Determinação de contaminantes emergentes em água utilizando microextração adsortiva em barra (BAμE) e UHPLC-MS/MS

Detalhes bibliográficos
Autor(a) principal: Souza, Maiara Priscilla de
Data de Publicação: 2016
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Manancial - Repositório Digital da UFSM
Texto Completo: http://repositorio.ufsm.br/handle/1/10632
Resumo: The emerging pollutants are substances that enter continuously in the environment and are being more recognize due to the advancement of instrumental and sample preparation techniques. These contaminants include several chemical classes, such as pharmaceuticals, hormones, personal care products, flame retardants and others. Water is one of the most susceptible matrix since the sewage discharge is one of the main routes of environmental pollution. Bar adsorptive microextration (BAμE) has shown great analytical capacity for the analysis of organic compounds in residual level and has become a well-established analytical tool in sample preparation. In this work, a simple and low cost method was validated for the analysis of 13 emerging contaminants in water using BAμE with polymeric sorbent followed by ultra high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS). The preparation, stability tests and development of BAμE devices are also discussed. Eleven different coating phases were evaluated. In order to select the best combination of experimental conditions for extraction and back extraction, central composite design (CCD) with four variables was applied. Validation results were satisfactory, since the method presented recoveries between 74% and 118% with relative standard deviations (RSD) < 19%. The analytical performance presented detection and quantification limits of 0.012 to 0.6 and 0.04 to 2 μg L-1, respectively. The proposed method combines a simple and effective sample preparation for the determination of emerging contaminants in water using a microextraction technique (BAμE) followed by UHPLC-MS/MS analysis. The method applicability was evaluated using real samples of surface, drinking and tap water and 6 positive samples were found indicating the presence of bisphenol A (0.08-0.665 μg L-1) and paracetamol (0.104-4.2 μg L-1).
id UFSM_2485f805241084b5ea735eb6373154f7
oai_identifier_str oai:repositorio.ufsm.br:1/10632
network_acronym_str UFSM
network_name_str Manancial - Repositório Digital da UFSM
repository_id_str
spelling Determinação de contaminantes emergentes em água utilizando microextração adsortiva em barra (BAμE) e UHPLC-MS/MSDetermination of emerging contaminants in water using bar adsorptive microextraction (BAμE) AND UHPLC-MS/MSContaminantes emergentesÁguaMicroextração adsortiva em barraUHPLC-MS/MSEmerging contaminantsWaterBar adsorptive microextractionUHPLC-MS/MSCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICAThe emerging pollutants are substances that enter continuously in the environment and are being more recognize due to the advancement of instrumental and sample preparation techniques. These contaminants include several chemical classes, such as pharmaceuticals, hormones, personal care products, flame retardants and others. Water is one of the most susceptible matrix since the sewage discharge is one of the main routes of environmental pollution. Bar adsorptive microextration (BAμE) has shown great analytical capacity for the analysis of organic compounds in residual level and has become a well-established analytical tool in sample preparation. In this work, a simple and low cost method was validated for the analysis of 13 emerging contaminants in water using BAμE with polymeric sorbent followed by ultra high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS). The preparation, stability tests and development of BAμE devices are also discussed. Eleven different coating phases were evaluated. In order to select the best combination of experimental conditions for extraction and back extraction, central composite design (CCD) with four variables was applied. Validation results were satisfactory, since the method presented recoveries between 74% and 118% with relative standard deviations (RSD) < 19%. The analytical performance presented detection and quantification limits of 0.012 to 0.6 and 0.04 to 2 μg L-1, respectively. The proposed method combines a simple and effective sample preparation for the determination of emerging contaminants in water using a microextraction technique (BAμE) followed by UHPLC-MS/MS analysis. The method applicability was evaluated using real samples of surface, drinking and tap water and 6 positive samples were found indicating the presence of bisphenol A (0.08-0.665 μg L-1) and paracetamol (0.104-4.2 μg L-1).Coordenação de Aperfeiçoamento de Pessoal de Nível SuperiorOs contaminantes emergentes são substâncias que entram continuamente no meio ambiente e que estão sendo reconhecidas com maior profundidade devido ao avanço de técnicas instrumentais e de preparo de amostra. Estes compostos englobam diversas classes químicas, como por exemplo, fármacos, hormônios, produtos de higiene e cuidado pessoal, retardantes de chama, dentre outros. Uma das matrizes mais suscetíveis à contaminação é a água tendo em vista que a descarga de esgoto é uma das principais vias de poluição ambiental. A microextração adsortiva em barra (BAμE) tem demonstrado grande capacidade analítica para a análise de compostos orgânicos em nível residual e vem se tornando uma ferramenta analítica bem estabelecida no âmbito de preparo de amostras. Neste estudo foi desenvolvido e validado um método simples e de baixo custo para a determinação de 13 contaminantes emergentes em água utilizando BAμE e empregando sorvente polimérico com posterior análise por cromatografia liquida de ultra eficiência acoplada à espectrometria de massas em série (UHPLC-MS/MS). O preparo das barras bem como os testes de estabilidade foram avaliados. Onze sorventes foram testados para revestir os dispositivos. A fim de avaliar a melhor combinação de parâmetros para a extração e dessorção dos analitos, utilizou-se um planejamento do composto central (CCD) com 4 variáveis. Os resultados da validação foram satisfatórios uma vez que as recuperações obtidas ficaram entre 74% e 118% com desvio padrão relativo RSD < 19%. Os limites de detecção e quantificação foram de 0,012 a 0,6 e 0,04 a 2,0 μg L-1, respectivamente. O método proposto combina uma etapa de preparo de amostra simples e eficaz para a determinação de contaminantes emergentes em água. A aplicabilidade do método foi avaliada utilizando amostras reais de água de superfície, de torneira e mineral e destas, 6 amostras apresentaram bisfenol A (0,08-0,665 μg L-1) e paracetamol (0,104-4,2 μg L-1).Universidade Federal de Santa MariaBRQuímicaUFSMPrograma de Pós-Graduação em QuímicaZanella, Renatohttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4781698T9Pizzolato, Tânia Marahttp://lattes.cnpq.br/6392594590302380Viera, Mariela de Souzahttp://lattes.cnpq.br/7717479188347962Souza, Maiara Priscilla de2017-05-182017-05-182016-08-25info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfapplication/pdfSOUZA, Maiara Priscilla de. Determination of emerging contaminants in water using bar adsorptive microextraction (BAμE) AND UHPLC-MS/MS. 2016. 94 f. Dissertação (Mestrado em Química) - Universidade Federal de Santa Maria, Santa Maria, 2016.http://repositorio.ufsm.br/handle/1/10632porinfo:eu-repo/semantics/openAccessreponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM2017-07-25T15:05:13Zoai:repositorio.ufsm.br:1/10632Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/ONGhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.comopendoar:2017-07-25T15:05:13Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.none.fl_str_mv Determinação de contaminantes emergentes em água utilizando microextração adsortiva em barra (BAμE) e UHPLC-MS/MS
Determination of emerging contaminants in water using bar adsorptive microextraction (BAμE) AND UHPLC-MS/MS
title Determinação de contaminantes emergentes em água utilizando microextração adsortiva em barra (BAμE) e UHPLC-MS/MS
spellingShingle Determinação de contaminantes emergentes em água utilizando microextração adsortiva em barra (BAμE) e UHPLC-MS/MS
Souza, Maiara Priscilla de
Contaminantes emergentes
Água
Microextração adsortiva em barra
UHPLC-MS/MS
Emerging contaminants
Water
Bar adsorptive microextraction
UHPLC-MS/MS
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Determinação de contaminantes emergentes em água utilizando microextração adsortiva em barra (BAμE) e UHPLC-MS/MS
title_full Determinação de contaminantes emergentes em água utilizando microextração adsortiva em barra (BAμE) e UHPLC-MS/MS
title_fullStr Determinação de contaminantes emergentes em água utilizando microextração adsortiva em barra (BAμE) e UHPLC-MS/MS
title_full_unstemmed Determinação de contaminantes emergentes em água utilizando microextração adsortiva em barra (BAμE) e UHPLC-MS/MS
title_sort Determinação de contaminantes emergentes em água utilizando microextração adsortiva em barra (BAμE) e UHPLC-MS/MS
author Souza, Maiara Priscilla de
author_facet Souza, Maiara Priscilla de
author_role author
dc.contributor.none.fl_str_mv Zanella, Renato
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4781698T9
Pizzolato, Tânia Mara
http://lattes.cnpq.br/6392594590302380
Viera, Mariela de Souza
http://lattes.cnpq.br/7717479188347962
dc.contributor.author.fl_str_mv Souza, Maiara Priscilla de
dc.subject.por.fl_str_mv Contaminantes emergentes
Água
Microextração adsortiva em barra
UHPLC-MS/MS
Emerging contaminants
Water
Bar adsorptive microextraction
UHPLC-MS/MS
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
topic Contaminantes emergentes
Água
Microextração adsortiva em barra
UHPLC-MS/MS
Emerging contaminants
Water
Bar adsorptive microextraction
UHPLC-MS/MS
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
description The emerging pollutants are substances that enter continuously in the environment and are being more recognize due to the advancement of instrumental and sample preparation techniques. These contaminants include several chemical classes, such as pharmaceuticals, hormones, personal care products, flame retardants and others. Water is one of the most susceptible matrix since the sewage discharge is one of the main routes of environmental pollution. Bar adsorptive microextration (BAμE) has shown great analytical capacity for the analysis of organic compounds in residual level and has become a well-established analytical tool in sample preparation. In this work, a simple and low cost method was validated for the analysis of 13 emerging contaminants in water using BAμE with polymeric sorbent followed by ultra high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS). The preparation, stability tests and development of BAμE devices are also discussed. Eleven different coating phases were evaluated. In order to select the best combination of experimental conditions for extraction and back extraction, central composite design (CCD) with four variables was applied. Validation results were satisfactory, since the method presented recoveries between 74% and 118% with relative standard deviations (RSD) < 19%. The analytical performance presented detection and quantification limits of 0.012 to 0.6 and 0.04 to 2 μg L-1, respectively. The proposed method combines a simple and effective sample preparation for the determination of emerging contaminants in water using a microextraction technique (BAμE) followed by UHPLC-MS/MS analysis. The method applicability was evaluated using real samples of surface, drinking and tap water and 6 positive samples were found indicating the presence of bisphenol A (0.08-0.665 μg L-1) and paracetamol (0.104-4.2 μg L-1).
publishDate 2016
dc.date.none.fl_str_mv 2016-08-25
2017-05-18
2017-05-18
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv SOUZA, Maiara Priscilla de. Determination of emerging contaminants in water using bar adsorptive microextraction (BAμE) AND UHPLC-MS/MS. 2016. 94 f. Dissertação (Mestrado em Química) - Universidade Federal de Santa Maria, Santa Maria, 2016.
http://repositorio.ufsm.br/handle/1/10632
identifier_str_mv SOUZA, Maiara Priscilla de. Determination of emerging contaminants in water using bar adsorptive microextraction (BAμE) AND UHPLC-MS/MS. 2016. 94 f. Dissertação (Mestrado em Química) - Universidade Federal de Santa Maria, Santa Maria, 2016.
url http://repositorio.ufsm.br/handle/1/10632
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
BR
Química
UFSM
Programa de Pós-Graduação em Química
publisher.none.fl_str_mv Universidade Federal de Santa Maria
BR
Química
UFSM
Programa de Pós-Graduação em Química
dc.source.none.fl_str_mv reponame:Manancial - Repositório Digital da UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Manancial - Repositório Digital da UFSM
collection Manancial - Repositório Digital da UFSM
repository.name.fl_str_mv Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv atendimento.sib@ufsm.br||tedebc@gmail.com
_version_ 1805922026647453696