Determination of heart rate threshold from heart rate kinetics during maximal graded exercise in soccer players

Detalhes bibliográficos
Autor(a) principal: Marques Neto, Silvio Rodrigues
Data de Publicação: 2019
Outros Autores: Gurgel, Alexandre, Lattari, Eduardo, Faleiro, Viviane, Machado, Sérgio, Farinatti, Paulo, Maranhão Neto, Geraldo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
Texto Completo: https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2019v21e57829
Resumo: The main of the present study was to identify the heart rate threshold based on heart rate kinetics during graded maximal exercise in football players. Twenty-six male football players performed a maximal exercise test (Bruce protocol) on a motor-driven treadmill. Oxygen uptake (VO2) and heart rate (HR) were monitored, recorded and resampled at 3.5Hz. The ventilatory threshold (VT), and respiratory compensation (RC), heart rate deflection points (HRDP1 and HRDP2) and heart rate kinetics threshold (HRT) were determined by computerized methods. The heart rate variability (HRV) was assessed in the frequency domain. The HRT averaged 89.9 ± 1.2 % of the VO2 peak. The HRT showed poor correlations and significant differences compared with HRDP1 (r = 0.46) and VT (r = 0.51), but was not different from, and highly correlated with, HRDP2 (0.98) and RC (0.90). Bland Altman plots showed all athletes into 95% of limits of agreement, and intraclass correlation coefficient showed good agreements between points obtained from HRT compared with HRDP2 (0.96) and RC (0.98). The HRT was highly correlated with HRDP2 and RC, suggesting it could be a marker for cardiorespiratory fatigue.
id UFSC-16_eda8de4d6a1a949da7d3af50ff7831fd
oai_identifier_str oai:periodicos.ufsc.br:article/57829
network_acronym_str UFSC-16
network_name_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository_id_str
spelling Determination of heart rate threshold from heart rate kinetics during maximal graded exercise in soccer playersDeterminação do limiar da frequência cardíaca a partir da cinética da frequência cardíaca durante o exercício graduado máximo em jogadores de futebolThe main of the present study was to identify the heart rate threshold based on heart rate kinetics during graded maximal exercise in football players. Twenty-six male football players performed a maximal exercise test (Bruce protocol) on a motor-driven treadmill. Oxygen uptake (VO2) and heart rate (HR) were monitored, recorded and resampled at 3.5Hz. The ventilatory threshold (VT), and respiratory compensation (RC), heart rate deflection points (HRDP1 and HRDP2) and heart rate kinetics threshold (HRT) were determined by computerized methods. The heart rate variability (HRV) was assessed in the frequency domain. The HRT averaged 89.9 ± 1.2 % of the VO2 peak. The HRT showed poor correlations and significant differences compared with HRDP1 (r = 0.46) and VT (r = 0.51), but was not different from, and highly correlated with, HRDP2 (0.98) and RC (0.90). Bland Altman plots showed all athletes into 95% of limits of agreement, and intraclass correlation coefficient showed good agreements between points obtained from HRT compared with HRDP2 (0.96) and RC (0.98). The HRT was highly correlated with HRDP2 and RC, suggesting it could be a marker for cardiorespiratory fatigue.O objetivo do presente estudo foi identificar o limiar de frequência cardíaca baseado na cinética da frequência cardíaca durante o exercício máximo graduado em jogadores de futebol. Vinte e seis jogadores de futebol masculino realizaram um teste de exercício máximo (protocolo de Bruce) em uma esteira motorizada. O consumo de oxigênio (VO2) e a freqüência cardíaca (FC) foram monitorados, registrados e reamostrados a 3,5Hz. O limiar ventilatório (LV), a compensação respiratória (CR), os pontos de deflexões da frequência cardíaca (PDFC1 e PDFC2) e o limiar da cinética da frequência cardíaca (LCFC) foram determinados por métodos computadorizados. A variabilidade da frequência cardíaca (VFC) foi avaliada no domínio da frequência. A média do LCFC foi de 89,9 ± 1,2% do VO2 de pico. O LCFC demonstrou correlações e diferenças significativas em relação ao PDFC1 (r = 0,46) e ao LV (r = 0,51), mas não foi diferente e altamente correlacionado com PDFC2 (0,98) e CR (0,90). Os gráficos de Bland Altman mostraram todos os atletas em 95% dos limites de concordância, e o coeficiente de correlação intraclasse apresentou boas concordâncias entre os pontos obtidos com o LCFC em comparação com o PDFC2 (0,96) e CR (0,98). A LCFC foi altamente correlacionada com PDFC2 e CR, sugerindo que poderia ser um marcador de fadiga cardiorrespiratória.Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil2019-12-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Avaliado por Pares",Original articleAvaliado por ParesArtigo originalapplication/pdfhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2019v21e5782910.1590/1980-0037.2019v21e57829Brazilian Journal of Kinanthropometry and Human Performance; Vol. 21 (2019); e57829Revista Brasileira de Cineantropometria e Desempenho Humano; v. 21 (2019); e578291980-00371415-8426reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)instname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCenghttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2019v21e57829/42455Copyright (c) 2020 Revista Brasileira de Cineantropometria e Desempenho Humanoinfo:eu-repo/semantics/openAccessMarques Neto, Silvio RodriguesGurgel, AlexandreLattari, EduardoFaleiro, VivianeMachado, SérgioFarinatti, PauloMaranhão Neto, Geraldo2020-02-11T08:50:58Zoai:periodicos.ufsc.br:article/57829Revistahttps://periodicos.ufsc.br/index.php/rbcdh/PUBhttps://periodicos.ufsc.br/index.php/rbcdh/oairbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br1980-00371415-8426opendoar:2020-02-11T08:50:58Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Determination of heart rate threshold from heart rate kinetics during maximal graded exercise in soccer players
Determinação do limiar da frequência cardíaca a partir da cinética da frequência cardíaca durante o exercício graduado máximo em jogadores de futebol
title Determination of heart rate threshold from heart rate kinetics during maximal graded exercise in soccer players
spellingShingle Determination of heart rate threshold from heart rate kinetics during maximal graded exercise in soccer players
Marques Neto, Silvio Rodrigues
title_short Determination of heart rate threshold from heart rate kinetics during maximal graded exercise in soccer players
title_full Determination of heart rate threshold from heart rate kinetics during maximal graded exercise in soccer players
title_fullStr Determination of heart rate threshold from heart rate kinetics during maximal graded exercise in soccer players
title_full_unstemmed Determination of heart rate threshold from heart rate kinetics during maximal graded exercise in soccer players
title_sort Determination of heart rate threshold from heart rate kinetics during maximal graded exercise in soccer players
author Marques Neto, Silvio Rodrigues
author_facet Marques Neto, Silvio Rodrigues
Gurgel, Alexandre
Lattari, Eduardo
Faleiro, Viviane
Machado, Sérgio
Farinatti, Paulo
Maranhão Neto, Geraldo
author_role author
author2 Gurgel, Alexandre
Lattari, Eduardo
Faleiro, Viviane
Machado, Sérgio
Farinatti, Paulo
Maranhão Neto, Geraldo
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Marques Neto, Silvio Rodrigues
Gurgel, Alexandre
Lattari, Eduardo
Faleiro, Viviane
Machado, Sérgio
Farinatti, Paulo
Maranhão Neto, Geraldo
description The main of the present study was to identify the heart rate threshold based on heart rate kinetics during graded maximal exercise in football players. Twenty-six male football players performed a maximal exercise test (Bruce protocol) on a motor-driven treadmill. Oxygen uptake (VO2) and heart rate (HR) were monitored, recorded and resampled at 3.5Hz. The ventilatory threshold (VT), and respiratory compensation (RC), heart rate deflection points (HRDP1 and HRDP2) and heart rate kinetics threshold (HRT) were determined by computerized methods. The heart rate variability (HRV) was assessed in the frequency domain. The HRT averaged 89.9 ± 1.2 % of the VO2 peak. The HRT showed poor correlations and significant differences compared with HRDP1 (r = 0.46) and VT (r = 0.51), but was not different from, and highly correlated with, HRDP2 (0.98) and RC (0.90). Bland Altman plots showed all athletes into 95% of limits of agreement, and intraclass correlation coefficient showed good agreements between points obtained from HRT compared with HRDP2 (0.96) and RC (0.98). The HRT was highly correlated with HRDP2 and RC, suggesting it could be a marker for cardiorespiratory fatigue.
publishDate 2019
dc.date.none.fl_str_mv 2019-12-31
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
"Avaliado por Pares",
Original article
Avaliado por Pares
Artigo original
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2019v21e57829
10.1590/1980-0037.2019v21e57829
url https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2019v21e57829
identifier_str_mv 10.1590/1980-0037.2019v21e57829
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2019v21e57829/42455
dc.rights.driver.fl_str_mv Copyright (c) 2020 Revista Brasileira de Cineantropometria e Desempenho Humano
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2020 Revista Brasileira de Cineantropometria e Desempenho Humano
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
dc.source.none.fl_str_mv Brazilian Journal of Kinanthropometry and Human Performance; Vol. 21 (2019); e57829
Revista Brasileira de Cineantropometria e Desempenho Humano; v. 21 (2019); e57829
1980-0037
1415-8426
reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
collection Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository.name.fl_str_mv Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv rbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br
_version_ 1789435125585412096