Avaliação experimental do desempenho térmico de trocadores de calor tubo capilar-linha de sucção

Detalhes bibliográficos
Autor(a) principal: Tabares Gómez, Diego Alejandro
Data de Publicação: 2018
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/handle/123456789/205197
Resumo: Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2018.
id UFSC_7603a031ed4329857e8fad830a27cc6f
oai_identifier_str oai:repositorio.ufsc.br:123456789/205197
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Universidade Federal de Santa CatarinaTabares Gómez, Diego AlejandroMelo, Claudio2020-03-31T13:30:52Z2020-03-31T13:30:52Z2018360595https://repositorio.ufsc.br/handle/123456789/205197Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2018.O presente trabalho está focado na área de refrigeração doméstica, especificamente no trocador de calor interno conformado pelo tubo capilar e a linha de sucção presentes no ciclo de operação. Visando analisar experimentalmente o desempenho térmico do trocador, conhecido como TC-TCLS, devido as vantagens que fornece ao sistema, o fluido refrigerante ambientalmente amigável com que opera, e a alta quantidade de configurações encontradas e pouca informação existente quando comparadas umas com outras. Nesses trocadores o tubo capilar pode ser fixado sobre a linha de sucção (lateral) ou inserido dentro dessa linha (concêntrico), dando origem a um tocador de calor do tipo contracorrente. Várias são as opções de projeto desse componente, com efeito sobre a efetividade e consequentemente sobre o desempenho térmico do sistema. Nesse contexto, torna-se necessário um estudo experimental sistemático entre as diversas configurações existentes, com o objetivo de encontrar uma correlação entre elas, foco maior desse trabalho. Para tanto, um aparato experimental foi projetado e construído, contemplando condições típicas de operação da refrigeração doméstica que opera com HC-600a como fluido refrigerante. Além do material e dos diâmetros do tubo capilar e da linha de sucção, foi variado também o tipo de acoplamento térmico utilizado nos trocadores de calor laterais. Os experimentos foram planejados em base estatística, com a temperatura de condensação variando entre 50°C e 35ºC, a de evaporação entre -10°C e -25ºC e o sub-resfriamento, na entrada do tubo capilar, entre 5°C e 10ºC. O grau de superaquecimento na entrada da linha de sucção, foi mantido constante em 10ºC. Observou-se que a bancada reproduz razoavelmente bem os dados reportados na literatura, com os desvios observados encontrando-se dentro da faixa de incerteza das medições realizadas. Além disso, observou-se que o material, tanto do tubo como do tubo capilar, não afeta significativamente a taxa de transferência de calor promovida pelo trocador de calor interno. Para uma mesma geometria o trocador lateral brasado apresentou uma taxa de transferência de calor 11% superior ao trocador de calor do tipo concêntrico e 24% superior ao lateral com fitas adesivas de alumínio.Abstract : The present work is focused on the domestic refrigeration area, specifically the internal heat exchanger conformed by the capillary tube and the suction line present in the operating cycle. Aiming to analyze experimentally the thermal performance of the exchanger, known as CTSL-HX, due to the advantages it provides to the system, the environmentally friendly refrigerant with which it operates, and the high amounts of configurations found and little existing information compared to each other. In these heat exchangers, the capillary tube can be fixed on the suction line (lateral) or inserted inside it (concentric), giving rise to a counter flow heat exchanger. There are several design options of this component, with effect on the effectiveness and consequently on the system s thermal performance. In this context, a systematic experimental study among the several existing configurations is necessary, in order to find a correlation between them, which is the major focus of this work. To do so, an experimental apparatus was designed and built, including typical conditions of operation of the household refrigeration area and HC-600a refrigerant. Besides the material and the diameters of the capillary tube and the suction line, the type of fixation used in the lateral heat exchangers was also varied. The experiments were planned on a statistical basis, with the condensation temperature varying between 50°C and 35°C, evaporation temperature between -10°C and -25°C and subcooling degree at the capillary tube inlet between 5°C and 10°C. The superheating degree at the inlet of the suction line was kept constant at 10°C. It was observed that the bench reproduces reasonably well the data reported in the literature, with the observed deviations being within the range of uncertainty of the measurements. In addition, it has been observed that the material of both the suction line and the capillary tube does not significantly affect the heat transfer rate promoted by the internal heat exchanger. As expected, the brazed lateral type heat exchanger proved to be the most effective of all tested configurations. For the same geometry, the brazed lateral type heat exchanger presents a heat transfer rate 11% higher than the concentric type heat exchanger and 24% higher than the lateral type with aluminum adhesive strips.137 p.| il., gráfs., tabs.porEngenharia mecânicaRefrigeradoresPermutadores térmicosAvaliação experimental do desempenho térmico de trocadores de calor tubo capilar-linha de sucçãoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccessORIGINALPEMC1933-D.pdfPEMC1933-D.pdfapplication/pdf2813540https://repositorio.ufsc.br/bitstream/123456789/205197/-1/PEMC1933-D.pdf72a5b3632856dba128d1de8ea8a3263cMD5-1123456789/2051972020-03-31 10:30:52.622oai:repositorio.ufsc.br:123456789/205197Repositório de PublicaçõesPUBhttp://150.162.242.35/oai/requestopendoar:23732020-03-31T13:30:52Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Avaliação experimental do desempenho térmico de trocadores de calor tubo capilar-linha de sucção
title Avaliação experimental do desempenho térmico de trocadores de calor tubo capilar-linha de sucção
spellingShingle Avaliação experimental do desempenho térmico de trocadores de calor tubo capilar-linha de sucção
Tabares Gómez, Diego Alejandro
Engenharia mecânica
Refrigeradores
Permutadores térmicos
title_short Avaliação experimental do desempenho térmico de trocadores de calor tubo capilar-linha de sucção
title_full Avaliação experimental do desempenho térmico de trocadores de calor tubo capilar-linha de sucção
title_fullStr Avaliação experimental do desempenho térmico de trocadores de calor tubo capilar-linha de sucção
title_full_unstemmed Avaliação experimental do desempenho térmico de trocadores de calor tubo capilar-linha de sucção
title_sort Avaliação experimental do desempenho térmico de trocadores de calor tubo capilar-linha de sucção
author Tabares Gómez, Diego Alejandro
author_facet Tabares Gómez, Diego Alejandro
author_role author
dc.contributor.none.fl_str_mv Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Tabares Gómez, Diego Alejandro
dc.contributor.advisor1.fl_str_mv Melo, Claudio
contributor_str_mv Melo, Claudio
dc.subject.classification.none.fl_str_mv Engenharia mecânica
Refrigeradores
Permutadores térmicos
topic Engenharia mecânica
Refrigeradores
Permutadores térmicos
description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2018.
publishDate 2018
dc.date.issued.fl_str_mv 2018
dc.date.accessioned.fl_str_mv 2020-03-31T13:30:52Z
dc.date.available.fl_str_mv 2020-03-31T13:30:52Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://repositorio.ufsc.br/handle/123456789/205197
dc.identifier.other.none.fl_str_mv 360595
identifier_str_mv 360595
url https://repositorio.ufsc.br/handle/123456789/205197
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 137 p.| il., gráfs., tabs.
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
bitstream.url.fl_str_mv https://repositorio.ufsc.br/bitstream/123456789/205197/-1/PEMC1933-D.pdf
bitstream.checksum.fl_str_mv 72a5b3632856dba128d1de8ea8a3263c
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1766805166405713920