Tratamento terciário de esgoto sanitário através de processos oxidativos avançados para obtenção de água de reúso

Detalhes bibliográficos
Autor(a) principal: Vargas, Gean Delise Leal Pasquali
Data de Publicação: 2008
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: http://repositorio.ufsc.br/xmlui/handle/123456789/91782
Resumo: Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Química.
id UFSC_282fbf42fb5b2e17660f0a5762832218
oai_identifier_str oai:repositorio.ufsc.br:123456789/91782
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Tratamento terciário de esgoto sanitário através de processos oxidativos avançados para obtenção de água de reúsoEngenharia quimicaEsgotosAgua -ReutilizaçãoAgua -Purificacao - OxidacaoTese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Química.Atualmente a escassez de água tem se tornado um problema real e presente em âmbito mundial, devido ao aumento constante na demanda deste recurso em relação a sua oferta. Neste contexto, têm sido propostas alternativas para viabilizar a reutilização de águas com qualidade inferior, como as de esgotos domésticos tratados, para usos menos restritivos, reduzindo assim o consumo de água potável e disponibilizando-a para fins mais nobres. Uma das maiores limitações com relação à reutilização de águas provenientes de esgoto sanitário tratado é a presença de microrganismos patogênicos. O uso de cloro e seus derivados tem sido descartado, devido à formação de subprodutos mutagênicos e carcinogênicos. Outros desinfetantes alternativos como a radiação UV, H2O2, H2O2/UV e o ozônio são considerados menos perigosos. Peróxido de hidrogênio é um oxidante forte, mas a oxidação somente com peróxido de hidrogênio não é efetiva no tratamento de compostos refratários devido às lentas cinéticas de oxidação. Assim, é necessário combinar o uso de H2O2 com luz UV ou com sais de ferro. A oxidação catalítica em fase líquida com H2O2 tem se mostrado um processo eficiente na destruição de diversos compostos orgânicos. Contudo, a estabilidade do catalisador é ainda um problema a ser contornado, uma vez que a fase ativa, constituída por óxidos de ferro, pode ser lixiviada para a fase líquida e o catalisador perde sua atividade. O objetivo deste trabalho é avaliar o desempenho do processo Fenton heterogêneo, em reator de leito fixo, na destruição de Coliformes totais, remoção de sólidos suspensos e de sólidos dissolvidos como método de tratamento terciário de águas servidas. Foi utilizado um compósito constituído de óxidos de ferro depositados sobre carvão mineral como catalisador heterogêneo. O efeito da concentração de H2O2 e do tempo de residência no reator foram avaliados. Foi proposto um mecanismo de reação que descreve o processo de oxidação catalítica e não catalítica por peróxido de hidrogênio. A cinética de inativação não catalítica de Coliformes foi avaliada em reator descontínuo e obedeceu o modelo de Hom modificado. Na presença do catalisador heterogêneo a inativação de coliformes é resultado das reações catalíticas e não catalíticas. O catalisador sólido possui capacidade adsortiva desprezível. Testes realizados em reator de leito fixo em escala de laboratório e em escala piloto mostraram que a remoção de Coliformes é resultado da retenção física entre as partículas, e pelas reações homogêneas e heterogêneas de peroxidação. Os resultados também mostram que o catalisador é eficiente apresentando alta estabilidade, acelerando a decomposição do H2O2, resultando assim em uma elevada remoção dos parâmetros de controle de qualidade da água. Currently the water scarcity has become a real and present problem worldwide, due to the constant increase in the demand of this resource. Alternatives to make possible the reuse of water with inferior quality for less restrictive uses, as treated domestic sewer have been proposed, thus reducing the drinking water consumption and increasing its availability for nobler uses. One of the most important limitations for reuse of treated sanitary sewer is the presence of pathogenic microorganisms. The use of chlorine and its derivatives has been discouraged, due to the formation of mutagenic and carcinogenic by-products. Other alternative disinfectants, such as UV radiation, H2O2, H2O2/UV and ozone are less dangerous and deserve technical and economic attention. Hydrogen peroxide is a strong oxidant, but the oxidation with hydrogen peroxide is not effective in the decomposition of refractory compounds, since the oxidation rate is too low. Thus, it is necessary to combine the use of H2O2 with UV light or iron salts. The liquid phase catalytic oxidation with H2O2 has shown to be an efficient process to decompose several organic compounds. However, the stability of the catalyst is still a problem to be overcome; since the active phase is composed by iron oxides that are easily leached to the liquid phase causing the loss of catalyst is activity. The objective of this work is to evaluate the performance of heterogeneous Fenton process in a fixed bed reactor, to eliminate total coliforms, and to remove dissolved solid and suspended solid as a method of tertiary served water treatment. A new composite of iron oxides deposited on mineral coal was used as catalyst. The effect of the concentration of H2O2 and the time of residence in the reactor were evaluated. A reaction mechanism that describes the catalytic process and non-catalytic oxidation for hydrogen peroxide was proposed. The kinetics of catalytic and non-catalytic inactivation of colifoms was evaluated in batch and continuous reactors. The non-catalytic coliforms and E. coli inactivation followed the modified Hom mechanism. In the presence of the solid catalyst the inactivation of E.coli is a result of catalytic and non-catalytic reactions but the adsorption capacity of E.coli is negligible. The experimental tests performed in fixed bed reactor in laboratory and pilot scale showed that the E.coli and total coliforms removal was a result of physical retention between the particles of the catalyst, homogeneous and heterogeneous reactions. The catalyst was efficient to destroy E.coli and total coliforms presenting high stability and increase of decomposition of the H2O2 resulting in a high removal of parameters of the water quality control.Florianópolis, SCMoreira, Regina de Fatima Peralta MunizJose, Humberto JorgeUniversidade Federal de Santa CatarinaVargas, Gean Delise Leal Pasquali2012-10-24T02:27:49Z2012-10-24T02:27:49Z20082008info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisxx, 264 f.| il., grafs., tabs.application/pdf249266http://repositorio.ufsc.br/xmlui/handle/123456789/91782porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2013-05-01T16:22:36Zoai:repositorio.ufsc.br:123456789/91782Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732013-05-01T16:22:36Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Tratamento terciário de esgoto sanitário através de processos oxidativos avançados para obtenção de água de reúso
title Tratamento terciário de esgoto sanitário através de processos oxidativos avançados para obtenção de água de reúso
spellingShingle Tratamento terciário de esgoto sanitário através de processos oxidativos avançados para obtenção de água de reúso
Vargas, Gean Delise Leal Pasquali
Engenharia quimica
Esgotos
Agua -
Reutilização
Agua -
Purificacao - Oxidacao
title_short Tratamento terciário de esgoto sanitário através de processos oxidativos avançados para obtenção de água de reúso
title_full Tratamento terciário de esgoto sanitário através de processos oxidativos avançados para obtenção de água de reúso
title_fullStr Tratamento terciário de esgoto sanitário através de processos oxidativos avançados para obtenção de água de reúso
title_full_unstemmed Tratamento terciário de esgoto sanitário através de processos oxidativos avançados para obtenção de água de reúso
title_sort Tratamento terciário de esgoto sanitário através de processos oxidativos avançados para obtenção de água de reúso
author Vargas, Gean Delise Leal Pasquali
author_facet Vargas, Gean Delise Leal Pasquali
author_role author
dc.contributor.none.fl_str_mv Moreira, Regina de Fatima Peralta Muniz
Jose, Humberto Jorge
Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Vargas, Gean Delise Leal Pasquali
dc.subject.por.fl_str_mv Engenharia quimica
Esgotos
Agua -
Reutilização
Agua -
Purificacao - Oxidacao
topic Engenharia quimica
Esgotos
Agua -
Reutilização
Agua -
Purificacao - Oxidacao
description Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Química.
publishDate 2008
dc.date.none.fl_str_mv 2008
2008
2012-10-24T02:27:49Z
2012-10-24T02:27:49Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv 249266
http://repositorio.ufsc.br/xmlui/handle/123456789/91782
identifier_str_mv 249266
url http://repositorio.ufsc.br/xmlui/handle/123456789/91782
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv xx, 264 f.| il., grafs., tabs.
application/pdf
dc.publisher.none.fl_str_mv Florianópolis, SC
publisher.none.fl_str_mv Florianópolis, SC
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1808652398320680960