Analysis of total harmonic distortion performance in grid-tied single-phase voltage source inverters through closed-loop modeling

Detalhes bibliográficos
Autor(a) principal: Gruner, Víctor Ferreira
Data de Publicação: 2023
Tipo de documento: Tese
Idioma: eng
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/handle/123456789/254884
Resumo: Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2023.
id UFSC_85b2d429cd70227f7075910d2a3f7553
oai_identifier_str oai:repositorio.ufsc.br:123456789/254884
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Analysis of total harmonic distortion performance in grid-tied single-phase voltage source inverters through closed-loop modelingEngenharia elétricaDistorção eletricaInversores elétricosEnergia elétricaTese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2023.Esta tese apresenta uma metodologia para estimar, na etapa de projeto, a distorção harmônica total da corrente injetada na rede elétrica por inversores fonte de tensão de dois estágios. Como tais inversores operam em malha fechada, a qualidade da correte injetada na rede elétrica é altamente dependente da dinâmica das malhas de controle. Assim, é necessário focar em uma abordagem que modele o comportamento da corrente injetada na rede considerando as perturbações em malha fechada. A abordagem proposta possibilita a derivação de uma equação para prever o comportamento da corrente injetada na rede e estimar sua distorção harmônica, tornando-se uma importante ferramenta para otimizar o projeto de inversores conectados à rede. Para validar a acurácia da metodologia desenvolvida, são apresentados resultados experimentais em diferentes cenários de operação.Abstract: This thesis presents a methodology to estimate, in the design stage, the total harmonic distortion of the current injected into the power grid by two-stage voltage source inverters (VSI). As such inverters operate in a closed loop, the quality of the grid current is highly dependent on the dynamics of the control loops. Thus, it is necessary to focus on an approach to model the behavior of the grid current considering the closed-loop disturbances. The proposed approach allows the derivation of an equation to predict the behavior of the current injected into the grid and estimate its harmonic distortion, becoming an important tool for optimal design of grid-connected inverters. To validate the accuracy of the developed methodology, experimental results are presented in different operating scenarios.Coelho, Roberto FranciscoMartins, Denizar CruzUniversidade Federal de Santa CatarinaGruner, Víctor Ferreira2024-04-01T23:24:22Z2024-04-01T23:24:22Z2023info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis139 p.| il., gráfs.application/pdf386716https://repositorio.ufsc.br/handle/123456789/254884engreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2024-04-01T23:24:22Zoai:repositorio.ufsc.br:123456789/254884Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732024-04-01T23:24:22Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Analysis of total harmonic distortion performance in grid-tied single-phase voltage source inverters through closed-loop modeling
title Analysis of total harmonic distortion performance in grid-tied single-phase voltage source inverters through closed-loop modeling
spellingShingle Analysis of total harmonic distortion performance in grid-tied single-phase voltage source inverters through closed-loop modeling
Gruner, Víctor Ferreira
Engenharia elétrica
Distorção eletrica
Inversores elétricos
Energia elétrica
title_short Analysis of total harmonic distortion performance in grid-tied single-phase voltage source inverters through closed-loop modeling
title_full Analysis of total harmonic distortion performance in grid-tied single-phase voltage source inverters through closed-loop modeling
title_fullStr Analysis of total harmonic distortion performance in grid-tied single-phase voltage source inverters through closed-loop modeling
title_full_unstemmed Analysis of total harmonic distortion performance in grid-tied single-phase voltage source inverters through closed-loop modeling
title_sort Analysis of total harmonic distortion performance in grid-tied single-phase voltage source inverters through closed-loop modeling
author Gruner, Víctor Ferreira
author_facet Gruner, Víctor Ferreira
author_role author
dc.contributor.none.fl_str_mv Coelho, Roberto Francisco
Martins, Denizar Cruz
Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Gruner, Víctor Ferreira
dc.subject.por.fl_str_mv Engenharia elétrica
Distorção eletrica
Inversores elétricos
Energia elétrica
topic Engenharia elétrica
Distorção eletrica
Inversores elétricos
Energia elétrica
description Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2023.
publishDate 2023
dc.date.none.fl_str_mv 2023
2024-04-01T23:24:22Z
2024-04-01T23:24:22Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv 386716
https://repositorio.ufsc.br/handle/123456789/254884
identifier_str_mv 386716
url https://repositorio.ufsc.br/handle/123456789/254884
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 139 p.| il., gráfs.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1808652005671960576