Avaliação dos efeitos da conversão do plasma sobre reatividade e estabilidade de painéis sorológicos para diagnóstico da sífilis

Detalhes bibliográficos
Autor(a) principal: Machado, Hanalydia de Melo
Data de Publicação: 2017
Tipo de documento: Trabalho de conclusão de curso
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/xmlui/handle/123456789/176846
Resumo: TCC(graduação) - Universidade Federal de Santa Catarina. Centro de Ciências Biológicas. Biologia.
id UFSC_3f3b3eeec8c6f9ec1106a1be09db425e
oai_identifier_str oai:repositorio.ufsc.br:123456789/176846
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Avaliação dos efeitos da conversão do plasma sobre reatividade e estabilidade de painéis sorológicos para diagnóstico da sífilisSífilisDiagnósticoControle da qualidadeSyphilisDiagnosisQuality controlTCC(graduação) - Universidade Federal de Santa Catarina. Centro de Ciências Biológicas. Biologia.Os casos de sífilis vêm aumentando no mundo, no Brasil e em Santa Catarina. A OMS estima que 937 mil pessoas são infectadas a cada ano no país. Em Santa Catarina foram registrados 5.427 novos casos de sífilis em 2015, um aumento de quase 50% comparado com o total notificado em 2014. O diagnóstico da sífilis é baseado nas manifestações clínicas, pesquisa direta do patógeno e testes sorológicos. Para que os testes realizados no diagnóstico da sífilis possuam confiabilidade no seu resultado, é necessário que os laboratórios e os serviços que realizam o diagnóstico participem de programas de controle de qualidade. A unidade de saúde ou laboratório deve garantir que no processo analítico os resultados atendam aos critérios de qualidade exigidos por lei. O presente trabalho pretende avaliar os efeitos da conversão do plasma em soro e a adição de azida de sódio como conservante. A desfibrinação transforma o plasma, de bolsas de doadores, em soro, por meio da recuperação da cascata de coagulação com trombina e cálcio. Além disso, o trabalho pretende verificar possíveis alterações na reatividade das amostras submetidas a diferentes temperaturas de armazenamento e ciclos de congelamento e descongelamento durante 90 dias. Foram utilizadas duas bolsas reagentes para sífilis e uma bolsa não reagente. Após o tratamento das bolsas, as amostras foram separadas em 4 grupos (G): G1: Plasma sem azida de sódio, G2: Soro sem de azida de sódio, G3: Plasma com azida de sódio, G4: Soro com azida de sódio. Foram distribuídas alíquotas desses quatro grupos em cinco condições de armazenamento: 2 a 8ºC, 30ºC, -20ºC (duas alíquotas) e -80ºC. Uma das alíquotas armazenadas em -20ºC foi descongelada em banho-maria (37ºC) por 30 minutos e a outra foi descongelada em temperatura ambiente de laboratório (20 a 26ºC). A partir do armazenamento das alíquotas em cada condição, foram realizados 12 ciclos de testagem, um a cada sete dias, totalizando 12 semanas. As amostras foram avaliadas com um teste rápido treponêmico (Bioeasy) e um teste não-treponêmico (RPR Wama), a fim de comparar os tratamentos realizados nas bolsas de plasma e os efeitos das diferentes condições às quais as amostras foram expostas, por meio da comparação dos resultados da reatividade dessas alíquotas nos respectivos testes. Esse estudo demonstrou que apesar do tempo de armazenamento e constante manipulação das alíquotas, os resultados obtidos na bolsa 1 (reagente) não demonstram diferença entre a reatividade inicial e final nos testes realizados. Já os resultados relacionados à bolsa 2 (reagente) tiveram diferenças nos testes não-treponêmicos e principalmente nas alíquotas armazenadas na temperatura de 30°C, que também sofreram alterações no teste treponêmico, porém, as alíquotas dessa bolsa armazenadas em -20°C não sofreram alterações em sua reatividade.Syphilis cases have been increasing in the world, in Brazil and in Santa Catarina. WHO estimates that 937 thousand people are infected each year in the country. In Santa Catarina, 5.427 new cases of syphilis were registered in 2015, an increase of almost 50% compared to the number of cases reported in 2014. The diagnosis of syphilis is based on clinical manifestations, direct pathogen research and serological tests. In order for the tests performed in the diagnosis of syphilis to have reliability in their results, the laboratories and services that perform the diagnosis must participate in quality control programs. The health unit or laboratory must ensure that in the analytical process the results meet the quality criteria required by law. The present work intends to evaluate the effects of the conversion of plasma to serum and the addition of sodium azide as a preservative. Defibrination transforms plasma, from donor bags, into serum by means of recovery the plasma coagulation cascade with thrombin and calcium. In addition, the work intends to verify possible changes in the reactivity of samples submitted to different storage temperatures and freezing and thawing cycles for 90 days. Two different syphilis reagent bags and one non-reagent bag were used. After treatment of this bags, the samples were separated into 4 groups (G): G1: Plasma without sodium azide, G2: Serum without sodium azide, G3: Plasma with sodium azide, G4: Serum with sodium azide. Aliquots of these four groups were distributed under five storage conditions: 2-8°C, 30°C, -20°C (two aliquots) and -80°C. One of the aliquots stored at -20°C was thawed in a warm bath (37 °C) for 30 minutes. The remainder was thawed at laboratory room temperature (20 to 26 °C). From the storage of the aliquots in each condition, 12 cycles of testing were performed, one every seven days, totaling 12 weeks. The samples were evaluated with a rapid treponemal test (Bioeasy) and a non-treponemal test (RPR Wama), in order to compare the treatments performed in the plasma bag and the effects of the different conditions to which samples were exposed, by means of the comparison of the reactivity results of these rates in the respective tests. This study demonstrated that despite storage time and constant manipulation of aliquots, the results obtained in bag 1 (reagent) did not show any difference between initial and final reactivity in the tests performed. However, the results related to bag 2 (reagent) had differences in the non-treponemal tests, mainly in the aliquots stored at 30°C, which also underwent alterations in the treponemal test, but the aliquots of this bag stored at -20°C did not change this reactivity.Florianópolis, SC.Bazzo, Maria LuizaUniversidade Federal de Santa CatarinaMachado, Hanalydia de Melo2017-06-30T19:06:05Z2017-06-30T19:06:05Z2017-06-20info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis70 f.application/pdfhttps://repositorio.ufsc.br/xmlui/handle/123456789/176846porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2017-06-30T19:06:05Zoai:repositorio.ufsc.br:123456789/176846Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732017-06-30T19:06:05Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Avaliação dos efeitos da conversão do plasma sobre reatividade e estabilidade de painéis sorológicos para diagnóstico da sífilis
title Avaliação dos efeitos da conversão do plasma sobre reatividade e estabilidade de painéis sorológicos para diagnóstico da sífilis
spellingShingle Avaliação dos efeitos da conversão do plasma sobre reatividade e estabilidade de painéis sorológicos para diagnóstico da sífilis
Machado, Hanalydia de Melo
Sífilis
Diagnóstico
Controle da qualidade
Syphilis
Diagnosis
Quality control
title_short Avaliação dos efeitos da conversão do plasma sobre reatividade e estabilidade de painéis sorológicos para diagnóstico da sífilis
title_full Avaliação dos efeitos da conversão do plasma sobre reatividade e estabilidade de painéis sorológicos para diagnóstico da sífilis
title_fullStr Avaliação dos efeitos da conversão do plasma sobre reatividade e estabilidade de painéis sorológicos para diagnóstico da sífilis
title_full_unstemmed Avaliação dos efeitos da conversão do plasma sobre reatividade e estabilidade de painéis sorológicos para diagnóstico da sífilis
title_sort Avaliação dos efeitos da conversão do plasma sobre reatividade e estabilidade de painéis sorológicos para diagnóstico da sífilis
author Machado, Hanalydia de Melo
author_facet Machado, Hanalydia de Melo
author_role author
dc.contributor.none.fl_str_mv Bazzo, Maria Luiza
Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Machado, Hanalydia de Melo
dc.subject.por.fl_str_mv Sífilis
Diagnóstico
Controle da qualidade
Syphilis
Diagnosis
Quality control
topic Sífilis
Diagnóstico
Controle da qualidade
Syphilis
Diagnosis
Quality control
description TCC(graduação) - Universidade Federal de Santa Catarina. Centro de Ciências Biológicas. Biologia.
publishDate 2017
dc.date.none.fl_str_mv 2017-06-30T19:06:05Z
2017-06-30T19:06:05Z
2017-06-20
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://repositorio.ufsc.br/xmlui/handle/123456789/176846
url https://repositorio.ufsc.br/xmlui/handle/123456789/176846
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 70 f.
application/pdf
dc.publisher.none.fl_str_mv Florianópolis, SC.
publisher.none.fl_str_mv Florianópolis, SC.
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1808652357679972352