Resumo: A solid sampling flame furnace atomic absorption spectrometry (SS-FF-AAS) system was developed in this work for Mn and Ni determination in petroleum coke. The proposed solid sampling system was made in quartz, with two perpendicular tubes (T-shaped tube), adapted on the burner. Determination was made using an atomic absorption spectrometer with deuterium background corrector, using an air + acetylene flame and a single slot burner. Sample pellets up to 62 mg were introduced into the quartz device cell with a movable hollow quartz piston. When the sample pellet reaches the end of quartz cell, in the presence of oxygen flow, it quickly burns and the combustion products are transferred to the upper slot tube where the absorption atomic process happens. Calibration step was performed using aqueous standards applied directly on high purity graphite pellets and different masses of petroleum coke certified reference material (CRM). The results obtained for Mn and Ni using proposed SS-FF-AAS were compared to those obtained by inductively coupled plasma optical emission spectrometry and inductively coupled plasma mass spectrometry after sample decomposition step by microwave assisted acid digestion (high pressure) and microwave induced combustion resulting in agreement higher than 96%. In addition, the agreement for Mn and Ni in CRM (coal and petroleum coke) was 96.3 ± 8.7% and 98.2 ± 3.0%, respectively. The relative standard deviation was lower than 9% for both analytes. Characterist masses were 18.3 ± 1.8 ng for Mn and 14.7 ± 1.4 ng for Ni and limit of detection were 0.64 and 0.82 μg g-1 for Mn and Ni, respectively. The throughput was 9 determinations per hour, including drying, weighing and pressing. The proposed SS-FF-AAS system can be applied for Mn and Ni determination in petroleum coke, combining high sample throughput, precision and accuracy.
id UFSM_163441cde587f3d2249e54abd3303c90
oai_identifier_str oai:repositorio.ufsm.br:1/10582
network_acronym_str UFSM
network_name_str Manancial - Repositório Digital da UFSM
repository_id_str
spelling Espectrometria de absorção atômica com tubo aquecido na chama e amostragem direta de sólidos para determinação de manganês e níquel em coque de petróleoSolid sampling flame furnace atomic absorption spectrometry for manganese and nickel determination in petroleum cokeCoque de petróleoSS-FF-AASCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICAA solid sampling flame furnace atomic absorption spectrometry (SS-FF-AAS) system was developed in this work for Mn and Ni determination in petroleum coke. The proposed solid sampling system was made in quartz, with two perpendicular tubes (T-shaped tube), adapted on the burner. Determination was made using an atomic absorption spectrometer with deuterium background corrector, using an air + acetylene flame and a single slot burner. Sample pellets up to 62 mg were introduced into the quartz device cell with a movable hollow quartz piston. When the sample pellet reaches the end of quartz cell, in the presence of oxygen flow, it quickly burns and the combustion products are transferred to the upper slot tube where the absorption atomic process happens. Calibration step was performed using aqueous standards applied directly on high purity graphite pellets and different masses of petroleum coke certified reference material (CRM). The results obtained for Mn and Ni using proposed SS-FF-AAS were compared to those obtained by inductively coupled plasma optical emission spectrometry and inductively coupled plasma mass spectrometry after sample decomposition step by microwave assisted acid digestion (high pressure) and microwave induced combustion resulting in agreement higher than 96%. In addition, the agreement for Mn and Ni in CRM (coal and petroleum coke) was 96.3 ± 8.7% and 98.2 ± 3.0%, respectively. The relative standard deviation was lower than 9% for both analytes. Characterist masses were 18.3 ± 1.8 ng for Mn and 14.7 ± 1.4 ng for Ni and limit of detection were 0.64 and 0.82 μg g-1 for Mn and Ni, respectively. The throughput was 9 determinations per hour, including drying, weighing and pressing. The proposed SS-FF-AAS system can be applied for Mn and Ni determination in petroleum coke, combining high sample throughput, precision and accuracy.Coordenação de Aperfeiçoamento de Pessoal de Nível SuperiorNeste trabalho foi proposto um sistema de espectrometria de absorção atômica com tubo aquecido na chama e amostragem direta de sólidos (SS-FF-AAS) para a determinação de Mn e Ni em amostras de coque de petróleo. O sistema proposto para amostragem direta de sólidos foi construido em quartzo, com dois tubos perpendicularmente sobrepostos, em forma de T , adaptado a um espectrômetro de absorção atômica, com chama ar + acetileno, empregando um queimador do tipo monofenda e corretor de fundo com lâmpada de deutério. A amostra, na forma de comprimidos de até 62 mg, foi introduzida na cela de quartzo com o auxílio de um êmbolo de quartzo. Ao atingir a região da cela posicionada sobre o queimador, na presença de O2, a amostra entra em combustão e os vapores gerados são carregados até o tubo superior, onde ocorre o processo de absorção atômica. A calibração foi feita utilizando solução de referência aquosa transportada sobre comprimidos de grafite de alta pureza e, também, com diferentes massas de material de referência certificado (CRM) de coque de petróleo. Os resultados obtidos para Mn e Ni empregando o sistema SS-FF-AAS apresentaram concordância superior a 96% em comparação com resultados obtidos por espectrometria de emissão óptica com plasma indutivamente acoplado e espectrometria de massa com plasma indutivamente acoplado após decomposição das amostras por via úmida assistida por radiação micro-ondas (sistema de alta pressão) e por combustão iniciada por micro-ondas. Adicionalmente, a concordância para Mn e Ni em CRM (carvão e coque de petróleo) foi de 96,3 ± 8,7% e 98,2 ± 3,0%, respectivamente. O desvio padrão relativo foi inferior a 9% para ambos os elementos. A massa característica obtida foi de 18,3 ± 1,8 ng para Mn e de 14,7 ± 1,4 ng para Ni e o limite de detecção foi de 0,64 e 0,82 μg g-1 para Mn e Ni, respectivamente. A freqüência de determinações foi de 9 amostras por hora, incluindo as etapas de secagem, pesagem e prensagem. Desta forma, o sistema SS-FF-AAS proposto mostrou-se uma boa alternativa para determinação de Mn e Ni em coque de petróleo, agregando rapidez, precisão e exatidão.Universidade Federal de Santa MariaBRQuímicaUFSMPrograma de Pós-Graduação em QuímicaFlores, Érico Marlon de Moraeshttp://lattes.cnpq.br/7167629055579212Cassella, Ricardo Jorgensenhttp://lattes.cnpq.br/8965339627815488Müller, Edson Irineuhttp://lattes.cnpq.br/5994311290376153Bizzi, Cezar Augusto2017-05-112017-05-112009-07-28info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfapplication/pdfBIZZI, Cezar Augusto. Solid sampling flame furnace atomic absorption spectrometry for manganese and nickel determination in petroleum coke. 2009. 70 f. Dissertação (Mestrado em Química) - Universidade Federal de Santa Maria, Santa Maria, 2009.http://repositorio.ufsm.br/handle/1/10582ark:/26339/0013000006p6vporinfo:eu-repo/semantics/openAccessreponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM2023-05-11T17:18:35Zoai:repositorio.ufsm.br:1/10582Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/ONGhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.comopendoar:2023-05-11T17:18:35Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.none.fl_str_mv Espectrometria de absorção atômica com tubo aquecido na chama e amostragem direta de sólidos para determinação de manganês e níquel em coque de petróleo
Solid sampling flame furnace atomic absorption spectrometry for manganese and nickel determination in petroleum coke
title Espectrometria de absorção atômica com tubo aquecido na chama e amostragem direta de sólidos para determinação de manganês e níquel em coque de petróleo
spellingShingle Espectrometria de absorção atômica com tubo aquecido na chama e amostragem direta de sólidos para determinação de manganês e níquel em coque de petróleo
Bizzi, Cezar Augusto
Coque de petróleo
SS-FF-AAS
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Espectrometria de absorção atômica com tubo aquecido na chama e amostragem direta de sólidos para determinação de manganês e níquel em coque de petróleo
title_full Espectrometria de absorção atômica com tubo aquecido na chama e amostragem direta de sólidos para determinação de manganês e níquel em coque de petróleo
title_fullStr Espectrometria de absorção atômica com tubo aquecido na chama e amostragem direta de sólidos para determinação de manganês e níquel em coque de petróleo
title_full_unstemmed Espectrometria de absorção atômica com tubo aquecido na chama e amostragem direta de sólidos para determinação de manganês e níquel em coque de petróleo
title_sort Espectrometria de absorção atômica com tubo aquecido na chama e amostragem direta de sólidos para determinação de manganês e níquel em coque de petróleo
author Bizzi, Cezar Augusto
author_facet Bizzi, Cezar Augusto
author_role author
dc.contributor.none.fl_str_mv Flores, Érico Marlon de Moraes
http://lattes.cnpq.br/7167629055579212
Cassella, Ricardo Jorgensen
http://lattes.cnpq.br/8965339627815488
Müller, Edson Irineu
http://lattes.cnpq.br/5994311290376153
dc.contributor.author.fl_str_mv Bizzi, Cezar Augusto
dc.subject.por.fl_str_mv Coque de petróleo
SS-FF-AAS
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
topic Coque de petróleo
SS-FF-AAS
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
description A solid sampling flame furnace atomic absorption spectrometry (SS-FF-AAS) system was developed in this work for Mn and Ni determination in petroleum coke. The proposed solid sampling system was made in quartz, with two perpendicular tubes (T-shaped tube), adapted on the burner. Determination was made using an atomic absorption spectrometer with deuterium background corrector, using an air + acetylene flame and a single slot burner. Sample pellets up to 62 mg were introduced into the quartz device cell with a movable hollow quartz piston. When the sample pellet reaches the end of quartz cell, in the presence of oxygen flow, it quickly burns and the combustion products are transferred to the upper slot tube where the absorption atomic process happens. Calibration step was performed using aqueous standards applied directly on high purity graphite pellets and different masses of petroleum coke certified reference material (CRM). The results obtained for Mn and Ni using proposed SS-FF-AAS were compared to those obtained by inductively coupled plasma optical emission spectrometry and inductively coupled plasma mass spectrometry after sample decomposition step by microwave assisted acid digestion (high pressure) and microwave induced combustion resulting in agreement higher than 96%. In addition, the agreement for Mn and Ni in CRM (coal and petroleum coke) was 96.3 ± 8.7% and 98.2 ± 3.0%, respectively. The relative standard deviation was lower than 9% for both analytes. Characterist masses were 18.3 ± 1.8 ng for Mn and 14.7 ± 1.4 ng for Ni and limit of detection were 0.64 and 0.82 μg g-1 for Mn and Ni, respectively. The throughput was 9 determinations per hour, including drying, weighing and pressing. The proposed SS-FF-AAS system can be applied for Mn and Ni determination in petroleum coke, combining high sample throughput, precision and accuracy.
publishDate 2009
dc.date.none.fl_str_mv 2009-07-28
2017-05-11
2017-05-11
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv BIZZI, Cezar Augusto. Solid sampling flame furnace atomic absorption spectrometry for manganese and nickel determination in petroleum coke. 2009. 70 f. Dissertação (Mestrado em Química) - Universidade Federal de Santa Maria, Santa Maria, 2009.
http://repositorio.ufsm.br/handle/1/10582
dc.identifier.dark.fl_str_mv ark:/26339/0013000006p6v
identifier_str_mv BIZZI, Cezar Augusto. Solid sampling flame furnace atomic absorption spectrometry for manganese and nickel determination in petroleum coke. 2009. 70 f. Dissertação (Mestrado em Química) - Universidade Federal de Santa Maria, Santa Maria, 2009.
ark:/26339/0013000006p6v
url http://repositorio.ufsm.br/handle/1/10582
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
BR
Química
UFSM
Programa de Pós-Graduação em Química
publisher.none.fl_str_mv Universidade Federal de Santa Maria
BR
Química
UFSM
Programa de Pós-Graduação em Química
dc.source.none.fl_str_mv reponame:Manancial - Repositório Digital da UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Manancial - Repositório Digital da UFSM
collection Manancial - Repositório Digital da UFSM
repository.name.fl_str_mv Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv atendimento.sib@ufsm.br||tedebc@gmail.com
_version_ 1821325800837742592