Teste máximo de 3 minutos em ciclo-ergômetro isocinético: análise de reprodutibilidade e respostas fisiológicas em duas cadências de pedalada

Detalhes bibliográficos
Autor(a) principal: Lucas, Ricardo Dantas de
Data de Publicação: 2012
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: http://repositorio.ufsc.br/xmlui/handle/123456789/101020
Resumo: Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Desportos, Programa de Pós-Graduação em Educação Física, Florianópolis, 2012
id UFSC_9d88cc9f6a6b91286cea69500f72825a
oai_identifier_str oai:repositorio.ufsc.br:123456789/101020
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Universidade Federal de Santa CatarinaLucas, Ricardo Dantas deDenadai, Benedito Sérgio2013-06-26T00:50:45Z2013-06-26T00:50:45Z20122012314357http://repositorio.ufsc.br/xmlui/handle/123456789/101020Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Desportos, Programa de Pós-Graduação em Educação Física, Florianópolis, 2012A partir da relação entre cargas de trabalho e os seus respectivos tempos de exaustão pode-se estabelecer parâmetros relacionados tanto à capacidade aeróbia (potência crítica), como à capacidade anaeróbia. Recentemente foi proposto na literatura, um teste máximo (all-out) com 3 minutos de duração (3MT) em ciclo-ergômetro, a fim de estabelecer os mesmos parâmetros obtidos pelo conceito "clássico" da potência crítica, e adicionalmente mensurar também o consumo máximo de O2 ( O2max). O objetivo deste estudo, foi analisar a reprodutibilidade dos parâmetros mecânicos e também do O2pico obtidos do 3MT em um ciclo-ergômetro isocinético, utilizando duas cadências de pedalada (60rpm e 100rpm). Um segundo objetivo foi comparar as respostas obtidas no 3MT entre as duas cadências analisadas. A validade do O2pico também foi analisada. Participaram deste estudo 14 indivíduos sadios e fisicamente ativos (27,1 ± 4,5 anos de idade; 174,8 ± 5,5 cm e 77,7 ± 9,6 kg) que realizaram os seguintes testes: um teste incremental de rampa e quatro 3MT em ciclismo isocinético (dois a 60rpm e dois a 100rpm, randomizados). A partir destes testes foram determinados os seguintes índices: potência pico (PP), potência média (MP), potência média dos últimos 30 s, ou potência final (EP), índice de fadiga (IF), trabalho realizado acima da EP (WEP), trabalho total (Wtotal) e o O2pico. Para análise de reprodutibilidade foram utilizados: a análise de variânciatwo-way (testes versus cadência) de medidas repetidas, teste post hoc de Bonferroni, o teste de correlação intraclasse (ICC), além do erro típico de medida (ETM). Para comparação entre as cadências, foram utilizados: a análise de variância one-way de medidas repetidas, o teste t de Student para amostras pareadas, e o coeficiente de correlação de Pearson. Foi adotado um nível de significância de 5%.Todos os índices analisados não apresentaram diferença significante entre o teste e o reteste para cada cadência. O O2pico obtido nos 3MT foi altamente reprodutível (ICC> 0,97 e ETM< 3,2%) e não apresentou diferença com o obtido no teste incremental (p<0,05). Dentre os parâmetros mecânicos, a MP juntamente com o Wtotal foram os índices que apresentaram melhor reprodutibilidade (ICC> 0,97 e ETM<3%) para ambas as cadências, seguidas da EP (ICC> 0,91 e ETM<6%), IF (ICC>0,80 e ETM<4%), PP (ICC>0,81 e ETM<10%), e WEP (ICC>0,79 e ETM<10,5%). Além disto foi encontrada diferença significante entre as cadências (p<0,05), para todos os índices mecânicos, com exceção da WEP. Conclui-se que o tanto o perfil de potência como o O2pico obtido no 3MT isocinético são altamente reprodutíveis, nas cadências de 60 e 100 rpm. Além disto, o O2picoé uma medida válida quando obtida no 3MT isocinético. Mais pesquisas são necessárias para determinar a validade e consequentemente o significado fisiológico, em especial da EP e do WEP, obtidos em diferentes cadências.<br>Abstract : From the relationship between work-rates and times to exhaustion it can be determine parameters related to both aerobic (i.e. crítical power) and anaerobic capacity. Recently, it was proposed in literature, an all-out cycling test, lasting 3 minutes (3MT), in order to determine the same parameters found by the classical concept of crítical power, and also measure the maximal O2 consumption ( O2max). The aim of this study was to analyze the reliability of mechanical parameters and O2max derived from a 3MT isokinetic cycling, during two cadences (60rpm e 100rpm). Further, it was analyzed the cadence effects on responses derived from 3MT isokinetic. The validity of the 3MT O2peak was also tested. Fourteen healthy and active male subjects (27.1 ± 4.5 years; 174.8 ± 5.5 cm and 77.7 ± 9.6 kg) completed an incremental ramp testing (GXT) and four randomized 3MT (two at 60-rpm and two at 100-rpm). The following parameters were analyzed: peak power (PP), mean power (MP), end power (EP), fatigue index (FI), work performed above EP (WEP), total work (Wtotal) and O2peak. Reliability analyses were conducted by: ANOVA two-way (trials vs. cadences) with repeated measure, post hoc test of Bonferroni, intra class coefficient of correlation (ICC), and typical error of measurement (TEM). To compare between-cadence effect it was used: ANOVA one-way with repeated measure, paired t-test and Pearson#s coefficient of correlation. No difference was found for all variables between test-retest. The O2peak derived from 3MTshowed high reliability (ICC> 0.97 and TEM< 3.2%) and did not show differences with GXT O2peak (p<0.05). Regarding mechanical parameters, the MP together with Wtotal were the most reliable indices (ICC> 0.97 and ETM<3%), following by EP (ICC> 0.91 and ETM<6%), IF (ICC>0.80 and ETM<4%), PP (ICC>0.81 and ETM<10%), and WEP (ICC>0.79 and ETM<10.5%). Furthermore it was found a significant difference between cadences, for all mechanical indices, excepting WEP. In conclusion, both power profile and O2peak are highly reliable, in cadences of 60-rpm and 100-rpm. Furthermore the O2peak is a valid measure when derived from isokinetic 3MT. More researches are necessary to determine the validity and therefore the physiological meaning, especially of EP and WEP, derived from different cadences.133 p.| grafs., tabs.porEducação físicaCiclismoAptidão fisicaCiclistasFadigaTeste máximo de 3 minutos em ciclo-ergômetro isocinético: análise de reprodutibilidade e respostas fisiológicas em duas cadências de pedaladainfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccessORIGINAL314357.pdfapplication/pdf862391https://repositorio.ufsc.br/bitstream/123456789/101020/1/314357.pdf605b5935f538d3be9463e1e647ce5b3eMD51123456789/1010202013-06-25 21:50:45.232oai:repositorio.ufsc.br:123456789/101020Repositório de PublicaçõesPUBhttp://150.162.242.35/oai/requestopendoar:23732013-06-26T00:50:45Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.pt_BR.fl_str_mv Teste máximo de 3 minutos em ciclo-ergômetro isocinético: análise de reprodutibilidade e respostas fisiológicas em duas cadências de pedalada
title Teste máximo de 3 minutos em ciclo-ergômetro isocinético: análise de reprodutibilidade e respostas fisiológicas em duas cadências de pedalada
spellingShingle Teste máximo de 3 minutos em ciclo-ergômetro isocinético: análise de reprodutibilidade e respostas fisiológicas em duas cadências de pedalada
Lucas, Ricardo Dantas de
Educação física
Ciclismo
Aptidão fisica
Ciclistas
Fadiga
title_short Teste máximo de 3 minutos em ciclo-ergômetro isocinético: análise de reprodutibilidade e respostas fisiológicas em duas cadências de pedalada
title_full Teste máximo de 3 minutos em ciclo-ergômetro isocinético: análise de reprodutibilidade e respostas fisiológicas em duas cadências de pedalada
title_fullStr Teste máximo de 3 minutos em ciclo-ergômetro isocinético: análise de reprodutibilidade e respostas fisiológicas em duas cadências de pedalada
title_full_unstemmed Teste máximo de 3 minutos em ciclo-ergômetro isocinético: análise de reprodutibilidade e respostas fisiológicas em duas cadências de pedalada
title_sort Teste máximo de 3 minutos em ciclo-ergômetro isocinético: análise de reprodutibilidade e respostas fisiológicas em duas cadências de pedalada
author Lucas, Ricardo Dantas de
author_facet Lucas, Ricardo Dantas de
author_role author
dc.contributor.pt_BR.fl_str_mv Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Lucas, Ricardo Dantas de
dc.contributor.advisor1.fl_str_mv Denadai, Benedito Sérgio
contributor_str_mv Denadai, Benedito Sérgio
dc.subject.classification.pt_BR.fl_str_mv Educação física
Ciclismo
Aptidão fisica
Ciclistas
Fadiga
topic Educação física
Ciclismo
Aptidão fisica
Ciclistas
Fadiga
description Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Desportos, Programa de Pós-Graduação em Educação Física, Florianópolis, 2012
publishDate 2012
dc.date.submitted.pt_BR.fl_str_mv 2012
dc.date.issued.fl_str_mv 2012
dc.date.accessioned.fl_str_mv 2013-06-26T00:50:45Z
dc.date.available.fl_str_mv 2013-06-26T00:50:45Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufsc.br/xmlui/handle/123456789/101020
dc.identifier.other.pt_BR.fl_str_mv 314357
identifier_str_mv 314357
url http://repositorio.ufsc.br/xmlui/handle/123456789/101020
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 133 p.| grafs., tabs.
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
bitstream.url.fl_str_mv https://repositorio.ufsc.br/bitstream/123456789/101020/1/314357.pdf
bitstream.checksum.fl_str_mv 605b5935f538d3be9463e1e647ce5b3e
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1766805289598713856