Fatores humanos associados aos projetos de design: protocolo de coleta para a captura de movimentos

Detalhes bibliográficos
Autor(a) principal: Varnier, Thiago
Data de Publicação: 2019
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/handle/123456789/215019
Resumo: Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Comunicação e Expressão, Programa de Pós-Graduação em Design, Florianópolis, 2019.
id UFSC_c2b4660733023e1246fde9126efabe41
oai_identifier_str oai:repositorio.ufsc.br:123456789/215019
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Universidade Federal de Santa CatarinaVarnier, ThiagoMerino, Giselle Schmidt Alves Díaz2020-10-21T21:12:18Z2020-10-21T21:12:18Z2019361491https://repositorio.ufsc.br/handle/123456789/215019Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Comunicação e Expressão, Programa de Pós-Graduação em Design, Florianópolis, 2019.O Design visa melhorar a qualidade de vida das pessoas por meio do desenvolvimento de projetos, os quais devem considerar as capacidades e limitações dos usuários. Logo, associar os Fatores Humanos neste processo permite alcançar a melhor integração entre o produto e seus usuários. No entanto, configura-se nesta pesquisa o seguinte questionamento: como levantar dados precisos e confiáveis com os usuários referentes a biomecânica e cinemática, para o desenvolvimento de projetos de Design? A este respeito, a captura de movimentos pode ser um recurso auxiliar na obtenção destes dados objetivos. Todavia requer o uso de procedimentos sistemáticos de modo a garantir que os dados sejam válidos. Neste contexto, o objetivo geral desta pesquisa foi desenvolver um protocolo de coleta (orientações e diretrizes) para o levantamento de dados objetivos com os usuários referente a biomecânica e cinemática provenientes da captura de movimentos por sensores inerciais (equipamento MVN Link Biomech da Xsens). A pesquisa foi dividida em quatro fases: Fundamentação Teórica; Experiências Práticas; Desenvolvimento do Protocolo e Apresentação do Protocolo. A metodologia utilizada consistiu em uma etapa exploratória, com revisão de literatura e experiências práticas, posteriormente descritiva e correlacional para o desenvolvimento do protocolo e uma etapa explicativa em que o protocolo foi aplicado e avaliado para seu aprimoramento. Seu desenvolvimento foi conduzido pelo levantamento teórico (sistematização de protocolos, técnicas e métodos) e prático (experiências em laboratório e coleta de dados com usuários reais) dos procedimentos de levantamentos de dados com usuários envolvendo o equipamento MVN Link. Assim, as informações foram organizadas por associações e correlações entre os elementos identificados nos estudos teóricos e práticos. A pesquisa resultou no desenvolvimento do ?Motion Capture Protocol? um protocolo que orienta o levantamento de dados com os usuários, por meio de quatro etapas (Preparar, Coletar, Remover e Determinar). Dessa forma, auxilia na gestão da coleta, tomada de decisão, medidas precisas, replicabilidade científica, bem como cuidados com o equipamento e formas corretas de armazenamento.Abstract : Design aims to improve people?s quality of life through the development of projects, which must consider the user?s capabilities and limitations. Therefore, associating Human Factors in this process allows achieving the best integration between the product and its users. However, this research raises a question: how to collect accurate and reliable data with users regarding biomechanics and kinematics, for the development of projects? In this context, motion capture can be an auxiliary resource in obtaining these objective data. However, it requires the use of systematic procedures to ensure that the data is valid. Therefore, the main objective of this research was to develop a protocol (instructions and guidelines) for the collection of objective data of biomechanics and kinematics from the motion capture by inertial sensors (MVN Link Biomech equipment from Xsens). The research was divided into four phases: Theoretical foundation; Practical Experiences; Protocol Development and Protocol Presentation. The method used consisted of an exploratory stage, with literature review and practical experiences, later descriptive and correlational for the protocol development and an explanatory step in which the protocol was applied and evaluated to be improved. Its development was carried out by the theoretical research (systematization of protocols, techniques, and methods) and practical (laboratory experiments and data collection with real users) regarding the procedures for data surveys with users involving the MVN Link equipment. Thus, the information was organized by associations and correlations between the elements identified in the theoretical and practical studies. The research resulted in the development of the 'Motion Capture Protocol' a protocol that guides the data collection with users through four steps (Prepare, Collect, Remove and Determine). In this way, it assists in the management of the data collection, decision making, precise measurements, scientific replicability, as well as equipment care and adequate storage.250 p.| il.porDesignGestão do designBiomecânicaMovimentoFatores humanos associados aos projetos de design: protocolo de coleta para a captura de movimentosinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccessORIGINALPGDE0179-D.pdfPGDE0179-D.pdfapplication/pdf17370788https://repositorio.ufsc.br/bitstream/123456789/215019/-1/PGDE0179-D.pdf9c41f62723851adc2cdc498d4c6365bfMD5-1123456789/2150192020-10-21 18:12:18.488oai:repositorio.ufsc.br:123456789/215019Repositório de PublicaçõesPUBhttp://150.162.242.35/oai/requestopendoar:23732020-10-21T21:12:18Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Fatores humanos associados aos projetos de design: protocolo de coleta para a captura de movimentos
title Fatores humanos associados aos projetos de design: protocolo de coleta para a captura de movimentos
spellingShingle Fatores humanos associados aos projetos de design: protocolo de coleta para a captura de movimentos
Varnier, Thiago
Design
Gestão do design
Biomecânica
Movimento
title_short Fatores humanos associados aos projetos de design: protocolo de coleta para a captura de movimentos
title_full Fatores humanos associados aos projetos de design: protocolo de coleta para a captura de movimentos
title_fullStr Fatores humanos associados aos projetos de design: protocolo de coleta para a captura de movimentos
title_full_unstemmed Fatores humanos associados aos projetos de design: protocolo de coleta para a captura de movimentos
title_sort Fatores humanos associados aos projetos de design: protocolo de coleta para a captura de movimentos
author Varnier, Thiago
author_facet Varnier, Thiago
author_role author
dc.contributor.none.fl_str_mv Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Varnier, Thiago
dc.contributor.advisor1.fl_str_mv Merino, Giselle Schmidt Alves Díaz
contributor_str_mv Merino, Giselle Schmidt Alves Díaz
dc.subject.classification.none.fl_str_mv Design
Gestão do design
Biomecânica
Movimento
topic Design
Gestão do design
Biomecânica
Movimento
description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Comunicação e Expressão, Programa de Pós-Graduação em Design, Florianópolis, 2019.
publishDate 2019
dc.date.issued.fl_str_mv 2019
dc.date.accessioned.fl_str_mv 2020-10-21T21:12:18Z
dc.date.available.fl_str_mv 2020-10-21T21:12:18Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://repositorio.ufsc.br/handle/123456789/215019
dc.identifier.other.none.fl_str_mv 361491
identifier_str_mv 361491
url https://repositorio.ufsc.br/handle/123456789/215019
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 250 p.| il.
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
bitstream.url.fl_str_mv https://repositorio.ufsc.br/bitstream/123456789/215019/-1/PGDE0179-D.pdf
bitstream.checksum.fl_str_mv 9c41f62723851adc2cdc498d4c6365bf
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1766805326370177024