Estudo do controle preditivo da termoacumulação de água gelada por meio de previsões de carga

Detalhes bibliográficos
Autor(a) principal: Krelling, Amanda Fraga
Data de Publicação: 2019
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/handle/123456789/215775
Resumo: Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2019.
id UFSC_5f70a07701c9ecf87df9334c8856a690
oai_identifier_str oai:repositorio.ufsc.br:123456789/215775
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Estudo do controle preditivo da termoacumulação de água gelada por meio de previsões de cargaEngenharia civilControle preditivoAr condicionadoÁguaEnergia térmicaDissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2019.O armazenamento de energia térmica em edificações proporciona a flexibilização de demandas, permitindo o deslocamento total ou parcial do consumo para períodos mais propícios, sob o ponto de vista técnico e econômico. O desempenho otimizado desses sistemas requer a sua coordenação com eventos externos à edificação, como as tarifas energéticas e as condições climáticas. O presente estudo procurou analisar a operação de um termoacumulador de água gelada com carregamento realizado de forma proporcional às cargas térmicas futuras de resfriamento de uma edificação comercial. A variação da carga armazenada foi realizada por meio do ajuste diário da temperatura da água no tanque. Modelos de sistemas de climatização foram comparados aos modelos com termoacumulação e aos modelos preditivos, considerando sua aplicação às cidades brasileiras do Rio de Janeiro, Porto Alegre e Recife, todas simuladas por meio do software EnergyPlus. Em comparação com um sistema sem armazenamento de energia, o uso da termoacumulação provocou a redução de até 15% do custo anual de energia elétrica. O modelo preditivo, no entanto, teve o desempenho mascarado devido à baixa participação do processo de carregamento do tanque na proporção de usos finais de energia elétrica da edificação. Considerando a energia elétrica total, a redução anual do consumo foi de 0,80%, enquanto o custo foi reduzido em 0,54% na cidade do Rio de Janeiro, que apresentou as características climáticas que levaram ao melhor desempenho do sistema, dentre as cidades analisadas. Por outro lado, quando observado o consumo do chiller que realiza o abastecimento da termoacumulação, o consumo anual de energia elétrica deste equipamento foi reduzido em até 10,2% com o modelo de previsões diárias. Além disso, o modelo proposto também permitiu a redução entre 12,5% e 36,4% do calor infiltrado no meio de armazenamento. Quando inseridas perturbações sobre as previsões de cargas, o sistema mostrou-se resiliente mesmo se subestimada a demanda diária em até 20%. A partir do desenvolvimento deste estudo, foi concluído que o desempenho de um sistema de termoacumulação com previsões de carga está intrinsecamente relacionado com a forma de aplicação dessas previsões. As características climáticas igualmente representam um parâmetro que influencia na viabilidade do modelo, podendo indicar a relevância da adoção de previsões de carga, assim como relacionando-se com a performance das máquinas do sistema de climatização.Abstract: Thermal energy storage (TES) in buildings provides flexibility to its demands, allowing partial or total load shifting to periods that are more favorable from a technical and economic point of view. The optimal performance of these systems requires their coordination with external events, such as energy tariffs and weather conditions. This study aimed to analyze the operation of a chilled water storage tank charged according to cooling loads forecasts of a commercial building. Variations in stored load were applied through daily adjustments of water temperature in the tank. Models of cooling systems were compared to TES models and to the predictive TES models, considering its application to the Brazilian cities of Rio de Janeiro, Porto Alegre and Recife, all simulated through the EnergyPlus software. Compared to a system without energy storage, the use of TES reduced the annual cost of electricity by up to 15%. The predictive model, however, had its performance masked due to the low participation of the tank charging process in the building's final energy uses. Considering the total electricity, the annual reduction in consumption was 0.80%, while the cost was reduced by 0.54% in the city of Rio de Janeiro, which presented the climatic characteristics that led to the best performance of the system, among the cities analyzed. On the other hand, when observed the consumption of the chiller that supplies the storage, its annual energy consumption was reduced by up to 10.2% with the daily forecast model. In addition, the proposed model also allowed a reduction between 12.5% and 36.4% of the heat gain to the storage medium. When disturbances to load forecasts were introduced, the system proved resilient even if it underestimated daily demand by up to 20%. From the development of this study, it was concluded that the performance of a load forecasting thermal energy storage is intrinsically related to how these forecasts are applied. Climatic characteristics also represent a parameter that will influence the model's viability, and may indicate the relevance of adopting load forecasts, as well as relating to the performance of the air conditioning machines.Guths, SauloWestphal, Fernando SimonUniversidade Federal de Santa CatarinaKrelling, Amanda Fraga2020-10-21T21:20:24Z2020-10-21T21:20:24Z2019info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis122 p.| il., gráfs.application/pdf369104https://repositorio.ufsc.br/handle/123456789/215775porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2020-10-21T21:20:24Zoai:repositorio.ufsc.br:123456789/215775Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732020-10-21T21:20:24Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Estudo do controle preditivo da termoacumulação de água gelada por meio de previsões de carga
title Estudo do controle preditivo da termoacumulação de água gelada por meio de previsões de carga
spellingShingle Estudo do controle preditivo da termoacumulação de água gelada por meio de previsões de carga
Krelling, Amanda Fraga
Engenharia civil
Controle preditivo
Ar condicionado
Água
Energia térmica
title_short Estudo do controle preditivo da termoacumulação de água gelada por meio de previsões de carga
title_full Estudo do controle preditivo da termoacumulação de água gelada por meio de previsões de carga
title_fullStr Estudo do controle preditivo da termoacumulação de água gelada por meio de previsões de carga
title_full_unstemmed Estudo do controle preditivo da termoacumulação de água gelada por meio de previsões de carga
title_sort Estudo do controle preditivo da termoacumulação de água gelada por meio de previsões de carga
author Krelling, Amanda Fraga
author_facet Krelling, Amanda Fraga
author_role author
dc.contributor.none.fl_str_mv Guths, Saulo
Westphal, Fernando Simon
Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Krelling, Amanda Fraga
dc.subject.por.fl_str_mv Engenharia civil
Controle preditivo
Ar condicionado
Água
Energia térmica
topic Engenharia civil
Controle preditivo
Ar condicionado
Água
Energia térmica
description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2019.
publishDate 2019
dc.date.none.fl_str_mv 2019
2020-10-21T21:20:24Z
2020-10-21T21:20:24Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv 369104
https://repositorio.ufsc.br/handle/123456789/215775
identifier_str_mv 369104
url https://repositorio.ufsc.br/handle/123456789/215775
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 122 p.| il., gráfs.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1808652139192385536