliográficos
Autor(a) principal: Radaelli, Regis
Data de Publicação: 2011
Outros Autores: Nestor Wilhelm Neto, Eurico, Bottaro, Martim, Silveira Pinto, Ronei
Tipo de documento: Artigo
Idioma: por
Título da fonte: Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
Texto Completo: https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87
Resumo: The aims of this study were: a) to investigate differences in muscle thickness (MT) measured by ultrasound and muscle quality (MQ) at three sites in the elbow flexors and knee extensors, and b) to correlate MT with isometric force production of the elbow flexors and knee extensors. Sixty-nine young male subjects participated in this study. The isometric force production values of the elbow flexors and knee extensors were obtained at 90° and 60°, respectively. MT was assessed at three sites in the elbow flexors (proximal – BB1, middle – BB2, and distal – BB3) and knee extensors (proximal – RI1, middle – RI2, and distal – RI3). Differences between the three measurements of MT and MQ were evaluated by one-way repeated measures ANOVA. Pearson’s correlation test was used to assess the correlation between MT and isometric force. The level of significance was set at p<0.05. The results showed significant differences (p<0.001) between the three MT and MQ sites in the elbow flexors (BB1, BB2, BB3) and in the knee extensors (RI1, RI2, RI3). The correlation between BB1, BB2 and BB3 and force production was r=0.57, r=0.52 and r=0.59, respectively (p<0.05). In the knee extensors, the correlation between RI1, RI2 and RI3 and force production was r=0.47, r=0.51 and r=0.53, respectively (p<0.01).  There were significant differences in MQ between elbow flexors (p<0.001) and knee extensors  (p<0.001). The present results showed that the site of measurement has a significant influence on MT and MQ. Furthermore, MT was positively correlated with isometric force production in the elbow flexors and knee extensors.
id UFSC-16_c6456acee3a64834fa0d64ed09286189
oai_identifier_str oai:periodicos.ufsc.br:article/13934
network_acronym_str UFSC-16
network_name_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository_id_str
spelling Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement.Espessura e qualidade musculares medidas a partir de ultrassonografia: influência de diferentes locais de mensuraçãoThe aims of this study were: a) to investigate differences in muscle thickness (MT) measured by ultrasound and muscle quality (MQ) at three sites in the elbow flexors and knee extensors, and b) to correlate MT with isometric force production of the elbow flexors and knee extensors. Sixty-nine young male subjects participated in this study. The isometric force production values of the elbow flexors and knee extensors were obtained at 90° and 60°, respectively. MT was assessed at three sites in the elbow flexors (proximal – BB1, middle – BB2, and distal – BB3) and knee extensors (proximal – RI1, middle – RI2, and distal – RI3). Differences between the three measurements of MT and MQ were evaluated by one-way repeated measures ANOVA. Pearson’s correlation test was used to assess the correlation between MT and isometric force. The level of significance was set at p<0.05. The results showed significant differences (p<0.001) between the three MT and MQ sites in the elbow flexors (BB1, BB2, BB3) and in the knee extensors (RI1, RI2, RI3). The correlation between BB1, BB2 and BB3 and force production was r=0.57, r=0.52 and r=0.59, respectively (p<0.05). In the knee extensors, the correlation between RI1, RI2 and RI3 and force production was r=0.47, r=0.51 and r=0.53, respectively (p<0.01).  There were significant differences in MQ between elbow flexors (p<0.001) and knee extensors  (p<0.001). The present results showed that the site of measurement has a significant influence on MT and MQ. Furthermore, MT was positively correlated with isometric force production in the elbow flexors and knee extensors.Os objetivos do presente estudo foram: a) observar se há diferença entre os valores de espessura muscular (EM) medidos por ultrassonografia e qualidade muscular (QM) de três diferentes pontos nos músculos flexores de cotovelo e extensores de joelho, b) analisar a correlação das medidas de EM e força isométrica de flexão de cotovelo e extensão de joelho. Sessenta e nove sujeitos homens, fisicamente ativos, participaram do estudo. Os valores de produção de força isométrica de flexão de cotovelo e extensão de joelho foram obtidos nos ângulos de 90° e 60°, respectivamente. A medida de EM foi realizada em três pontos nos flexores de cotovelo (proximal – BB1, médio - BB2, e distal – BB3) e extensores de joelho (proximal – RI1, medial - RI2, e distal – RI3). As diferenças entre as três medidas de EM e QM foram avaliadas por meio da one-way ANOVA para medidas repetidas, e a correlação entre EM e produção de força foi testada utilizando correlação de Pearson. O nível de significância utilizado foi de p<0,05. A EM e a QM diferiram estatisticamente nos três pontos de medidas, tanto nos flexores do cotovelo quanto nos extensores do joelho (p<0,001). As correlações entre as medidas de EM dos flexores de cotovelo nos pontos BB1, BB2 e BB3 e a produção de força isométrica foram r=0,57, r=0,52 e r=0,59 (p<0,05), respectivamente. Já nos extensores de joelho, estas foram de r=0,47, r=0,51 e r=0,53 (p<0,01), nos pontos RI1, RI2, e RI3, respectivamente. Os resultados do presente estudo demonstraram que o ponto de medida exerce influência significativa na EM e QM. Os valores de EM relacionam-se com os de produção de força isométrica dos flexores de cotovelo e extensores de joelhoUniversidade Federal de Santa Catarina. Florianópolis, SC. Brasil2011-02-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Avaliado por Pares",DescriptiveAvaliado por ParesDescritivoapplication/pdfapplication/pdfhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p8710.1590/1980-0037.2011v13n2p87Brazilian Journal of Kinanthropometry and Human Performance; Vol. 13 No. 2 (2011); 87-93Revista Brasileira de Cineantropometria e Desempenho Humano; v. 13 n. 2 (2011); 87-931980-00371415-8426reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)instname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCporhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87/16946https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87/16947Radaelli, RegisNestor Wilhelm Neto, EuricoBottaro, MartimSilveira Pinto, Roneiinfo:eu-repo/semantics/openAccess2022-11-21T14:14:52Zoai:periodicos.ufsc.br:article/13934Revistahttps://periodicos.ufsc.br/index.php/rbcdh/PUBhttps://periodicos.ufsc.br/index.php/rbcdh/oairbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br1980-00371415-8426opendoar:2022-11-21T14:14:52Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement.
Espessura e qualidade musculares medidas a partir de ultrassonografia: influência de diferentes locais de mensuração
title Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement.
spellingShingle Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement.
Radaelli, Regis
title_short Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement.
title_full Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement.
title_fullStr Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement.
title_full_unstemmed Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement.
title_sort Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement.
author Radaelli, Regis
author_facet Radaelli, Regis
Nestor Wilhelm Neto, Eurico
Bottaro, Martim
Silveira Pinto, Ronei
author_role author
author2 Nestor Wilhelm Neto, Eurico
Bottaro, Martim
Silveira Pinto, Ronei
author2_role author
author
author
dc.contributor.author.fl_str_mv Radaelli, Regis
Nestor Wilhelm Neto, Eurico
Bottaro, Martim
Silveira Pinto, Ronei
description The aims of this study were: a) to investigate differences in muscle thickness (MT) measured by ultrasound and muscle quality (MQ) at three sites in the elbow flexors and knee extensors, and b) to correlate MT with isometric force production of the elbow flexors and knee extensors. Sixty-nine young male subjects participated in this study. The isometric force production values of the elbow flexors and knee extensors were obtained at 90° and 60°, respectively. MT was assessed at three sites in the elbow flexors (proximal – BB1, middle – BB2, and distal – BB3) and knee extensors (proximal – RI1, middle – RI2, and distal – RI3). Differences between the three measurements of MT and MQ were evaluated by one-way repeated measures ANOVA. Pearson’s correlation test was used to assess the correlation between MT and isometric force. The level of significance was set at p<0.05. The results showed significant differences (p<0.001) between the three MT and MQ sites in the elbow flexors (BB1, BB2, BB3) and in the knee extensors (RI1, RI2, RI3). The correlation between BB1, BB2 and BB3 and force production was r=0.57, r=0.52 and r=0.59, respectively (p<0.05). In the knee extensors, the correlation between RI1, RI2 and RI3 and force production was r=0.47, r=0.51 and r=0.53, respectively (p<0.01).  There were significant differences in MQ between elbow flexors (p<0.001) and knee extensors  (p<0.001). The present results showed that the site of measurement has a significant influence on MT and MQ. Furthermore, MT was positively correlated with isometric force production in the elbow flexors and knee extensors.
publishDate 2011
dc.date.none.fl_str_mv 2011-02-15
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
"Avaliado por Pares",
Descriptive
Avaliado por Pares
Descritivo
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87
10.1590/1980-0037.2011v13n2p87
url https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87
identifier_str_mv 10.1590/1980-0037.2011v13n2p87
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87/16946
https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87/16947
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
dc.source.none.fl_str_mv Brazilian Journal of Kinanthropometry and Human Performance; Vol. 13 No. 2 (2011); 87-93
Revista Brasileira de Cineantropometria e Desempenho Humano; v. 13 n. 2 (2011); 87-93
1980-0037
1415-8426
reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
collection Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository.name.fl_str_mv Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv rbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br
_version_ 1789435122216337408