Avaliação do desempenho de aparelhos de amplificação sonora individual com base em normas internacionais

Detalhes bibliográficos
Autor(a) principal: Masson, Zargos Neves
Data de Publicação: 2016
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/xmlui/handle/123456789/174436
Resumo: Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2016.
id UFSC_025228484c2e729027fde6e0e0b7ea04
oai_identifier_str oai:repositorio.ufsc.br:123456789/174436
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Avaliação do desempenho de aparelhos de amplificação sonora individual com base em normas internacionaisEngenharia mecânicaDistúrbios da audiçãoAparelhos auditivosNormasAvaliaçãoDissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2016.Os aparelhos de amplificação sonora individual (AASI) são atualmente as próteses mais utilizadas para reabilitação de pessoas com deficiência auditiva. Conhecer a performance eletroacústica do AASI e equipará-las com as necessidades do indivíduo é um fator crítico para o sucesso da adaptação do AASI à necessidade do usuário. Procedimentos para avaliação da performance eletroacústica dos aparelhos são descritos pelas principais normas de avaliação de AASI que incluem a série IEC 60118, a qual é composta por 15 partes. A parte 0 apresenta procedimentos para a determinação das principais informações que devem constar na folha de dados, enquanto a parte 7 estabelece procedimentos e tolerâncias para avaliações de controle de qualidade. Já a parte 8 utiliza um manequim para simular a performance do AASI em um individuo e inclui ensaios para a análise das características direcionais. Entretanto, o desempenho dos AASI em indivíduos reais podem diferir significativamente dos obtidos através das técnicas da série IEC 60118. Em vista disso, a IEC 61669 estipula uma série de procedimentos para realização de ensaios em orelha real, que são fundamentais para o processo de adaptação do AASI. O presente trabalho tem por objetivo implementar e avaliar os resultados obtidos através dos procedimentos estabelecidos pelas normas supracitadas. Os requisitos das normas foram analisados e soluções em termos de equipamentos foram propostas, seguidas por uma análise de incerteza das grandezas medidas. A implementação da parte 0 foi comparada e validada com base nos resultados produzidos por um laboratório acreditado. Seis AASIs comerciais foram avaliados segundo as tolerâncias da parte 7 e apresentaram a maioria dos resultados dentro dos limites de aceitação. Os resultados da parte 8 mostraram-se contundentes com o tipo de AASI testado. Por fim, os ensaios segundo a IEC 61669 foram conduzidos no manequim através de um sistema comercial de testes. Na comparação entre os resultados da parte 8 com a IEC 61669 foram encontradas diferenças relevantes, provavelmente oriundas de problemas no acoplamento e colocação do microfone sonda. A implementação dessas normas viabiliza ao laboratório a condução de futuras investigações na área de AASI. Além disso, o trabalho estabelece de forma detalhada soluções que obedecem os requisitos estabelecidos na norma e detalhes acerca da implementação dos procedimentos das mesmas.<br>Abstract : Hearing aids are currently the most common device used for rehabilitation of people with hearing impairments. The hearing aids electroacoustic performance is of utmost importance for hearing care professionals to properly choose and adapt the device for a particular individual. The evaluation of electroacoustic performance of hearing aids are described by the hearing aids main standards, which includes the IEC 60118 series. This series is composed by 15 parts; part 0 provides procedures for the determination of the key information to be included in the data sheet, while part 7 establishes procedures and tolerances for quality control assessments. Part 8 uses a manikin to simulate the performance of hearing aids in an individual and includes tests to analyze directional characteristics. However, the hearing aid performance in real individuals may differ significantly from those obtained through the techniques described by IEC 60118. As a result, the IEC 61669 provides a set of procedures for performing tests in real ear, which are fundamental to hearing aids fitting process. This paper aims to describe the implementation process and analysis of results obtained through the procedures established by the standards previously cited. The standards' requirements have been raised and solutions in terms of equipment was proposed, followed by an uncertainty analysis of the measured quantities. The implementation of Part 0 was compared and validated based on the results produced by an accredited laboratory. Six commercial hearing aids were evaluated according to the tolerance on part 7 and most of the results were found acceptable. The results of part 8 proved to be conclusive with the type of hearing aids tested. Finally, the tests according to IEC 61669 were conducted on the manikin using a commercial test system. The comparison between results of Part 8 and IEC 61669 revealed relevant differences, probably from the coupling and placement of the probe microphone. The implementation of these standards enables the laboratory to conduct further investigations on hearing aids area. In addition, this work establishes solutions that meet the standards requirements and describes in details the implementation of the procedures.Cordioli, Júlio ApolinárioPaul, StephanUniversidade Federal de Santa CatarinaMasson, Zargos Neves2017-04-04T04:12:25Z2017-04-04T04:12:25Z2016info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis202 p.| il., grafs., tabs.application/pdf344642https://repositorio.ufsc.br/xmlui/handle/123456789/174436porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2017-04-04T04:12:25Zoai:repositorio.ufsc.br:123456789/174436Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732017-04-04T04:12:25Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Avaliação do desempenho de aparelhos de amplificação sonora individual com base em normas internacionais
title Avaliação do desempenho de aparelhos de amplificação sonora individual com base em normas internacionais
spellingShingle Avaliação do desempenho de aparelhos de amplificação sonora individual com base em normas internacionais
Masson, Zargos Neves
Engenharia mecânica
Distúrbios da audição
Aparelhos auditivos
Normas
Avaliação
title_short Avaliação do desempenho de aparelhos de amplificação sonora individual com base em normas internacionais
title_full Avaliação do desempenho de aparelhos de amplificação sonora individual com base em normas internacionais
title_fullStr Avaliação do desempenho de aparelhos de amplificação sonora individual com base em normas internacionais
title_full_unstemmed Avaliação do desempenho de aparelhos de amplificação sonora individual com base em normas internacionais
title_sort Avaliação do desempenho de aparelhos de amplificação sonora individual com base em normas internacionais
author Masson, Zargos Neves
author_facet Masson, Zargos Neves
author_role author
dc.contributor.none.fl_str_mv Cordioli, Júlio Apolinário
Paul, Stephan
Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Masson, Zargos Neves
dc.subject.por.fl_str_mv Engenharia mecânica
Distúrbios da audição
Aparelhos auditivos
Normas
Avaliação
topic Engenharia mecânica
Distúrbios da audição
Aparelhos auditivos
Normas
Avaliação
description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2016.
publishDate 2016
dc.date.none.fl_str_mv 2016
2017-04-04T04:12:25Z
2017-04-04T04:12:25Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv 344642
https://repositorio.ufsc.br/xmlui/handle/123456789/174436
identifier_str_mv 344642
url https://repositorio.ufsc.br/xmlui/handle/123456789/174436
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 202 p.| il., grafs., tabs.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1808651915252203520