Performance assessment of solar photovoltaic technologies under different climatic conditions in Brazil

Detalhes bibliográficos
Autor(a) principal: Nascimento, Lucas Rafael do
Data de Publicação: 2019
Tipo de documento: Tese
Idioma: eng
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/handle/123456789/204420
Resumo: Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2019.
id UFSC_9d3060c8c3b3120a8c6ceee8abe42923
oai_identifier_str oai:repositorio.ufsc.br:123456789/204420
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Universidade Federal de Santa CatarinaNascimento, Lucas Rafael doRüther, Ricardo2020-02-28T18:04:14Z2020-02-28T18:04:14Z2019364837https://repositorio.ufsc.br/handle/123456789/204420Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2019.A geração fotovoltaica (FV) centralizada tem apresentado um importante crescimento no Brasil nos últimos anos, consequência de intensa redução de seus custos de produção. As elevadas temperaturas de operação, os altos níveis de umidade e irradiância e uma distribuição de irradiância em um espectro desviado para o azul em comparação com o espectro padrão ASTM G-173, levam a resultados operacionais contrastantes das várias tecnologias FV comercialmente disponíveis, que são evidenciados nesta tese. Este trabalho avalia oito Módulos de Avaliação (MAs) idênticos instalados em oito regiões climáticas do Brasil, cada um possuindo uma potência instalada de 54 kWp e utilizando as seguintes tecnologias fotovoltaicas: Silício amorfo (a-Si), Silício microcristalino (µc-Si), Telureto de Cádmio (CdTe), Disseleneto de Cobre-Índio-Gálio (CIGS), Silício mono e multi-cristalino (c-Si e m-Si). Todas os sistemas operam com inclinação idêntica à latitude local correspondente. Parâmetros elétricos e ambientais em todos os locais são medidos continuamente em intervalos de um segundo. Os resultados mostram uma análise detalhada das perdas de energia para todas as tecnologias. Os módulos fotovoltaicos de filmes finos com baixo coeficiente de temperatura apresentaram elevada taxa de desempenho. Módulos de silício cristalino revelaram intensa degradação em áreas com alta umidade relativa e temperatura. Apesar das diferentes tecnologias FV avaliadas, os resultados encontrados estão diretamente associados aos fabricantes dos módulos utilizados e não necessariamente refletem o comportamento destas tecnologias como um todo. Os efeitos de sobreirradiância causados por eventos de borda de nuvem resultaram em picos de irradiância de até 1845 W/m², com eventos que duraram vários minutos acima de 1600 W/m², resultando em frequentes queimas de fusíveis, mesmo quando foram observadas as recomendações dos fabricantes dos módulos fotovoltaicos. A soma de todos os efeitos observados e descritos nesta tese demonstra que o dimensionamento e operação de usinas solares fotovoltaicas de grande porte nas distintas regiões do Brasil apresentam peculiaridades que até o presente pouco foram descritas na literatura científica especializada.Abstract: Utility-scale photovoltaic (PV) generation is being ramped-up in Brazil in recent years, as a result of intense price reductions. Extreme operating temperatures, high humidity, and irradiance levels, and a blue-biased distribution of irradiance in comparison with the standard ASTM G-173 spectrum lead to contrasting operational outputs of the various commerciallyavailable PV technologies. The performance assessment of six different PV technologies installed at eight different climatic regions in Brazil is presented. This thesis evaluates eight identical, 54 kWp Evaluation Sites (ESs), all with the following PV technologies: amorphoussilicon (a-Si), microcrystalline-silicon (a-Si/µc-Si), cadmium-telluride (CdTe), copper-indiumgallium- diselenide (CIGS), mono- and multi-crystalline silicon (c-Si and m-Si). All installations operate at a fixed-tilt equal to the corresponding local latitude. Electrical and environmental parameters at all sites are measured continuously at one-second intervals. A detailed energy loss analysis for all technologies is presented. Thin-film PV modules with a low temperature-coefficient of power presented superior performance. Crystalline silicon modules revealed severe degradation in areas with high relative humidity and temperature. Even though several PV technologies were assessed, the results presented are directly related to the specific manufacturers of the modules employed in the project, and not necessarily reflect the PV technologies behavior as a whole. Cloud-edge and cloud-enhancement effects of solar irradiance resulted in irradiance peaks of up to 1845 W/m², with long overirradiance events which lasted many minutes over 1600 W/m², resulting in the frequent blowing of string fuses when manufacturers maximum fuse ratings were employed. The combined effect of all the phenomena observed and described in this thesis demonstrates that the sizing and operating of utility-scale PV in the different climatic regions in Brazil presents peculiarities which have not been extensively described in the scientific literature so far.104 p.| il., gráfs., tabs.engEngenharia civilGeração de energia fotovoltaicaSistemas de energia fotovoltaicaPerformance assessment of solar photovoltaic technologies under different climatic conditions in Brazilinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccessORIGINALPECV1179-T.pdfPECV1179-T.pdfapplication/pdf9763774https://repositorio.ufsc.br/bitstream/123456789/204420/-1/PECV1179-T.pdf71a29dd123ad2554106d68bd0fd7e375MD5-1123456789/2044202020-02-28 15:04:14.668oai:repositorio.ufsc.br:123456789/204420Repositório de PublicaçõesPUBhttp://150.162.242.35/oai/requestopendoar:23732020-02-28T18:04:14Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Performance assessment of solar photovoltaic technologies under different climatic conditions in Brazil
title Performance assessment of solar photovoltaic technologies under different climatic conditions in Brazil
spellingShingle Performance assessment of solar photovoltaic technologies under different climatic conditions in Brazil
Nascimento, Lucas Rafael do
Engenharia civil
Geração de energia fotovoltaica
Sistemas de energia fotovoltaica
title_short Performance assessment of solar photovoltaic technologies under different climatic conditions in Brazil
title_full Performance assessment of solar photovoltaic technologies under different climatic conditions in Brazil
title_fullStr Performance assessment of solar photovoltaic technologies under different climatic conditions in Brazil
title_full_unstemmed Performance assessment of solar photovoltaic technologies under different climatic conditions in Brazil
title_sort Performance assessment of solar photovoltaic technologies under different climatic conditions in Brazil
author Nascimento, Lucas Rafael do
author_facet Nascimento, Lucas Rafael do
author_role author
dc.contributor.none.fl_str_mv Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Nascimento, Lucas Rafael do
dc.contributor.advisor1.fl_str_mv Rüther, Ricardo
contributor_str_mv Rüther, Ricardo
dc.subject.classification.none.fl_str_mv Engenharia civil
Geração de energia fotovoltaica
Sistemas de energia fotovoltaica
topic Engenharia civil
Geração de energia fotovoltaica
Sistemas de energia fotovoltaica
description Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2019.
publishDate 2019
dc.date.issued.fl_str_mv 2019
dc.date.accessioned.fl_str_mv 2020-02-28T18:04:14Z
dc.date.available.fl_str_mv 2020-02-28T18:04:14Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://repositorio.ufsc.br/handle/123456789/204420
dc.identifier.other.none.fl_str_mv 364837
identifier_str_mv 364837
url https://repositorio.ufsc.br/handle/123456789/204420
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 104 p.| il., gráfs., tabs.
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
bitstream.url.fl_str_mv https://repositorio.ufsc.br/bitstream/123456789/204420/-1/PECV1179-T.pdf
bitstream.checksum.fl_str_mv 71a29dd123ad2554106d68bd0fd7e375
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1766805032292843520