Resumo: This research aims to evaluate the thermal performance of housing built with the technology of reinforced concrete walls executed on site, for use in Brazilian Bioclimatic Zone 2. The study was conducted through in situ measurements of air temperature inside the four main types of single family housing of social interest of Zilda Arns allotment, in the town of Santa Maria-RS. Measurements were made in winter and summer, with the housing closed and also with the housing closed with sealing in places susceptible to air infiltration. The evaluations were made from the relationship between changes in internal temperatures and outdoor temperatures, and considering the influences of solar orientation and air infiltration, and internal thermal comfort through a comparative analysis of temperatures with ASHRAE (2004) limits. It was observed that the solar orientation has influence during winter and summer, however the air infiltration has little influence on thermal performance of housings. It was also observed that the building system provides good thermal performance for the summer period, but is not suitable to Bioclimatic Zone 2 during winter. As for thermal comfort, the housings presented cold discomfort for the whole period of winter and presented comfort in most of the analyzed summer period.
id UFSM-20_735fdbd5124a54b0fd812db3dfab81e2
oai_identifier_str oai:repositorio.ufsm.br:1/7814
network_acronym_str UFSM-20
network_name_str Manancial - Repositório Digital da UFSM
repository_id_str 3913
spelling 2014-01-212014-01-212012-09-18CARVALHO, Paula Pereira. THERMAL PERFORMANCE OF SINGLE-FAMILY HOUSING OF SOCIAL INTEREST MADE WITH CONCRETE WALLS IN BRASILIAN BIOCLIMATIC ZONE 2. 2012. 109 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Santa Maria, Santa Maria, 2012.http://repositorio.ufsm.br/handle/1/7814This research aims to evaluate the thermal performance of housing built with the technology of reinforced concrete walls executed on site, for use in Brazilian Bioclimatic Zone 2. The study was conducted through in situ measurements of air temperature inside the four main types of single family housing of social interest of Zilda Arns allotment, in the town of Santa Maria-RS. Measurements were made in winter and summer, with the housing closed and also with the housing closed with sealing in places susceptible to air infiltration. The evaluations were made from the relationship between changes in internal temperatures and outdoor temperatures, and considering the influences of solar orientation and air infiltration, and internal thermal comfort through a comparative analysis of temperatures with ASHRAE (2004) limits. It was observed that the solar orientation has influence during winter and summer, however the air infiltration has little influence on thermal performance of housings. It was also observed that the building system provides good thermal performance for the summer period, but is not suitable to Bioclimatic Zone 2 during winter. As for thermal comfort, the housings presented cold discomfort for the whole period of winter and presented comfort in most of the analyzed summer period.O presente trabalho tem como objetivo avaliar o desempenho térmico e o conforto térmico de habitações construídas com a tecnologia de paredes de concreto armado executadas no local, para uso na Zona Bioclimática 2 brasileira. O estudo foi realizado através de medições in loco da temperatura do ar no interior de quatro unidades com orientações solares predominantes de habitações unifamiliares de interesse social do loteamento Zilda Arns, na cidade de Santa Maria-RS. Foram feitas medições no inverno e no verão, com a casa fechada e também com a casa fechada com vedação nos locais passíveis de infiltração de ar. As avaliações foram .efetuadas a partir da relação entre as variações das temperaturas internas e das temperaturas externas, considerando ainda as influências da orientação solar e da infiltração de ar, e as condições de conforto térmico internas através de uma análise comparativa de temperaturas com valores limites da ASHRAE (2004). Foi observado que a orientação solar exerce influência nos períodos de inverno e verão, porém verificou-se que a infiltração de ar pouco influencia sobre o desempenho térmico das unidades. Observou-se ainda que o sistema construtivo apresenta bom desempenho térmico para o período de verão, porém não é adequado à Zona Bioclimática 2 no período de inverno. Quanto ao conforto térmico, as habitações apresentaram desconforto por frio em todo o período analisado de inverno e conforto na maior parte do período de verão.application/pdfporUniversidade Federal de Santa MariaPrograma de Pós-Graduação em Engenharia CivilUFSMBREngenharia CivilDesempenho térmicoParedes de concretoHabitação unifamiliar de interesse socialThermal performanceConcrete wallsSingle-family housing of social interestCNPQ::ENGENHARIAS::ENGENHARIA CIVILDesempenho térmico de habitações unifamiliares de interesse social com paredes de concreto armado na zona bioclimática 2 brasileiraThermal performance of single-family housing of social interest made with concrete walls in brasilian bioclimatic zone 2info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisSantos, Joaquim Cesar Pizzutti doshttp://lattes.cnpq.br/6591314076760539Silva, Antonio Cesar Silveira Baptista dahttp://lattes.cnpq.br/8150819629082409Grigoletti, Giane de Camposhttp://lattes.cnpq.br/9725292275606192Carvalho, Paula Pereira3001000000034003003003003005fc91b32-dd4f-4466-bd1f-1b444ca5c3aedd98ec43-d08c-4e26-a084-9aef40f6fef8ed761dc7-3368-4d96-a666-d636407733358dc99c04-6e26-448e-9d50-9c72bce6cb72info:eu-repo/semantics/openAccessreponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSMORIGINALCARVALHO, PAULA PEREIRA.pdfapplication/pdf2927134http://repositorio.ufsm.br/bitstream/1/7814/1/CARVALHO%2c%20PAULA%20PEREIRA.pdf087110f8bd3dad5f636bf3ab168f76dbMD51TEXTCARVALHO, PAULA PEREIRA.pdf.txtCARVALHO, PAULA PEREIRA.pdf.txtExtracted texttext/plain170020http://repositorio.ufsm.br/bitstream/1/7814/2/CARVALHO%2c%20PAULA%20PEREIRA.pdf.txtc8d3fc866cd17503e48a5dfde67fc49aMD52THUMBNAILCARVALHO, PAULA PEREIRA.pdf.jpgCARVALHO, PAULA PEREIRA.pdf.jpgIM Thumbnailimage/jpeg5276http://repositorio.ufsm.br/bitstream/1/7814/3/CARVALHO%2c%20PAULA%20PEREIRA.pdf.jpg96f3ba696027dbd558d916696b24087aMD531/78142022-01-04 12:33:23.364oai:repositorio.ufsm.br:1/7814Repositório Institucionalhttp://repositorio.ufsm.br/PUBhttp://repositorio.ufsm.br/oai/requestopendoar:39132022-01-04T15:33:23Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.por.fl_str_mv Desempenho térmico de habitações unifamiliares de interesse social com paredes de concreto armado na zona bioclimática 2 brasileira
dc.title.alternative.eng.fl_str_mv Thermal performance of single-family housing of social interest made with concrete walls in brasilian bioclimatic zone 2
title Desempenho térmico de habitações unifamiliares de interesse social com paredes de concreto armado na zona bioclimática 2 brasileira
spellingShingle Desempenho térmico de habitações unifamiliares de interesse social com paredes de concreto armado na zona bioclimática 2 brasileira
Carvalho, Paula Pereira
Desempenho térmico
Paredes de concreto
Habitação unifamiliar de interesse social
Thermal performance
Concrete walls
Single-family housing of social interest
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
title_short Desempenho térmico de habitações unifamiliares de interesse social com paredes de concreto armado na zona bioclimática 2 brasileira
title_full Desempenho térmico de habitações unifamiliares de interesse social com paredes de concreto armado na zona bioclimática 2 brasileira
title_fullStr Desempenho térmico de habitações unifamiliares de interesse social com paredes de concreto armado na zona bioclimática 2 brasileira
title_full_unstemmed Desempenho térmico de habitações unifamiliares de interesse social com paredes de concreto armado na zona bioclimática 2 brasileira
title_sort Desempenho térmico de habitações unifamiliares de interesse social com paredes de concreto armado na zona bioclimática 2 brasileira
author Carvalho, Paula Pereira
author_facet Carvalho, Paula Pereira
author_role author
dc.contributor.advisor1.fl_str_mv Santos, Joaquim Cesar Pizzutti dos
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/6591314076760539
dc.contributor.referee1.fl_str_mv Silva, Antonio Cesar Silveira Baptista da
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/8150819629082409
dc.contributor.referee2.fl_str_mv Grigoletti, Giane de Campos
dc.contributor.referee2Lattes.fl_str_mv http://lattes.cnpq.br/9725292275606192
dc.contributor.author.fl_str_mv Carvalho, Paula Pereira
contributor_str_mv Santos, Joaquim Cesar Pizzutti dos
Silva, Antonio Cesar Silveira Baptista da
Grigoletti, Giane de Campos
dc.subject.por.fl_str_mv Desempenho térmico
Paredes de concreto
Habitação unifamiliar de interesse social
topic Desempenho térmico
Paredes de concreto
Habitação unifamiliar de interesse social
Thermal performance
Concrete walls
Single-family housing of social interest
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
dc.subject.eng.fl_str_mv Thermal performance
Concrete walls
Single-family housing of social interest
dc.subject.cnpq.fl_str_mv CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
description This research aims to evaluate the thermal performance of housing built with the technology of reinforced concrete walls executed on site, for use in Brazilian Bioclimatic Zone 2. The study was conducted through in situ measurements of air temperature inside the four main types of single family housing of social interest of Zilda Arns allotment, in the town of Santa Maria-RS. Measurements were made in winter and summer, with the housing closed and also with the housing closed with sealing in places susceptible to air infiltration. The evaluations were made from the relationship between changes in internal temperatures and outdoor temperatures, and considering the influences of solar orientation and air infiltration, and internal thermal comfort through a comparative analysis of temperatures with ASHRAE (2004) limits. It was observed that the solar orientation has influence during winter and summer, however the air infiltration has little influence on thermal performance of housings. It was also observed that the building system provides good thermal performance for the summer period, but is not suitable to Bioclimatic Zone 2 during winter. As for thermal comfort, the housings presented cold discomfort for the whole period of winter and presented comfort in most of the analyzed summer period.
publishDate 2012
dc.date.issued.fl_str_mv 2012-09-18
dc.date.accessioned.fl_str_mv 2014-01-21
dc.date.available.fl_str_mv 2014-01-21
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv CARVALHO, Paula Pereira. THERMAL PERFORMANCE OF SINGLE-FAMILY HOUSING OF SOCIAL INTEREST MADE WITH CONCRETE WALLS IN BRASILIAN BIOCLIMATIC ZONE 2. 2012. 109 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Santa Maria, Santa Maria, 2012.
dc.identifier.uri.fl_str_mv http://repositorio.ufsm.br/handle/1/7814
identifier_str_mv CARVALHO, Paula Pereira. THERMAL PERFORMANCE OF SINGLE-FAMILY HOUSING OF SOCIAL INTEREST MADE WITH CONCRETE WALLS IN BRASILIAN BIOCLIMATIC ZONE 2. 2012. 109 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Santa Maria, Santa Maria, 2012.
url http://repositorio.ufsm.br/handle/1/7814
dc.language.iso.fl_str_mv por
language por
dc.relation.cnpq.fl_str_mv 300100000003
dc.relation.confidence.fl_str_mv 400
300
300
300
300
dc.relation.authority.fl_str_mv 5fc91b32-dd4f-4466-bd1f-1b444ca5c3ae
dd98ec43-d08c-4e26-a084-9aef40f6fef8
ed761dc7-3368-4d96-a666-d63640773335
8dc99c04-6e26-448e-9d50-9c72bce6cb72
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Engenharia Civil
dc.publisher.initials.fl_str_mv UFSM
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Engenharia Civil
publisher.none.fl_str_mv Universidade Federal de Santa Maria
dc.source.none.fl_str_mv reponame:Manancial - Repositório Digital da UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Manancial - Repositório Digital da UFSM
collection Manancial - Repositório Digital da UFSM
bitstream.url.fl_str_mv http://repositorio.ufsm.br/bitstream/1/7814/1/CARVALHO%2c%20PAULA%20PEREIRA.pdf
http://repositorio.ufsm.br/bitstream/1/7814/2/CARVALHO%2c%20PAULA%20PEREIRA.pdf.txt
http://repositorio.ufsm.br/bitstream/1/7814/3/CARVALHO%2c%20PAULA%20PEREIRA.pdf.jpg
bitstream.checksum.fl_str_mv 087110f8bd3dad5f636bf3ab168f76db
c8d3fc866cd17503e48a5dfde67fc49a
96f3ba696027dbd558d916696b24087a
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv
_version_ 1801223718943326208