Modelagem de dispersão e estimativa de risco associado às emissões industriais de MP10 no município de Joinville/SC

Detalhes bibliográficos
Autor(a) principal: Rodrigues, Jonatan
Data de Publicação: 2021
Tipo de documento: Artigo de conferência
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/handle/123456789/220211
Resumo: TCC(graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Sanitária e Ambiental.
id UFSC_b0b7fda0bc656fa55bff1ab3f0132729
oai_identifier_str oai:repositorio.ufsc.br:123456789/220211
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Modelagem de dispersão e estimativa de risco associado às emissões industriais de MP10 no município de Joinville/SCPoluição atmosféricaEmissões IndustriaisAERMODQualidade do ar em JoinvilleTCC(graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Sanitária e Ambiental.A poluição atmosférica é um grande problema global, que está vinculado a incidência de inúmeras doenças respiratórias e pode estar associado a industrialização em centros urbanos, sendo fundamental o desenvolvimento de metodologias de avaliação dos riscos à saúde da população. O objetivo do presente trabalho foi avaliar o impacto das emissões industriais de monóxido de carbono e material particulado na qualidade do ar do município de Joinville entre os anos de 2017 e 2019. Para tanto, o modelo computacional de dispersão de poluentes, AERMOD, foi utilizado. A abrangência e incidência de casos que excedem os padrões finais (PF) de qualidade do ar definidos na legislação CONAMA 491/2018 foram investigados. O método de Regressão de Poisson permitiu verificar o comportamento entre as variáveis independentes. A partir dessa relação foi calculado o Risco Relativo (RR) que uma pessoa tem de ser internada em função dos níveis de poluição. Foi considerada a base de dados do Sistema Nacional de Saúde (DataSUS), para as doenças do Capítulo X, Doenças do Aparelho Respiratório (J00-J99). Os resultados mostraram que o valor máximo das concentrações de MP10 para o tempo médio de 24h foi de 140μg/m³, superando o PF estabelecido pela legislação. Para o poluente CO não houve registro de violação do PF, e a máxima concentração estimada para o tempo de 8h foi de 257μg/m³. Aplicada a medida de controle, os eventos críticos diminuíram em 93%. O grupo de doenças que apresentou o maior risco foram as Doenças Respiratórias para todas as idades, que indica que a cada aumento de 10μg/m³ de MP10, as chances de alguém ser internado por uma doença respiratória aumentam em 17.6%. Referente ao grupo de Doenças Respiratórias para crianças menores do que 5 anos o RR foi de 11.7%. O maior RR foi encontrado para o Ponto 1, localizado no bairro Boa Vista. O estudo apontou, conforme esperado, que as piores localidades em relação a qualidade do ar estão próximas às fontes industriais e estimou o impacto na saúde da população correlacionado às concentrações estimadas. Levanta-se hipóteses que podem guiar futuras pesquisas acerca da temática e auxiliar na compreensão dos riscos ambientais a saúde humana no município de Joinville, reforçando o controle das emissões como importante ponto de atenção para as políticas públicas.Air pollution is seen as a global problem, which is linked to an effect of respiratory diseases and may be associated with industrialization in urban center, it is essential to develop methodologies for assessing the health risks of the population. The objective of this study was to evaluate the impact of industrial losses of CO and MP10, on the air quality of the city of Joinville between the years 2017 and 2019. For that, the computational model of dispersion of pollutants, AERMOD, was used. The scope and incidence of cases that exceed the final air quality standards (PF) defined in the CONAMA 491/2018 legislation were investigated. The Poisson regression method was used to verify the behavior between the independent variables. Based on this relationship, the Risk Relative (RR) that a person has to be hospitalized based on base levels was based. The database of the National Health System (DataSUS) was used for the diseases of Chapter X, Diseases of the Respiratory System (J00-J99). The limited results that the maximum value of the MP10 needs for the average time of 24h was 140μg/m³, exceeding the PF established by the legislation. For the pollutant CO there was no record of violation of the PF, and the maximum concentration estimated for the time of 8h was 257μg/m³. The measure of control of agreed events reduced by 93% was applied. The group of diseases that had the highest RR were Respiratory Diseases for all ages, with a calculated risk value of 17.6%, compared to Respiratory Diseases for children under 5 years of 11.7%. The largest RRs were found for Ponto 1, located in the Boa Vista neighborhood. The study pointed out, as expected, that the worst locations in relation to air quality are close to industrial sources and estimated the impact on the population's health correlated to the estimated concentrations. Hypotheses are raised that can guide future research on the subject and assist in the understanding of environmental risks to human health in the municipality of Joinville, reinforcing the control of emissions as an important point of attention for public policies.Florianópolis, SC.Hoinaski, LeonardoUniversidade Federal de Santa CatarinaRodrigues, Jonatan2021-02-18T18:41:15Z2021-02-18T18:41:15Z2021-02-12info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject90fapplication/pdfhttps://repositorio.ufsc.br/handle/123456789/220211info:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSC2021-02-18T18:41:15Zoai:repositorio.ufsc.br:123456789/220211Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732021-02-18T18:41:15Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Modelagem de dispersão e estimativa de risco associado às emissões industriais de MP10 no município de Joinville/SC
title Modelagem de dispersão e estimativa de risco associado às emissões industriais de MP10 no município de Joinville/SC
spellingShingle Modelagem de dispersão e estimativa de risco associado às emissões industriais de MP10 no município de Joinville/SC
Rodrigues, Jonatan
Poluição atmosférica
Emissões Industriais
AERMOD
Qualidade do ar em Joinville
title_short Modelagem de dispersão e estimativa de risco associado às emissões industriais de MP10 no município de Joinville/SC
title_full Modelagem de dispersão e estimativa de risco associado às emissões industriais de MP10 no município de Joinville/SC
title_fullStr Modelagem de dispersão e estimativa de risco associado às emissões industriais de MP10 no município de Joinville/SC
title_full_unstemmed Modelagem de dispersão e estimativa de risco associado às emissões industriais de MP10 no município de Joinville/SC
title_sort Modelagem de dispersão e estimativa de risco associado às emissões industriais de MP10 no município de Joinville/SC
author Rodrigues, Jonatan
author_facet Rodrigues, Jonatan
author_role author
dc.contributor.none.fl_str_mv Hoinaski, Leonardo
Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Rodrigues, Jonatan
dc.subject.por.fl_str_mv Poluição atmosférica
Emissões Industriais
AERMOD
Qualidade do ar em Joinville
topic Poluição atmosférica
Emissões Industriais
AERMOD
Qualidade do ar em Joinville
description TCC(graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Sanitária e Ambiental.
publishDate 2021
dc.date.none.fl_str_mv 2021-02-18T18:41:15Z
2021-02-18T18:41:15Z
2021-02-12
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/conferenceObject
format conferenceObject
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://repositorio.ufsc.br/handle/123456789/220211
url https://repositorio.ufsc.br/handle/123456789/220211
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 90f
application/pdf
dc.publisher.none.fl_str_mv Florianópolis, SC.
publisher.none.fl_str_mv Florianópolis, SC.
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1808652041109635072