Método para retrofit em sistemas de iluminação de hospitais públicos: estudo de caso no Hospital Público Regional de Betim

Detalhes bibliográficos
Autor(a) principal: Moreira, José Francisco Campos
Data de Publicação: 2012
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: http://repositorio.ufsc.br/xmlui/handle/123456789/94640
Resumo: Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2008
id UFSC_0ba49a3d0ca6fce472b4a538dc0288fc
oai_identifier_str oai:repositorio.ufsc.br:123456789/94640
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Método para retrofit em sistemas de iluminação de hospitais públicos: estudo de caso no Hospital Público Regional de BetimEngenharia civilHospitaisIluminaçãoIluminação naturalAvaliaçãoEnergia eletrica -ConsumoDissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2008As dificuldades históricas da oferta de serviços de boa qualidade e em quantidade suficiente na área da saúde pública no Brasil têm sempre o discurso da falta de recursos financeiros. Nota-se com frequência, entretanto, o mau uso dos recursos públicos, seja na concepção e construção de edificações com pouca ou nenhuma preocupação com a eficiência energética, seja com uma gestão mal preparada, que não consegue avaliar, preparar e conscientizar os ocupantes para a questão da conservação de energia. Neste sentido, este trabalho tem como objetivo propor um método para a análise da viabilidade técnica e econômica de se implementar um retrofit no sistema de iluminação de hospitais públicos, com vistas a torná-lo energeticamente eficiente e ao mesmo tempo proporcionar maior conforto luminoso a todos os usuários. A metodologia proposta compreende a avaliação da atual situação com relação à quantidade e qualidade da iluminação em diversos ambientes de um hospital. Compreende também a avaliação dos usos finais, avaliação da representatividade do uso final com iluminação em face do consumo total do estabelecimento e avaliação da possibilidade de se implementar um retrofit, em função da economia de energia resultante com o uso de equipamentos eficientes. Para tal, realiza-se uma pesquisa de mercado sobre a disponibilidade de equipamentos eficientes, com base em critérios de qualidade e de menor custo. A partir da escolha dos produtos elaboram-se novos projetos luminotécnicos, os quais levam em conta tanto a quantidade de iluminação preconizada pelas normas quanto à qualidade da mesma, através do estudo de luminância, temperatura de cor correlata e índice de reprodução de cores, adequados a cada situação. Os cálculos destes projetos são subsidiados pelo software Dialux®, versão 4.7.5. De forma a se verificar a viabilidade econômica determina-se alguns indicadores, como o tempo de retorno (payback time) do retrofit, a taxa interna de retorno, a relação benefício-custo e valor presente líquido. O estudo é encerrado com a análise da possibilidade de utilização da iluminação natural como forma de proporcionar economias adicionais de energia elétrica. A metodologia foi aplicada no Hospital Público Regional de Betim/MG, para o qual verificou-se a possibilidade de redução em cerca de 59% no consumo de energia com iluminação, que resultaria na diminuição em cerca de 14% na conta de energia do estabelecimento. Caso o retrofit seja efetivado, os estudos apontam para um payback time ocorrendo entre os meses 13 e 14 após a implantação.The historical difficulties with the provision of services of good quality and sufficient quantity in the area of public health in Brazil has always met the lack of financial resources. However, the misuse of public financial resources both in design and construction of buildings, with little or no concern about energy efficiency, is often noted, as well as illprepared management that cannot make the occupants aware of the issue of energy conservation. Thus, this work aims to propose a methodology for technical and investment feasibility analysis of lighting system retrofit for public hospitals, in order to improve the lighting system energy efficiency and the visual comfort to all users. The proposed methodology includes the evaluation of the current situation regarding the amount and quality of lighting in various areas of a hospital. Also includes the evaluation of energy end-uses, assesses the representativeness of the lighting end-use in comparison to the total consumption of the hospital and evaluates the possibility of implementing a retrofit, according to the energy savings obtained by using energy-efficient lighting equipment. A market research on the availability of energy-efficient equipment, based on criteria of quality and lower cost, was performed. Thus, a new lighting design, which takes into account the illuminance levels proposed by the Brazilian standards, a study of luminances, correlated temperatures and colour rendering index, was performed. The Dialux ® computer programme, version 4.7.5, was used for the lighting design. The investment feasibility analysis was performed by calculating some indicators such as payback time, internal rate of return, benefit to cost ratio and net present value. The study also considered an analysis of the possible use of daylight as a way of promoting additional energy savings. The methodology was applied to the Regional Public Hospital of Betim, located in the state of Minas Gerais, Brazil. The potential for lighting energy savings was estimated as 59% while the total energy savings would be about 14%. As for the investment feasibility analysis, a payback time of 13-14 months was found.Ghisi, EnedirUniversidade Federal de Santa CatarinaMoreira, José Francisco Campos2012-10-25T13:56:23Z2012-10-25T13:56:23Z2012-10-25T13:56:23Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis311 p.| il., grafs., tabs.application/pdf281333http://repositorio.ufsc.br/xmlui/handle/123456789/94640porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2013-05-05T05:51:29Zoai:repositorio.ufsc.br:123456789/94640Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732013-05-05T05:51:29Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Método para retrofit em sistemas de iluminação de hospitais públicos: estudo de caso no Hospital Público Regional de Betim
title Método para retrofit em sistemas de iluminação de hospitais públicos: estudo de caso no Hospital Público Regional de Betim
spellingShingle Método para retrofit em sistemas de iluminação de hospitais públicos: estudo de caso no Hospital Público Regional de Betim
Moreira, José Francisco Campos
Engenharia civil
Hospitais
Iluminação
Iluminação natural
Avaliação
Energia eletrica -
Consumo
title_short Método para retrofit em sistemas de iluminação de hospitais públicos: estudo de caso no Hospital Público Regional de Betim
title_full Método para retrofit em sistemas de iluminação de hospitais públicos: estudo de caso no Hospital Público Regional de Betim
title_fullStr Método para retrofit em sistemas de iluminação de hospitais públicos: estudo de caso no Hospital Público Regional de Betim
title_full_unstemmed Método para retrofit em sistemas de iluminação de hospitais públicos: estudo de caso no Hospital Público Regional de Betim
title_sort Método para retrofit em sistemas de iluminação de hospitais públicos: estudo de caso no Hospital Público Regional de Betim
author Moreira, José Francisco Campos
author_facet Moreira, José Francisco Campos
author_role author
dc.contributor.none.fl_str_mv Ghisi, Enedir
Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Moreira, José Francisco Campos
dc.subject.por.fl_str_mv Engenharia civil
Hospitais
Iluminação
Iluminação natural
Avaliação
Energia eletrica -
Consumo
topic Engenharia civil
Hospitais
Iluminação
Iluminação natural
Avaliação
Energia eletrica -
Consumo
description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2008
publishDate 2012
dc.date.none.fl_str_mv 2012-10-25T13:56:23Z
2012-10-25T13:56:23Z
2012-10-25T13:56:23Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv 281333
http://repositorio.ufsc.br/xmlui/handle/123456789/94640
identifier_str_mv 281333
url http://repositorio.ufsc.br/xmlui/handle/123456789/94640
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 311 p.| il., grafs., tabs.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1808651949089751040