Influência do operador sobre a capacidade do ROOT ZX localizar o forame apical
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Tipo de documento: | Trabalho de conclusão de curso |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFSC |
Texto Completo: | https://repositorio.ufsc.br/xmlui/handle/123456789/127293 |
Resumo: | TCC (graduação) - Universidade Federal de Santa Catarina. Centro de Ciências da Saúde. Odontologia. |
id |
UFSC_f8816bc72342999e995b3affc518a073 |
---|---|
oai_identifier_str |
oai:repositorio.ufsc.br:123456789/127293 |
network_acronym_str |
UFSC |
network_name_str |
Repositório Institucional da UFSC |
repository_id_str |
2373 |
spelling |
Influência do operador sobre a capacidade do ROOT ZX localizar o forame apicalConcordância entre observadoreslocalizador apical eletrônicoodontometriapreparo do canal radicularTCC (graduação) - Universidade Federal de Santa Catarina. Centro de Ciências da Saúde. Odontologia.O objetivo deste estudo foi analisar a capacidade do ROOT ZX localizar o forame apical e verificar se essa capacidade é afetada por diferentes operadores. Foram empregados 100 dentes humanos, com raízes únicas e completamente formadas. Após o acesso aos canais, os dentes foram medidos pela técnica direta por um único operador: uma lima Flexofile calibre 15 foi inserida no canal até que sua ponta fosse visualizada no bordo mais cervical do forame apical. Com a lima nesta posição, um cursor de silicone, presente no intermediário do instrumento, foi deslizado até o bordo de referência e a lima removida do canal. A distância entre o cursor e a ponta da lima foi medida com uma régua metálica com precisão de 0,5 mm, sendo a medida registrada como comprimento do dente (CD). Os dentes foram, então, medidos pelo ROOT ZX por 6 diferentes operadores. A lima foi introduzida no canal até que o aparelho acusasse que sua ponta alcançou o forame apical. A seguir, o cursor foi deslizado até o bordo de referência e, então, a lima foi retirada do canal e medida com a mesma régua, sendo a medida registrada como comprimento eletrônico/forame (CEF). As medidas eletrônicas obtidas pelos 6 operadores foram comparadas às medidas diretas. Para calcular a capacidade de o aparelho localizar o forame de cada dente, o CEF foi considerado aceitável quando coincidente com o CD ou ±0,5 mm diferente. Os percentuais de medidas eletrônicas (CEF) aceitáveis obtidos pelos diferentes operadores foram avaliados estatisticamente, num nível de significância de 5%. O teste ANOVA revelou que, independentemente do operador, não houve diferença estatística entre os comprimentos obtidos pela técnica direta (CD) e eletrônica (CEF). Segundo o teste Qui-Quadrado, houve diferenças significativas entre os operadores, sendo que o operador 3 apresentou desempenho similar ao do operador 4 e superior ao dos operadores 1, 2, 5 e 6. Foi concluído que o ROOT ZX é altamente confiável na localização do forame e que o operador exerce influência sobre o desempenho do localizador.The aim of this study was to analyze the ability of ROOT ZX to locate the apical foramen and to verify if this ability is affected by different operators. One hundred human teeth were used, with unique and fully formed roots, which have been previously used in a research with similar methodology. After access to the root canal, the teeth were measured by the direct technique by a single operator. A 15-size Flexofile file was inserted into the canal until its tip was visualized in the cervical edge of the apical foramen. With the file in this position, a silicon stop was slipped to the edge reference, and the file has been removed from the root canal. The distance between the cursor and the end of the file was measured with a metal ruler with a precision of 0.5 mm and recorded as the tooth length (TL). The teeth were measured by ROOT ZX by 6 different operators. The file was inserted into the canal until the device showed that its tip reached the apical foramen. Next, the silicon stop was slid to the edge of reference and then the file was removed from the canal and measured with the same ruler, and the measurement recorded as electronic length/foramen (ELF). The electronic measures provided by 6 operators were compared to direct measurements. To calculate the capacity of the apex locator to locate the foramen of each tooth, the ELF was considered acceptable when matched with TL or ±0.5 mm different from TL. The percentage of electronic measurements (ELF) acceptable obtained by different operators were evaluated statistically at a significance level of 5%. The ANOVA test showed that, regardless of the operator, there was no statistical differences in the mean values between the TL and ELF (the measurements with ROOT ZX). There were significant differences between the operators; the operator 3 performed better when compared to operators 1, 2, 5 and 6. It was concluded that ROOT ZX is highly reliable in locating the apical foramen and that the operator has influence on the performance of the apex locator.Florianópolis, SCFelippe, Mara CristinaUniversidade Federal de Santa CatarinaVoigt, Thaisa2014-12-09T20:00:36Z2014-12-09T20:00:36Z2014-12-02info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis44 f.application/pdfhttps://repositorio.ufsc.br/xmlui/handle/123456789/127293porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2014-12-09T20:00:36Zoai:repositorio.ufsc.br:123456789/127293Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732014-12-09T20:00:36Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false |
dc.title.none.fl_str_mv |
Influência do operador sobre a capacidade do ROOT ZX localizar o forame apical |
title |
Influência do operador sobre a capacidade do ROOT ZX localizar o forame apical |
spellingShingle |
Influência do operador sobre a capacidade do ROOT ZX localizar o forame apical Voigt, Thaisa Concordância entre observadores localizador apical eletrônico odontometria preparo do canal radicular |
title_short |
Influência do operador sobre a capacidade do ROOT ZX localizar o forame apical |
title_full |
Influência do operador sobre a capacidade do ROOT ZX localizar o forame apical |
title_fullStr |
Influência do operador sobre a capacidade do ROOT ZX localizar o forame apical |
title_full_unstemmed |
Influência do operador sobre a capacidade do ROOT ZX localizar o forame apical |
title_sort |
Influência do operador sobre a capacidade do ROOT ZX localizar o forame apical |
author |
Voigt, Thaisa |
author_facet |
Voigt, Thaisa |
author_role |
author |
dc.contributor.none.fl_str_mv |
Felippe, Mara Cristina Universidade Federal de Santa Catarina |
dc.contributor.author.fl_str_mv |
Voigt, Thaisa |
dc.subject.por.fl_str_mv |
Concordância entre observadores localizador apical eletrônico odontometria preparo do canal radicular |
topic |
Concordância entre observadores localizador apical eletrônico odontometria preparo do canal radicular |
description |
TCC (graduação) - Universidade Federal de Santa Catarina. Centro de Ciências da Saúde. Odontologia. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-12-09T20:00:36Z 2014-12-09T20:00:36Z 2014-12-02 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://repositorio.ufsc.br/xmlui/handle/123456789/127293 |
url |
https://repositorio.ufsc.br/xmlui/handle/123456789/127293 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
44 f. application/pdf |
dc.publisher.none.fl_str_mv |
Florianópolis, SC |
publisher.none.fl_str_mv |
Florianópolis, SC |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFSC instname:Universidade Federal de Santa Catarina (UFSC) instacron:UFSC |
instname_str |
Universidade Federal de Santa Catarina (UFSC) |
instacron_str |
UFSC |
institution |
UFSC |
reponame_str |
Repositório Institucional da UFSC |
collection |
Repositório Institucional da UFSC |
repository.name.fl_str_mv |
Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC) |
repository.mail.fl_str_mv |
|
_version_ |
1808652393464725504 |