Erro de medida de testes funcionais em idosos

Detalhes bibliográficos
Autor(a) principal: Silva, Mariane Eichendorf da
Data de Publicação: 2016
Tipo de documento: Trabalho de conclusão de curso
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/xmlui/handle/123456789/171605
Resumo: TCC (Graduação) - Universidade Federal de Santa Catarina. Centro de Desportos. Educação Física. Bacharelado.
id UFSC_8124cfd8b1db3b38b73512f607bac1f9
oai_identifier_str oai:repositorio.ufsc.br:123456789/171605
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Erro de medida de testes funcionais em idososConfiabilidade dos dadosValidade dos testesReprodutibilidade dos testesIdososExercício FísicoTCC (Graduação) - Universidade Federal de Santa Catarina. Centro de Desportos. Educação Física. Bacharelado.Os testes de Capacidade Funcional são utilizados para a avaliação e monitoramento de idosos em estudos científicos e na prática clínica. Com o objetivo de melhorar o controle de qualidade dessas medidas, aumentando a robustez metodológica, podem-se empregar cálculos que mensuram o erro de medida, como o Erro Técnico de Medida (ETM) e o coeficiente de credibilidade para avaliar a confiabilidade dos dados. O objetivo deste estudo foi avaliar a variabilidade inter-avaliadores e intra-avaliador em testes funcionais em idosos fisicamente ativos. Cinco avaliadores treinados avaliaram a capacidade funcional de 20 idosos por meio de seis testes funcionais: 1. Sentar e Levantar cinco vezes da cadeira; 2. Levanta, Vai e Volta; 3. Subir escadas; 4. Descer escadas; 5. Levantar e transportar; e 6. Velocidade de caminhada de 6 metros. O tempo de cada teste foi mensurado in situ, com o uso de cronômetros, além de ser registrado com câmera filmadora, de maneira simultânea. Um quinto avaliador mensurou o tempo do teste posteriormente por meio de software especializado, sendo que tais medidas foram consideradas como padrão ouro. Os principais resultados apontam que houve diferença significativa na maior parte dos resultados, apenas quatro médias, em três testes diferentes, não apresentaram diferença significativa em relação ao padrão ouro (p>0,05), foram estas no teste Levanta Vai e Volta do avaliador 2 (5,37±0,95s), Sentar e Levantar 5 vezes dos avaliadores 1 (10,12±1,57s) e 4 (10,12±1,5s) e Carregar e Transportar do avaliador 1 (8,07±1,18s); Observou-se ainda, que o erro ocorreu de maneira sistemática, ou seja, padrão e menor em relação as médias da câmera. Foram encontrados variados erros de medição inter e intra-avaliadores nos testes de capacidade funcional. Verificou-se que, quanto menor o tempo de realização do teste, maior é o valor do ETM encontrado, resultado confirmado no teste de correlação de Pearson que apontou correlação negativa entre a média de duração dos testes e a média do ETM inter (r=-0,868) e intra-avaliadores (r= -0,843) dos quatro avaliadores em cada teste realizado. Portanto, mostra-se necessário o uso da câmera como parte da avaliação, fornecendo resultados mais fidedignos. Nos casos de impossibilidade de uso, é importante realizar os cálculos de ETM inter e intra-avaliadores com o objetivo de garantir a confiabilidade dos dados.Functional Capacity tests are used for the evaluation and monitoring of the elderly in scientific studies and clinical practice. In order to improve the quality control of these measures, increasing the methodological robustness, we can use calculations that measure the measurement error, such as the Technical Error of Measure (ETM) and the coefficient of credibility to evaluate the reliability of the data. The objective of this study was to evaluate inter-rater and intra-rater variability in functional tests in physically active elderly. Five trained evaluators assessed the functional capacity of 20 elderly people through six functional tests: 1. Timed up and go (TUG), 2. Upstairs (US), 3. Downstairs (DS), 4. Sit 5 times (S5x), 5. Walking 8m (W8) and 6. Lift and carry (LC). The time of each test was measured in situ with stopwatches, besides being recorded with a camcorder, simultaneously. A fifth evaluator measured the test time later using specialized software, and these measurements were considered as gold standard. The main results indicate that there was a significant difference in most of the results, only four means, in three different tests, did not present significant difference in relation to the gold standard (p> 0.05). These were in the Time Up and Go test of the evaluator 2 (5.37 ± 0.95 s), Sit and Raise 5 times of the evaluators 1 (10.12 ± 1.57 s) and 4 (10.12 ± 1.5 s) and Load and Transport of evaluator 1 (8.07 ± 1.18 s). It was also observed that the error occurred in a systematic way, that is, smaller in relation to the camera means. Several inter- and intra-rater measurement errors were found in the functional capacity tests. It was found that the shorter the test time, the higher the ETM value was found, confirmed in the Pearson correlation test, which showed a negative correlation between the mean duration of the tests and the mean ETM inter (r = -0.868) and intra-rater (r = -0.843) of the four raters in each test performed. Therefore, it is necessary to use the camera as part of the evaluation, providing a more reliable result. In cases where it is impossible to use camera, it is important to perform inter-and intra-rater ETM calculations in order to guarantee the reliability of the data.Florianópolis, SCFreitas, Cíntia de la RochaOrssatto, Lucas Bet da RosaUniversidade Federal de Santa Catarina.Silva, Mariane Eichendorf da2016-12-16T02:28:16Z2016-12-16T02:28:16Z2016-12-16info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis54f.application/pdfhttps://repositorio.ufsc.br/xmlui/handle/123456789/171605porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2016-12-16T02:28:16Zoai:repositorio.ufsc.br:123456789/171605Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732016-12-16T02:28:16Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Erro de medida de testes funcionais em idosos
title Erro de medida de testes funcionais em idosos
spellingShingle Erro de medida de testes funcionais em idosos
Silva, Mariane Eichendorf da
Confiabilidade dos dados
Validade dos testes
Reprodutibilidade dos testes
Idosos
Exercício Físico
title_short Erro de medida de testes funcionais em idosos
title_full Erro de medida de testes funcionais em idosos
title_fullStr Erro de medida de testes funcionais em idosos
title_full_unstemmed Erro de medida de testes funcionais em idosos
title_sort Erro de medida de testes funcionais em idosos
author Silva, Mariane Eichendorf da
author_facet Silva, Mariane Eichendorf da
author_role author
dc.contributor.none.fl_str_mv Freitas, Cíntia de la Rocha
Orssatto, Lucas Bet da Rosa
Universidade Federal de Santa Catarina.
dc.contributor.author.fl_str_mv Silva, Mariane Eichendorf da
dc.subject.por.fl_str_mv Confiabilidade dos dados
Validade dos testes
Reprodutibilidade dos testes
Idosos
Exercício Físico
topic Confiabilidade dos dados
Validade dos testes
Reprodutibilidade dos testes
Idosos
Exercício Físico
description TCC (Graduação) - Universidade Federal de Santa Catarina. Centro de Desportos. Educação Física. Bacharelado.
publishDate 2016
dc.date.none.fl_str_mv 2016-12-16T02:28:16Z
2016-12-16T02:28:16Z
2016-12-16
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://repositorio.ufsc.br/xmlui/handle/123456789/171605
url https://repositorio.ufsc.br/xmlui/handle/123456789/171605
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 54f.
application/pdf
dc.publisher.none.fl_str_mv Florianópolis, SC
publisher.none.fl_str_mv Florianópolis, SC
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1808652112409657344