High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Ciência Rural |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782013000600025 |
Resumo: | To evaluate the reliability of high-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers, 20 dogs with no structural cardiac alterations at echocardiographic examination were grouped on the basis of frequency of ventricular arrhythmias, evaluated by 24-hour ambulatory ECG, and undergoing a high-resolution electrocardiography. High frequency QRS duration, duration of terminal QRS complex less than 40µV (LAS40) and root mean square voltage of the terminal 40 milliseconds of the QRS complex (RMS40) were measured. Differences in high-resolution ECG variables were not observed between groups. Therefore, the results of this investigation suggest that high-resolution electrocardiography is not a useful method for the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers without detectable myocardial alterations or systolic dysfunction. |
id |
UFSM-2_87c3db8eb17cb3e0a97e249701c18f02 |
---|---|
oai_identifier_str |
oai:scielo:S0103-84782013000600025 |
network_acronym_str |
UFSM-2 |
network_name_str |
Ciência rural (Online) |
repository_id_str |
|
spelling |
High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogslate potentialventricular arrhythmiadogTo evaluate the reliability of high-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers, 20 dogs with no structural cardiac alterations at echocardiographic examination were grouped on the basis of frequency of ventricular arrhythmias, evaluated by 24-hour ambulatory ECG, and undergoing a high-resolution electrocardiography. High frequency QRS duration, duration of terminal QRS complex less than 40µV (LAS40) and root mean square voltage of the terminal 40 milliseconds of the QRS complex (RMS40) were measured. Differences in high-resolution ECG variables were not observed between groups. Therefore, the results of this investigation suggest that high-resolution electrocardiography is not a useful method for the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers without detectable myocardial alterations or systolic dysfunction.Universidade Federal de Santa Maria2013-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782013000600025Ciência Rural v.43 n.6 2013reponame:Ciência Ruralinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM10.1590/S0103-84782013000600025info:eu-repo/semantics/openAccessPereira,Evandro ZacchéAssumpção,Thais Cristine AlvesGering,Ana PaulaGava,Fábio NelsonOrtiz,Edna Mireya GómezCamacho,Aparecido Antonioeng2014-02-21T00:00:00ZRevista |
dc.title.none.fl_str_mv |
High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs |
title |
High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs |
spellingShingle |
High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs Pereira,Evandro Zacché late potential ventricular arrhythmia dog |
title_short |
High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs |
title_full |
High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs |
title_fullStr |
High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs |
title_full_unstemmed |
High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs |
title_sort |
High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs |
author |
Pereira,Evandro Zacché |
author_facet |
Pereira,Evandro Zacché Assumpção,Thais Cristine Alves Gering,Ana Paula Gava,Fábio Nelson Ortiz,Edna Mireya Gómez Camacho,Aparecido Antonio |
author_role |
author |
author2 |
Assumpção,Thais Cristine Alves Gering,Ana Paula Gava,Fábio Nelson Ortiz,Edna Mireya Gómez Camacho,Aparecido Antonio |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Pereira,Evandro Zacché Assumpção,Thais Cristine Alves Gering,Ana Paula Gava,Fábio Nelson Ortiz,Edna Mireya Gómez Camacho,Aparecido Antonio |
dc.subject.por.fl_str_mv |
late potential ventricular arrhythmia dog |
topic |
late potential ventricular arrhythmia dog |
description |
To evaluate the reliability of high-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers, 20 dogs with no structural cardiac alterations at echocardiographic examination were grouped on the basis of frequency of ventricular arrhythmias, evaluated by 24-hour ambulatory ECG, and undergoing a high-resolution electrocardiography. High frequency QRS duration, duration of terminal QRS complex less than 40µV (LAS40) and root mean square voltage of the terminal 40 milliseconds of the QRS complex (RMS40) were measured. Differences in high-resolution ECG variables were not observed between groups. Therefore, the results of this investigation suggest that high-resolution electrocardiography is not a useful method for the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers without detectable myocardial alterations or systolic dysfunction. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782013000600025 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782013000600025 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-84782013000600025 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Universidade Federal de Santa Maria |
publisher.none.fl_str_mv |
Universidade Federal de Santa Maria |
dc.source.none.fl_str_mv |
Ciência Rural v.43 n.6 2013 reponame:Ciência Rural instname:Universidade Federal de Santa Maria (UFSM) instacron:UFSM |
instname_str |
Universidade Federal de Santa Maria (UFSM) |
instacron_str |
UFSM |
institution |
UFSM |
reponame_str |
Ciência Rural |
collection |
Ciência Rural |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1749140543317737472 |