Conforto térmico humano em edificações de escritórios localizadas no clima subtropical úmido de Florianópolis/SC

Detalhes bibliográficos
Autor(a) principal: Rupp, Ricardo Forgiarini
Data de Publicação: 2018
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/handle/123456789/191072
Resumo: Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2018.
id UFSC_5f465a99ed6e3651319f261b2081e443
oai_identifier_str oai:repositorio.ufsc.br:123456789/191072
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Conforto térmico humano em edificações de escritórios localizadas no clima subtropical úmido de Florianópolis/SCEngenharia civilConforto térmicoEscritóriosTese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2018.O objetivo deste trabalho é estudar a percepção térmica de ocupantes nos diferentes modos de operação de edificações de escritórios com ventilação híbrida e com sistema central de condicionamento artificial, localizados no clima subtropical úmido de Florianópolis/SC. Estudos de campo sobre conforto térmico foram realizados durante dois anos em quatro edificações de escritórios localizadas em Florianópolis. Três edificações operaram com a estratégia de ventilação híbrida, equipadas com sistema de ar-condicionado para resfriamento e janelas operáveis, ambos controlados pelos ocupantes de acordo com suas preferências. A quarta edificação operou com sistema central de ar-condicionado. Por meio de estações microclimáticas foram realizadas medições ambientais no mesmo local e ao mesmo tempo em que questionários de conforto térmico foram aplicados. Os estudos de campo, realizados nas quatro edificações e em todas as estações do ano, resultaram em mais de 7500 respostas aos questionários, associadas a variáveis ambientais e humanas. Os dados coletados foram analisados estatisticamente. Foram realizadas comparações entre as respostas subjetivas dos usuários e os modelos analítico e adaptativo da ASHRAE 55. Devido aos diferentes modos de operação das edificações com ventilação híbrida, verificou-se a necessidade de um modelo de conforto térmico específico para este tipo de edificação e modelos de conforto térmico adaptativo foram desenvolvidos para o modo de ventilação natural e durante a operação do sistema de ar-condicionado. Além disso, investigou-se a relação entre diferentes variáveis contextuais, como idade, gênero, peso e altura, e a percepção de conforto térmico dos usuários. As principais conclusões desta tese são: 1) o modo de operação atuante em edificações de escritórios com ventilação híbrida e com sistema central de ar-condicionado influencia na percepção de conforto térmico dos ocupantes, 2) não se encontrou evidências para justificar o desenvolvimento de um modelo adaptativo de conforto térmico específico para as edificações com ventilação híbrida. Os usuários das edificações com ventilação híbrida, operando no modo de ventilação natural, adaptaram-se às variações de temperatura interna, de acordo com a teoria de conforto térmico adaptativo; durante a operação do sistema de ar-condicionado os ocupantes estiveram desconectados do clima exterior, 3) diferentes grupos de pessoas requerem diferentes condições térmicas para sentirem-se em conforto térmico.Abstract : The objective of this work is to study occupant s thermal perception in the different modes of operation of mixed-mode and centralized air-conditioned office buildings located in the humid subtropical climate of Florianópolis/SC. Field studies on thermal comfort were conducted during two years in four office buildings located in Florianópolis. Three buildings operated with a mixed-mode strategy and were equipped with air-conditioning systems for cooling and operable windows, both controlled by users according to their preferences. The other building operated with a centralized air-conditioning system. Environmental variables were measured using microclimate instruments at the same location and time that thermal comfort questionnaires were collected. The field studies performed in the four buildings over the four seasons resulted in more than 7,500 questionnaire responses associated to environmental and human variables. The data collected were statistically analysed. Comparisons between user s subjective responses and analytical and adaptive models of ASHRAE 55 were carried out. Due to the different operation modes of the mixed-mode buildings, it was verified the need for a specific thermal comfort model for this type of building and adaptive thermal comfort models were developed for the natural ventilation mode and during the operation of the air-conditioning system. Furthermore, the relationship between different contextual variables, such as age, gender, weight and height, and occupant s thermal comfort perception was also investigated. The main conclusions obtained from this thesis are: 1) the operating mode in mixed-mode and in centralized air-conditioned office buildings influences occupant s thermal comfort perception, 2) no evidence was found to justify the development of an adaptive model of thermal comfort specific for mixed-mode buildings. The users of the mixed-mode buildings operating in the natural ventilation mode adapted to the indoor temperature variations, according to the adaptive thermal comfort theory; during the operation of the air-conditioning system the occupants were disconnected from the outdoor climate, 3) different groups of people require different thermal conditions to be in thermal comfort.Ghisi, EnedirDear, Richard deUniversidade Federal de Santa CatarinaRupp, Ricardo Forgiarini2018-11-03T04:05:57Z2018-11-03T04:05:57Z2018info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis289 p.| il., gráfs., tabs.application/pdf354510https://repositorio.ufsc.br/handle/123456789/191072porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2018-11-03T04:05:57Zoai:repositorio.ufsc.br:123456789/191072Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732018-11-03T04:05:57Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Conforto térmico humano em edificações de escritórios localizadas no clima subtropical úmido de Florianópolis/SC
title Conforto térmico humano em edificações de escritórios localizadas no clima subtropical úmido de Florianópolis/SC
spellingShingle Conforto térmico humano em edificações de escritórios localizadas no clima subtropical úmido de Florianópolis/SC
Rupp, Ricardo Forgiarini
Engenharia civil
Conforto térmico
Escritórios
title_short Conforto térmico humano em edificações de escritórios localizadas no clima subtropical úmido de Florianópolis/SC
title_full Conforto térmico humano em edificações de escritórios localizadas no clima subtropical úmido de Florianópolis/SC
title_fullStr Conforto térmico humano em edificações de escritórios localizadas no clima subtropical úmido de Florianópolis/SC
title_full_unstemmed Conforto térmico humano em edificações de escritórios localizadas no clima subtropical úmido de Florianópolis/SC
title_sort Conforto térmico humano em edificações de escritórios localizadas no clima subtropical úmido de Florianópolis/SC
author Rupp, Ricardo Forgiarini
author_facet Rupp, Ricardo Forgiarini
author_role author
dc.contributor.none.fl_str_mv Ghisi, Enedir
Dear, Richard de
Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Rupp, Ricardo Forgiarini
dc.subject.por.fl_str_mv Engenharia civil
Conforto térmico
Escritórios
topic Engenharia civil
Conforto térmico
Escritórios
description Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2018.
publishDate 2018
dc.date.none.fl_str_mv 2018-11-03T04:05:57Z
2018-11-03T04:05:57Z
2018
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv 354510
https://repositorio.ufsc.br/handle/123456789/191072
identifier_str_mv 354510
url https://repositorio.ufsc.br/handle/123456789/191072
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 289 p.| il., gráfs., tabs.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1808652181065170944