Reproducibility of auscultatory blood pressure measurement during resistance exercise.

Detalhes bibliográficos
Autor(a) principal: Andrade, Danyele Moura de
Data de Publicação: 2012
Outros Autores: Meneses, Annelise Lins, Almeida, Tarciso Rogério Medeiros de, Miranda, Alessandra de Souza, Ritti-Dias, Raphael Mendes
Tipo de documento: Artigo
Idioma: por
Título da fonte: Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
Texto Completo: https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n4p450
Resumo: The auscultatory method has been suggested as a viable option for blood pressure (BP) measurement during resistance exercise. However, indicators of reproducibility of this method during resistance exercise have not been established. This study aimed to analyze intra- and inter-examiner reproducibility of auscultatory BP measurements obtained du­ring resistance exercise. Fourteen subjects (24 ± 5 years; 22.0 ± 2.4 kg/m2; systolic BP, 116 ± 7 mmHg; diastolic BP, 75 ± 4 mmHg) performed three sets of 15 repetitions of the knee extension exercise at 50% of their 1-repetition maximum at two different time points (T1 and T2). Before and during exercise, systolic and diastolic BP were measured simultaneously in both arms by two examiners. The intra-examiner intraclass correlation coefficient (ICC) for systolic BP was 0.75 (0.57-0.86) and 0.76 (0.59-0.87) for examiners 1 and 2, respectively. In addition, systolic BP values were similar at T1 and T2 both for examiner 1 (144 ± 9 vs. 146 ± 18, p = 0.08) and examiner 2 (152 ± 9 vs. 153 ± 12, p = 0.32). Inter-examiner ICC was 0.68 (0.46-0.82) for systolic BP and 0.21 (0.11-0.50) for diastolic BP. It can be conclu­ded that auscultatory systolic BP measurement during resistance exercise shows intra- and inter-examiner reproducibility ranging from 0.68 to 0.76, whereas diastolic BP measurement during resistance exercise shows low reproducibility.
id UFSC-16_dba3f9839f2324757b629381b0dc9ea9
oai_identifier_str oai:periodicos.ufsc.br:article/21939
network_acronym_str UFSC-16
network_name_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository_id_str
spelling Reproducibility of auscultatory blood pressure measurement during resistance exercise.Reprodutibilidade da medida da pressão arterial auscultatória durante o exercício de Força.The auscultatory method has been suggested as a viable option for blood pressure (BP) measurement during resistance exercise. However, indicators of reproducibility of this method during resistance exercise have not been established. This study aimed to analyze intra- and inter-examiner reproducibility of auscultatory BP measurements obtained du­ring resistance exercise. Fourteen subjects (24 ± 5 years; 22.0 ± 2.4 kg/m2; systolic BP, 116 ± 7 mmHg; diastolic BP, 75 ± 4 mmHg) performed three sets of 15 repetitions of the knee extension exercise at 50% of their 1-repetition maximum at two different time points (T1 and T2). Before and during exercise, systolic and diastolic BP were measured simultaneously in both arms by two examiners. The intra-examiner intraclass correlation coefficient (ICC) for systolic BP was 0.75 (0.57-0.86) and 0.76 (0.59-0.87) for examiners 1 and 2, respectively. In addition, systolic BP values were similar at T1 and T2 both for examiner 1 (144 ± 9 vs. 146 ± 18, p = 0.08) and examiner 2 (152 ± 9 vs. 153 ± 12, p = 0.32). Inter-examiner ICC was 0.68 (0.46-0.82) for systolic BP and 0.21 (0.11-0.50) for diastolic BP. It can be conclu­ded that auscultatory systolic BP measurement during resistance exercise shows intra- and inter-examiner reproducibility ranging from 0.68 to 0.76, whereas diastolic BP measurement during resistance exercise shows low reproducibility.O método auscultatório tem sido sugerido como opção viável para a medida da pressão arterial (PA) durante o exercício de força. Todavia, os indicadores de reprodutibilidade deste método durante o exercício de força ainda não foram estabelecidos. O objetivo do estudo foi analisar a reprodutibilidade intra e interavaliadores da medida da PA auscultatória obtida durante o exercício de força. Quatorze sujeitos (24±5 anos; 22,0±2,4 kg/m2; PA sistólica: 116±7 mmHg e PA diastólica: 75±4 mmHg) realizaram três séries de 15 repetições, com 50% de 1-repetição máxima no exercício extensão de joelhos em dois momentos distintos (M1 e M2). Antes e durante os séries, a PA sistólica e diastólica foram medidas em ambos os braços simultaneamente por dois avaliadores. O coeficiente de correlação intraclasse (ICC) intra-avaliador da PA sistólica foi de 0,75 (0,57–0,86) e 0,76 (0,59–0,87) para os avaliadores 1 e 2, respectivamente. Além disso, os valores da PA sistólica foram similares entre o M1 e M2, tanto para o avaliador 1 (144±9 vs 146±18, p=0,08), como para o avaliador 2 (152±9 vs. 153±12, p=0,32). O ICC interavaliadores da PA sistólica foi 0,68 (0,46 – 0,82) e o da PA diastólica foi de 0,21 (0,11–0,50). Pode-se concluir que a medida auscultatória da PA sistólica durante o exercício de força apresenta reprodutibilidade intra e interavaliadores, variando de 0,68 a 0,76, ao passo que a medida PA diastólica, durante o exercício de força, apresenta baixos níveis de reprodutibilidade.Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil2012-06-20info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Avaliado por Pares",DescriptiveAvaliado por ParesDescritivoapplication/pdfhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n4p45010.1590/1980-0037.2012v14n4p450Brazilian Journal of Kinanthropometry and Human Performance; Vol. 14 No. 4 (2012); 450-459Revista Brasileira de Cineantropometria e Desempenho Humano; v. 14 n. 4 (2012); 450-4591980-00371415-8426reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)instname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCporhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n4p450/22176Andrade, Danyele Moura deMeneses, Annelise LinsAlmeida, Tarciso Rogério Medeiros deMiranda, Alessandra de SouzaRitti-Dias, Raphael Mendesinfo:eu-repo/semantics/openAccess2022-11-21T14:14:56Zoai:periodicos.ufsc.br:article/21939Revistahttps://periodicos.ufsc.br/index.php/rbcdh/PUBhttps://periodicos.ufsc.br/index.php/rbcdh/oairbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br1980-00371415-8426opendoar:2022-11-21T14:14:56Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Reproducibility of auscultatory blood pressure measurement during resistance exercise.
Reprodutibilidade da medida da pressão arterial auscultatória durante o exercício de Força.
title Reproducibility of auscultatory blood pressure measurement during resistance exercise.
spellingShingle Reproducibility of auscultatory blood pressure measurement during resistance exercise.
Andrade, Danyele Moura de
title_short Reproducibility of auscultatory blood pressure measurement during resistance exercise.
title_full Reproducibility of auscultatory blood pressure measurement during resistance exercise.
title_fullStr Reproducibility of auscultatory blood pressure measurement during resistance exercise.
title_full_unstemmed Reproducibility of auscultatory blood pressure measurement during resistance exercise.
title_sort Reproducibility of auscultatory blood pressure measurement during resistance exercise.
author Andrade, Danyele Moura de
author_facet Andrade, Danyele Moura de
Meneses, Annelise Lins
Almeida, Tarciso Rogério Medeiros de
Miranda, Alessandra de Souza
Ritti-Dias, Raphael Mendes
author_role author
author2 Meneses, Annelise Lins
Almeida, Tarciso Rogério Medeiros de
Miranda, Alessandra de Souza
Ritti-Dias, Raphael Mendes
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Andrade, Danyele Moura de
Meneses, Annelise Lins
Almeida, Tarciso Rogério Medeiros de
Miranda, Alessandra de Souza
Ritti-Dias, Raphael Mendes
description The auscultatory method has been suggested as a viable option for blood pressure (BP) measurement during resistance exercise. However, indicators of reproducibility of this method during resistance exercise have not been established. This study aimed to analyze intra- and inter-examiner reproducibility of auscultatory BP measurements obtained du­ring resistance exercise. Fourteen subjects (24 ± 5 years; 22.0 ± 2.4 kg/m2; systolic BP, 116 ± 7 mmHg; diastolic BP, 75 ± 4 mmHg) performed three sets of 15 repetitions of the knee extension exercise at 50% of their 1-repetition maximum at two different time points (T1 and T2). Before and during exercise, systolic and diastolic BP were measured simultaneously in both arms by two examiners. The intra-examiner intraclass correlation coefficient (ICC) for systolic BP was 0.75 (0.57-0.86) and 0.76 (0.59-0.87) for examiners 1 and 2, respectively. In addition, systolic BP values were similar at T1 and T2 both for examiner 1 (144 ± 9 vs. 146 ± 18, p = 0.08) and examiner 2 (152 ± 9 vs. 153 ± 12, p = 0.32). Inter-examiner ICC was 0.68 (0.46-0.82) for systolic BP and 0.21 (0.11-0.50) for diastolic BP. It can be conclu­ded that auscultatory systolic BP measurement during resistance exercise shows intra- and inter-examiner reproducibility ranging from 0.68 to 0.76, whereas diastolic BP measurement during resistance exercise shows low reproducibility.
publishDate 2012
dc.date.none.fl_str_mv 2012-06-20
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
"Avaliado por Pares",
Descriptive
Avaliado por Pares
Descritivo
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n4p450
10.1590/1980-0037.2012v14n4p450
url https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n4p450
identifier_str_mv 10.1590/1980-0037.2012v14n4p450
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n4p450/22176
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
dc.source.none.fl_str_mv Brazilian Journal of Kinanthropometry and Human Performance; Vol. 14 No. 4 (2012); 450-459
Revista Brasileira de Cineantropometria e Desempenho Humano; v. 14 n. 4 (2012); 450-459
1980-0037
1415-8426
reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
collection Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository.name.fl_str_mv Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv rbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br
_version_ 1789435122834997248