High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs

Detalhes bibliográficos
Autor(a) principal: Pereira,Evandro Zacché
Data de Publicação: 2013
Outros Autores: Assumpção,Thais Cristine Alves, Gering,Ana Paula, Gava,Fábio Nelson, Ortiz,Edna Mireya Gómez, Camacho,Aparecido Antonio
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Ciência Rural
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782013000600025
Resumo: To evaluate the reliability of high-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers, 20 dogs with no structural cardiac alterations at echocardiographic examination were grouped on the basis of frequency of ventricular arrhythmias, evaluated by 24-hour ambulatory ECG, and undergoing a high-resolution electrocardiography. High frequency QRS duration, duration of terminal QRS complex less than 40µV (LAS40) and root mean square voltage of the terminal 40 milliseconds of the QRS complex (RMS40) were measured. Differences in high-resolution ECG variables were not observed between groups. Therefore, the results of this investigation suggest that high-resolution electrocardiography is not a useful method for the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers without detectable myocardial alterations or systolic dysfunction.
id UFSM-2_87c3db8eb17cb3e0a97e249701c18f02
oai_identifier_str oai:scielo:S0103-84782013000600025
network_acronym_str UFSM-2
network_name_str Ciência rural (Online)
repository_id_str
spelling High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogslate potentialventricular arrhythmiadogTo evaluate the reliability of high-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers, 20 dogs with no structural cardiac alterations at echocardiographic examination were grouped on the basis of frequency of ventricular arrhythmias, evaluated by 24-hour ambulatory ECG, and undergoing a high-resolution electrocardiography. High frequency QRS duration, duration of terminal QRS complex less than 40µV (LAS40) and root mean square voltage of the terminal 40 milliseconds of the QRS complex (RMS40) were measured. Differences in high-resolution ECG variables were not observed between groups. Therefore, the results of this investigation suggest that high-resolution electrocardiography is not a useful method for the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers without detectable myocardial alterations or systolic dysfunction.Universidade Federal de Santa Maria2013-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782013000600025Ciência Rural v.43 n.6 2013reponame:Ciência Ruralinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM10.1590/S0103-84782013000600025info:eu-repo/semantics/openAccessPereira,Evandro ZacchéAssumpção,Thais Cristine AlvesGering,Ana PaulaGava,Fábio NelsonOrtiz,Edna Mireya GómezCamacho,Aparecido Antonioeng2014-02-21T00:00:00ZRevista
dc.title.none.fl_str_mv High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs
title High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs
spellingShingle High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs
Pereira,Evandro Zacché
late potential
ventricular arrhythmia
dog
title_short High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs
title_full High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs
title_fullStr High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs
title_full_unstemmed High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs
title_sort High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs
author Pereira,Evandro Zacché
author_facet Pereira,Evandro Zacché
Assumpção,Thais Cristine Alves
Gering,Ana Paula
Gava,Fábio Nelson
Ortiz,Edna Mireya Gómez
Camacho,Aparecido Antonio
author_role author
author2 Assumpção,Thais Cristine Alves
Gering,Ana Paula
Gava,Fábio Nelson
Ortiz,Edna Mireya Gómez
Camacho,Aparecido Antonio
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Pereira,Evandro Zacché
Assumpção,Thais Cristine Alves
Gering,Ana Paula
Gava,Fábio Nelson
Ortiz,Edna Mireya Gómez
Camacho,Aparecido Antonio
dc.subject.por.fl_str_mv late potential
ventricular arrhythmia
dog
topic late potential
ventricular arrhythmia
dog
description To evaluate the reliability of high-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers, 20 dogs with no structural cardiac alterations at echocardiographic examination were grouped on the basis of frequency of ventricular arrhythmias, evaluated by 24-hour ambulatory ECG, and undergoing a high-resolution electrocardiography. High frequency QRS duration, duration of terminal QRS complex less than 40µV (LAS40) and root mean square voltage of the terminal 40 milliseconds of the QRS complex (RMS40) were measured. Differences in high-resolution ECG variables were not observed between groups. Therefore, the results of this investigation suggest that high-resolution electrocardiography is not a useful method for the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers without detectable myocardial alterations or systolic dysfunction.
publishDate 2013
dc.date.none.fl_str_mv 2013-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782013000600025
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782013000600025
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-84782013000600025
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
publisher.none.fl_str_mv Universidade Federal de Santa Maria
dc.source.none.fl_str_mv Ciência Rural v.43 n.6 2013
reponame:Ciência Rural
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Ciência Rural
collection Ciência Rural
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1749140543317737472