Reliability of isometric and isokinetic peak torque of elbow flexors and elbow extensors muscles in trained swimmers

Detalhes bibliográficos
Autor(a) principal: Bassan, Natália Menezes
Data de Publicação: 2015
Outros Autores: Simões, Luiza Bertelli, Cesar, Thadeu Elias Augusto Siqueira, Caritá, Renato Aparecido Corrêa, Lima, Leonardo Coelho Rabelo de, Denadai, Benedito Sérgio, Greco, Camila Coelho
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
Texto Completo: https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2015v17n5p507
Resumo: In this study, it was hypothesized that the peak torque reliability would depend on the type of muscular action. The aim of this study was to analyze and to compare the reliability of isometric peak torque (IPT) and isokinetic peak torque at speeds of 60º.s-1 and 180°.s-1 (CPT60 and CPT180, respectively) of elbow flexors (EF) and elbow extensors (EE) muscles in trained swimmers. Twenty trained male swimmers (23 ± 5 years) performed the following protocols in different days: 1) Familiarization to isokinetic dynamometer; 2) Two maximal isometric voluntary contractions to determine IPT and five maximal concentric isokinetic contractions at 60º.s-1 and 180°.s-1 to determine CPT60 and CPT180, respectively (T1). The tests for IPT, CPT60 and CPT180 determination were performed in random order, and; 3) The same tests were performed in the same order of those performed on the second day (T2). There was no significant difference of IPT, CPT60 and CPT180 values between T1 and T2. Higher intraclass correlation coefficient (ICC) andlower typical error (TE) of IPT (ICC - 0.87 – 0.92; TE - 6.9 – 10.9%) in relation to CPT60 (CCI - 0.66 – 0.79, TE - 12.0 – 12.8%) and CPT180 (ICC - 0.85 - 0.85; TE - 8.5 – 9.2%) was observed. Based on these results, it could be concluded that the peak torque of EF and EE muscles presents moderate to excellent reliability, and can be influenced by the type of muscular action performed by trained swimmers. 
id UFSC-16_fdb7156d7ca11edf7b65c5440d59474a
oai_identifier_str oai:periodicos.ufsc.br:article/37834
network_acronym_str UFSC-16
network_name_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository_id_str
spelling Reliability of isometric and isokinetic peak torque of elbow flexors and elbow extensors muscles in trained swimmersReprodutibilidade do pico de torque isométrico e isocinético dos músculos flexores e extensores de cotovelo em nadadores treinadosIn this study, it was hypothesized that the peak torque reliability would depend on the type of muscular action. The aim of this study was to analyze and to compare the reliability of isometric peak torque (IPT) and isokinetic peak torque at speeds of 60º.s-1 and 180°.s-1 (CPT60 and CPT180, respectively) of elbow flexors (EF) and elbow extensors (EE) muscles in trained swimmers. Twenty trained male swimmers (23 ± 5 years) performed the following protocols in different days: 1) Familiarization to isokinetic dynamometer; 2) Two maximal isometric voluntary contractions to determine IPT and five maximal concentric isokinetic contractions at 60º.s-1 and 180°.s-1 to determine CPT60 and CPT180, respectively (T1). The tests for IPT, CPT60 and CPT180 determination were performed in random order, and; 3) The same tests were performed in the same order of those performed on the second day (T2). There was no significant difference of IPT, CPT60 and CPT180 values between T1 and T2. Higher intraclass correlation coefficient (ICC) andlower typical error (TE) of IPT (ICC - 0.87 – 0.92; TE - 6.9 – 10.9%) in relation to CPT60 (CCI - 0.66 – 0.79, TE - 12.0 – 12.8%) and CPT180 (ICC - 0.85 - 0.85; TE - 8.5 – 9.2%) was observed. Based on these results, it could be concluded that the peak torque of EF and EE muscles presents moderate to excellent reliability, and can be influenced by the type of muscular action performed by trained swimmers. Neste estudo, hipotetizou-se que a reprodutibilidade do pico de torque poderia depender do tipo de ação muscular. O objetivo do presente estudo foi analisar e comparar a reprodutibilidade do pico de torque isométrico (PTI) e do pico de torque isocinético concêntrico nas velocidades de 60º.s-1 e 180°.s-1 (CPT60 e CPT180, respectivamente) dos músculos flexores (FC) e extensores do cotovelo (EC) em nadadores treinados. Vinte nadadores treinados do gênero masculino (23 ± 5 anos) realizaram os seguintes protocolos, em diferentes dias: 1) Familiarização ao dinamômetro isocinético; 2) Duas contrações isométricas máximas para a determinação do PTI e cinco contrações isocinéticas máximas concêntricas a 60º.s-1 e 180°.s-1 para a determinação do CPT60 e CPT180, respectivamente (T1). Os testes para a determinação do PTI, CPT60 e CPT180 foram realizados de forma aleatória e; 3) Foram realizados os mesmos testes e na mesma ordem dos realizados no segundo dia (T2). Não houve diferença significante dos valores de PTI, CPT60 e CPT180 entre T1 e T2. Foi observado maior coeficiente de correlação intraclasse (CCI) e menor erro típico (ET) do PTI (CCI - 0,87 – 0,92; ET - 6,9 – 10,9%) em relação ao CPT60 (CCI - 0,66 – 0,79, ET - 12,0 – 12,8%) e CPT180 (CCI - 0,85- 0,85; ET - 8,5 – 9,2%). Com base nestes resultados, é possível concluir que o pico de torque dos músculos FC e EC apresenta reprodutibilidade entre moderada e excelente, podendo ser influenciada pelo tipo de ação muscular realizada em indivíduos treinados na natação.Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil2015-09-21info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Avaliado por Pares",Original paperAvaliado por ParesArtigos Originaisapplication/pdfhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2015v17n5p50710.1590/1980-0037.2015v17n5p507Brazilian Journal of Kinanthropometry and Human Performance; Vol. 17 No. 5 (2015); 507-516Revista Brasileira de Cineantropometria e Desempenho Humano; v. 17 n. 5 (2015); 507-5161980-00371415-8426reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)instname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCenghttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2015v17n5p507/30103Copyright (c) 2015 Revista Brasileira de Cineantropometria e Desempenho Humanoinfo:eu-repo/semantics/openAccessBassan, Natália MenezesSimões, Luiza BertelliCesar, Thadeu Elias Augusto SiqueiraCaritá, Renato Aparecido CorrêaLima, Leonardo Coelho Rabelo deDenadai, Benedito SérgioGreco, Camila Coelho2018-12-05T09:10:16Zoai:periodicos.ufsc.br:article/37834Revistahttps://periodicos.ufsc.br/index.php/rbcdh/PUBhttps://periodicos.ufsc.br/index.php/rbcdh/oairbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br1980-00371415-8426opendoar:2018-12-05T09:10:16Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Reliability of isometric and isokinetic peak torque of elbow flexors and elbow extensors muscles in trained swimmers
Reprodutibilidade do pico de torque isométrico e isocinético dos músculos flexores e extensores de cotovelo em nadadores treinados
title Reliability of isometric and isokinetic peak torque of elbow flexors and elbow extensors muscles in trained swimmers
spellingShingle Reliability of isometric and isokinetic peak torque of elbow flexors and elbow extensors muscles in trained swimmers
Bassan, Natália Menezes
title_short Reliability of isometric and isokinetic peak torque of elbow flexors and elbow extensors muscles in trained swimmers
title_full Reliability of isometric and isokinetic peak torque of elbow flexors and elbow extensors muscles in trained swimmers
title_fullStr Reliability of isometric and isokinetic peak torque of elbow flexors and elbow extensors muscles in trained swimmers
title_full_unstemmed Reliability of isometric and isokinetic peak torque of elbow flexors and elbow extensors muscles in trained swimmers
title_sort Reliability of isometric and isokinetic peak torque of elbow flexors and elbow extensors muscles in trained swimmers
author Bassan, Natália Menezes
author_facet Bassan, Natália Menezes
Simões, Luiza Bertelli
Cesar, Thadeu Elias Augusto Siqueira
Caritá, Renato Aparecido Corrêa
Lima, Leonardo Coelho Rabelo de
Denadai, Benedito Sérgio
Greco, Camila Coelho
author_role author
author2 Simões, Luiza Bertelli
Cesar, Thadeu Elias Augusto Siqueira
Caritá, Renato Aparecido Corrêa
Lima, Leonardo Coelho Rabelo de
Denadai, Benedito Sérgio
Greco, Camila Coelho
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Bassan, Natália Menezes
Simões, Luiza Bertelli
Cesar, Thadeu Elias Augusto Siqueira
Caritá, Renato Aparecido Corrêa
Lima, Leonardo Coelho Rabelo de
Denadai, Benedito Sérgio
Greco, Camila Coelho
description In this study, it was hypothesized that the peak torque reliability would depend on the type of muscular action. The aim of this study was to analyze and to compare the reliability of isometric peak torque (IPT) and isokinetic peak torque at speeds of 60º.s-1 and 180°.s-1 (CPT60 and CPT180, respectively) of elbow flexors (EF) and elbow extensors (EE) muscles in trained swimmers. Twenty trained male swimmers (23 ± 5 years) performed the following protocols in different days: 1) Familiarization to isokinetic dynamometer; 2) Two maximal isometric voluntary contractions to determine IPT and five maximal concentric isokinetic contractions at 60º.s-1 and 180°.s-1 to determine CPT60 and CPT180, respectively (T1). The tests for IPT, CPT60 and CPT180 determination were performed in random order, and; 3) The same tests were performed in the same order of those performed on the second day (T2). There was no significant difference of IPT, CPT60 and CPT180 values between T1 and T2. Higher intraclass correlation coefficient (ICC) andlower typical error (TE) of IPT (ICC - 0.87 – 0.92; TE - 6.9 – 10.9%) in relation to CPT60 (CCI - 0.66 – 0.79, TE - 12.0 – 12.8%) and CPT180 (ICC - 0.85 - 0.85; TE - 8.5 – 9.2%) was observed. Based on these results, it could be concluded that the peak torque of EF and EE muscles presents moderate to excellent reliability, and can be influenced by the type of muscular action performed by trained swimmers. 
publishDate 2015
dc.date.none.fl_str_mv 2015-09-21
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
"Avaliado por Pares",
Original paper
Avaliado por Pares
Artigos Originais
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2015v17n5p507
10.1590/1980-0037.2015v17n5p507
url https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2015v17n5p507
identifier_str_mv 10.1590/1980-0037.2015v17n5p507
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2015v17n5p507/30103
dc.rights.driver.fl_str_mv Copyright (c) 2015 Revista Brasileira de Cineantropometria e Desempenho Humano
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2015 Revista Brasileira de Cineantropometria e Desempenho Humano
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
dc.source.none.fl_str_mv Brazilian Journal of Kinanthropometry and Human Performance; Vol. 17 No. 5 (2015); 507-516
Revista Brasileira de Cineantropometria e Desempenho Humano; v. 17 n. 5 (2015); 507-516
1980-0037
1415-8426
reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
collection Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository.name.fl_str_mv Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv rbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br
_version_ 1789435124092239872