Estudo termo-estrutural de poços equipados com tubos isolados a vácuo

Detalhes bibliográficos
Autor(a) principal: Ferreira, Marcus Vinicius Duarte
Data de Publicação: 2017
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/handle/123456789/190146
Resumo: Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2017.
id UFSC_5f5a2b7b2efb8a2f2f5e67bfd6ddc68f
oai_identifier_str oai:repositorio.ufsc.br:123456789/190146
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Estudo termo-estrutural de poços equipados com tubos isolados a vácuoEngenharia mecânicaPoços de petroleoTese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2017.A exploração e produção de reservatórios de elevada pressão e temperatura e com grande potencial de produção de hidrocarbonetos, em cenários de águas profundas, impõe diversos desafios no que tange a integridade estrutural de poços de petróleo. Um problema recorrente é causado pelo fenômeno conhecido como APB (Annular Pressure Builup), consequência do processo de aquecimento do poço durante a produção de hidrocarbonetos oriundos do reservatório. Este aquecimento afeta o espaço anular do poço, que se encontra completamente selado e preenchido com fluido de perfuração, que sofre expansão térmica. A expansão do fluido aumenta a pressão anular para níveis que podem ultrapassar a resistência mecânica dos elementos tubulares que compõem o poço, levando à perda de sua integridade. A fim de evitar o colapso do tubo, várias estratégias são utilizadas para mitigar o APB, tal como o Vacuum Insulated Tubing (VIT). A técnica consiste na utilização de dois tubos de produção concêntricos que são soldados nas suas extremidades, formando um espaço anular, que então é evacuado, reduzindo a transferência de calor radial. No entanto, uma vez que a conexão entre cada dois tubos não é termicamente isolada, a transferência de calor pode ser significativa nesta região. O presente trabalho propõe um estudo teórico da transferência de calor no sistema VIT. Primeiramente, o problema térmico foi modelado e simulado com o auxílio de um software comercial utilizando o método dos volumes finitos (MVF). Foi proposto um modelo em regime permanente baseado em circuito térmico equivalente bidimensional (modelo nodal). Um refino do modelo nodal foi efetuado para que apresentasse resultados similares aos encontrados utilizando o MVF, sendo uma alternativa fácil para incorporação em um simulador multifísico de produção de petróleo em poços. Desta forma, o modelo térmico nodal do VIT foi acoplado a um simulador de produção de poços (hidrodinâmico-térmico-estrutural) gerando resultados mais realistas do que os atualmente empregados na indústria de petróleo. Estes resultados foram validados com dados de campo para dois poços de petróleo e contra resultados oriundos de um software comercial extensivamente utilizado por engenheiros de petróleo em projeto de poços.Abstract : Annular Pressure Buildup (APB) is a recurring problem that affects high pressure and high temperature wells during oil exploration and production in deepwater scenarios. Wellbore heating is caused by the upward flow of heated hydrocarbons towards the wellhead. The temperature rise affects the annular space of the borehole, which is often sealed and completely filled with drilling fluid, causing its expansion. The expansion of the fluid increases the annulus pressure to levels that can surpass the structural limits of the materials, posing a risk to the wellbore integrity. In order to avoid the collapse of the tube, several strategies are commonly used to mitigate APB, such as the use of Vacuum Insulated Tubing (VIT). This technique consists of using two concentric metallic tubes that are welded at their extremities, forming an annular space that is subsequently evacuated to minimize radial heat transfer. However, since the connection between each pair of tubes is not insulated, heat transfer can be significant in VIT junction region. This work proposes a theoretical analysis of the heat transfer in wells assisted by VIT systems. Firstly, the thermal problem was modeled and simulated using the finite volume method (FVM) with a commercial software package. A steady-state equivalent thermal network (ETN) model was developed and its mesh refinement was adjusted such that it provides results similar to those obtained with the FVM, but with a much lower computational cost. The VIT ETN model was then coupled to a multiphysics wellbore simulator (hydrodynamic-thermal-structural), producing potentially more realistic results for the oil industry. Such results have been compared and validated with field data from two actual petroleum wells and against data from a commercial software package extensively used by the major oil companies in wellbore design.Barbosa Junior, Jader RisoSilva, Alexandre Kupka daUniversidade Federal de Santa CatarinaFerreira, Marcus Vinicius Duarte2018-09-22T04:03:43Z2018-09-22T04:03:43Z2017info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis253 p.| il., gráfs., tabs.application/pdf354683https://repositorio.ufsc.br/handle/123456789/190146porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2018-09-22T04:03:45Zoai:repositorio.ufsc.br:123456789/190146Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732018-09-22T04:03:45Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Estudo termo-estrutural de poços equipados com tubos isolados a vácuo
title Estudo termo-estrutural de poços equipados com tubos isolados a vácuo
spellingShingle Estudo termo-estrutural de poços equipados com tubos isolados a vácuo
Ferreira, Marcus Vinicius Duarte
Engenharia mecânica
Poços de petroleo
title_short Estudo termo-estrutural de poços equipados com tubos isolados a vácuo
title_full Estudo termo-estrutural de poços equipados com tubos isolados a vácuo
title_fullStr Estudo termo-estrutural de poços equipados com tubos isolados a vácuo
title_full_unstemmed Estudo termo-estrutural de poços equipados com tubos isolados a vácuo
title_sort Estudo termo-estrutural de poços equipados com tubos isolados a vácuo
author Ferreira, Marcus Vinicius Duarte
author_facet Ferreira, Marcus Vinicius Duarte
author_role author
dc.contributor.none.fl_str_mv Barbosa Junior, Jader Riso
Silva, Alexandre Kupka da
Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Ferreira, Marcus Vinicius Duarte
dc.subject.por.fl_str_mv Engenharia mecânica
Poços de petroleo
topic Engenharia mecânica
Poços de petroleo
description Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2017.
publishDate 2017
dc.date.none.fl_str_mv 2017
2018-09-22T04:03:43Z
2018-09-22T04:03:43Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv 354683
https://repositorio.ufsc.br/handle/123456789/190146
identifier_str_mv 354683
url https://repositorio.ufsc.br/handle/123456789/190146
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 253 p.| il., gráfs., tabs.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1808652394993549312