Análise da influência do tratamento a plasma nas propriedades da matriz de regeneração dérmica
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFSC |
Texto Completo: | https://repositorio.ufsc.br/handle/123456789/220056 |
Resumo: | Dissertação (mestrado) - Universidade Federal de Santa Catarina, Campus Joinville, Programa de Pós-Graduação em Engenharia e Ciências Mecânicas, Joinville, 2019 |
id |
UFSC_14663c0c6fad67cc4bdbdd83a053f331 |
---|---|
oai_identifier_str |
oai:repositorio.ufsc.br:123456789/220056 |
network_acronym_str |
UFSC |
network_name_str |
Repositório Institucional da UFSC |
repository_id_str |
2373 |
spelling |
Análise da influência do tratamento a plasma nas propriedades da matriz de regeneração dérmicaEngenharia mecânicaMateriais biocompatíveisBiopolímerosColágenoDissertação (mestrado) - Universidade Federal de Santa Catarina, Campus Joinville, Programa de Pós-Graduação em Engenharia e Ciências Mecânicas, Joinville, 2019Dados oficiais do Ministério da Saúde, do Brasil, indicam que ocorrem cerca de um milhão de lesões dérmicas por ano, o que evidencia a necessidade do estudo de métodos de regeneração dérmica, visando a melhorar a qualidade de vida, uma vez que, pessoas morrem direta ou indiretamente por infecções e/ou inflamações em queimaduras. Neste estudo a matriz de regeneração dérmica utilizada é composta por colágeno do tipo I e glicosaminoglicanos, e de uma fina camada de silicone para proteger a estrutura viva, que é aplicada no tecido lesionado. Um dos tratamentos citados inclui os processos a plasma, que têm sido utilizados para gerar espécies químicas, capazes de eliminar contaminantes e catalisar reações atribuídas a biocompatibilidade. Considerando o exposto, no presente trabalho, é apresentado o estudo da influência de diferentes parâmetros do tratamento por plasma de argônio, em membrana polimérica, utilizadas no segmento médico e com a finalidade de gerar sítios ativos, o que auxilia na biocompatibilidade. A matriz dérmica (Integra?) utilizada neste estudo foi liofilizadas para a retirada da água e, posteriormente, foram tratadas por plasma de argônio, para duas configurações experimentais diferentes. Amostras denominadas 1, 2 e 3 foram tratadas por 120, 150 e 60s, respectivamente, com plasma de argônio composto por 50 sccm de fluxo de massa e 3,4 torr de pressão de trabalho, gerados por 450 V DC e corrente de 0,32 A. As amostras denominadas 3, 4 e 6 foram tratadas por 60, 120 e 180s, respectivamente, com plasma de argônio, composto por fluxo de massa de 20 sccm e pressão de trabalho de 9,7 torr, geradas por 400 V DC e corrente de 0,27 A. As caracterizações foram conduzidas pelo modelo MEV Jeol JSM-6390LV, o modelo XPS Thermo Scientific K-Alpha e o modelo TAC TA Instruments Q20 para avaliar morfologia, propriedades químicas e estabilidade térmica, respectivamente. Os espectros de XPS foram realizados para caracterizar a quantidade de oxigênio presente na amostra. Os resultados desde estudo mostram que o plasma de argônio promove modificações estruturais negativas para o crescimento celular, houve mobilidade das cadeias, fechando parcialmente os poros. Considerando o exposto, no presente trabalho, é apresentado o estudo da influência de diferentes parâmetros do tratamento por plasma de argônio, em membrana polimérica, utilizadas no segmento médico e com a finalidade de gerar sítios ativos, o que auxilia na biocompatibilidade.Abstract: Official data from the Brazilian Ministry of Health indicate that there are around one million skin lesions per year, which highlights the need to study dermal regeneration methods to improve the quality of life, since people die directly or indirectly from infections and / or inflammations in burns. In this study the dermal regeneration matrix used is composed of type I collagen and glycosaminoglycans, and a thin layer of silicone to protect the living structure, which is applied to the injured tissue. One of the treatments cited includes plasma processes, which have been used to generate chemical species capable of eliminating contaminants and catalyzing reactions attributed to biocompatibility. Considering the above, in the present work, the study of the influence of different parameters of argon plasma treatment in polymeric membrane, used in the medical segment and with the purpose of generating active sites, is presented, which assists biocompatibility. The dermal matrix (Integra ?) used in this study was lyophilized for water withdrawal and subsequently treated by argon plasma for two different experimental configurations. Samples denominated 1, 2 and 3 were treated by 120, 150 and 60s, respectively, with argon plasma composed of 50 sccm of mass flow and 3.4 torr of working pressure, generated by 450 V DC and current of 0, The samples named 3, 4 and 6 were treated with 60, 120 and 180s, respectively, with argon plasma, composed of mass flow of 20 sccm and working pressure of 9.7 torr, generated by 400 V DC and current of 0.27 A. The characterizations were conducted by Jeol JSM-6390LV MEV model, Thermo Scientific K-Alpha XPS model and TA Instruments Q20 TAC model to evaluate morphology, chemical properties and thermal stability, respectively. The XPS spectra were performed to characterize the amount of oxygen present in the sample. The results from the study show that argon plasma promotes structural modifications that are negative for cell growth, there was motility of the chains, partially closing the pores. Considering the above, in the present work, the study of the influence of different parameters of argon plasma treatment in polymeric membrane, used in the medical segment and with the purpose of generating active sites, is presented, which assists biocompatibility.Soethe, Viviane LilianDuarte, Diego AlexandreUniversidade Federal de Santa CatarinaGonçalves, Miriam Fátima2021-02-11T22:39:40Z2021-02-11T22:39:40Z2019info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis81 p.| il., gráfs., tabs.application/pdf363524https://repositorio.ufsc.br/handle/123456789/220056porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2021-02-11T22:39:40Zoai:repositorio.ufsc.br:123456789/220056Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732021-02-11T22:39:40Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false |
dc.title.none.fl_str_mv |
Análise da influência do tratamento a plasma nas propriedades da matriz de regeneração dérmica |
title |
Análise da influência do tratamento a plasma nas propriedades da matriz de regeneração dérmica |
spellingShingle |
Análise da influência do tratamento a plasma nas propriedades da matriz de regeneração dérmica Gonçalves, Miriam Fátima Engenharia mecânica Materiais biocompatíveis Biopolímeros Colágeno |
title_short |
Análise da influência do tratamento a plasma nas propriedades da matriz de regeneração dérmica |
title_full |
Análise da influência do tratamento a plasma nas propriedades da matriz de regeneração dérmica |
title_fullStr |
Análise da influência do tratamento a plasma nas propriedades da matriz de regeneração dérmica |
title_full_unstemmed |
Análise da influência do tratamento a plasma nas propriedades da matriz de regeneração dérmica |
title_sort |
Análise da influência do tratamento a plasma nas propriedades da matriz de regeneração dérmica |
author |
Gonçalves, Miriam Fátima |
author_facet |
Gonçalves, Miriam Fátima |
author_role |
author |
dc.contributor.none.fl_str_mv |
Soethe, Viviane Lilian Duarte, Diego Alexandre Universidade Federal de Santa Catarina |
dc.contributor.author.fl_str_mv |
Gonçalves, Miriam Fátima |
dc.subject.por.fl_str_mv |
Engenharia mecânica Materiais biocompatíveis Biopolímeros Colágeno |
topic |
Engenharia mecânica Materiais biocompatíveis Biopolímeros Colágeno |
description |
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Campus Joinville, Programa de Pós-Graduação em Engenharia e Ciências Mecânicas, Joinville, 2019 |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019 2021-02-11T22:39:40Z 2021-02-11T22:39:40Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
363524 https://repositorio.ufsc.br/handle/123456789/220056 |
identifier_str_mv |
363524 |
url |
https://repositorio.ufsc.br/handle/123456789/220056 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
81 p.| il., gráfs., tabs. application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFSC instname:Universidade Federal de Santa Catarina (UFSC) instacron:UFSC |
instname_str |
Universidade Federal de Santa Catarina (UFSC) |
instacron_str |
UFSC |
institution |
UFSC |
reponame_str |
Repositório Institucional da UFSC |
collection |
Repositório Institucional da UFSC |
repository.name.fl_str_mv |
Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC) |
repository.mail.fl_str_mv |
|
_version_ |
1808652006181568512 |