Precisão de coordenadas planimétricas obtidas com receptores GNSS de pontos situados sob redes elétricas de alta tensão

Detalhes bibliográficos
Autor(a) principal: Hillebrand, Fernando Luis
Data de Publicação: 2012
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Manancial - Repositório Digital da UFSM
Texto Completo: http://repositorio.ufsm.br/handle/1/9573
Resumo: The purpose of this work was investigate and measure the possibility to exist multipath caused by the corona noise generated in high voltage electric lines recepting GNSS signals. Experiments were realized with a 69 kV tension electric line localized in Santa Maria/RS. A serie was located with eleven transversal points to the longitudinal ranging of the transmission line. In this points, the eletromagnetic field was estimated using an equipment to measure the electromagnetic field EM-8000 model. Valuations was realized about the interferences on positioning by the absolut method, using a GNSS receiver with C/A code Garmin GPS II Plus model and the positioning by the relative method with the GNSS receiver L1/L2 Topcon Hiper model. To estimate the interference in the points was necessary to obtain the geodesic coordinates of this points without multipath possibilities caused of corona noise. For this was implanted a squared topographical polygonal where the support points were located far from the transmission lines, free of the electromagnetic field influence. Calculating the variances among the coordinates was necessary transform the geodesic coordinates obtained at GNSS receivers to the Local Topographic System, to make the systems compatible, using the rotation and translation model. Calculating was possible conclude that to the raising method and the geodesic equipment used in this experiment, in a 69 kV transmission line, the found discrepancies were in the standard deviation of 17,10 mm admitted to equipment GNSS receiver L1/L2 and 15 mm to GNSS receiver C/A code, in a 95% confidence level. So it was not evidenced interferences in the electromagnetic field at GNSS signal reception.
id UFSM_4c3401b805f3b832bf3455d8be9a9048
oai_identifier_str oai:repositorio.ufsm.br:1/9573
network_acronym_str UFSM
network_name_str Manancial - Repositório Digital da UFSM
repository_id_str
spelling Precisão de coordenadas planimétricas obtidas com receptores GNSS de pontos situados sob redes elétricas de alta tensãoPlanimetric coordinate accuracy obtained with GNSS receivers located in points under high voltage electrical linesPoligonal topográficaReceptores GNSSRede elétricaEfeito coronaMulticaminhamento dos sinais GNSSTopographical polygonalGNSS receiversElectric linesCorona noiseGNSS signal multipathCNPQ::CIENCIAS EXATAS E DA TERRA::GEOCIENCIASThe purpose of this work was investigate and measure the possibility to exist multipath caused by the corona noise generated in high voltage electric lines recepting GNSS signals. Experiments were realized with a 69 kV tension electric line localized in Santa Maria/RS. A serie was located with eleven transversal points to the longitudinal ranging of the transmission line. In this points, the eletromagnetic field was estimated using an equipment to measure the electromagnetic field EM-8000 model. Valuations was realized about the interferences on positioning by the absolut method, using a GNSS receiver with C/A code Garmin GPS II Plus model and the positioning by the relative method with the GNSS receiver L1/L2 Topcon Hiper model. To estimate the interference in the points was necessary to obtain the geodesic coordinates of this points without multipath possibilities caused of corona noise. For this was implanted a squared topographical polygonal where the support points were located far from the transmission lines, free of the electromagnetic field influence. Calculating the variances among the coordinates was necessary transform the geodesic coordinates obtained at GNSS receivers to the Local Topographic System, to make the systems compatible, using the rotation and translation model. Calculating was possible conclude that to the raising method and the geodesic equipment used in this experiment, in a 69 kV transmission line, the found discrepancies were in the standard deviation of 17,10 mm admitted to equipment GNSS receiver L1/L2 and 15 mm to GNSS receiver C/A code, in a 95% confidence level. So it was not evidenced interferences in the electromagnetic field at GNSS signal reception.O propósito deste trabalho foi investigar e mensurar a possibilidade de haver multicaminhamento pelo efeito corona gerado em linhas elétricas de alta tensão na recepção de sinais GNSS. Foram realizados experimentos em uma rede elétrica com tensão de 69 kV localizado no município de Santa Maria/RS. Foi implantada uma série de onze pontos transversais ao alinhamento longitudinal da linha de transmissão. Nestes pontos realizou-se uma avaliação do campo eletromagnético gerado utilizando um equipamento medidor de campo eletromagnético modelo EM- 8000. Foram realizadas avaliações da interferência no posicionamento pelo método absoluto utilizando o receptor GNSS de código C/A Garmin modelo GPS II Plus e o posicionamento pelo método relativo com o receptor GNSS portadora L1/L2 Topcon modelo Hiper. Para avaliar a interferência dos pontos foi necessário obter as coordenadas geodésicas desses pontos sem possibilidades de multicaminhamento pelo efeito corona. Para isto implantou-se uma poligonal topográfica enquadrada em que os marcos de apoio localizavam-se distantes a linha de transmissão sem a influência do campo eletromagnético. Ao realizar o cálculo das discrepâncias entre as coordenadas foi necessário realizar a transformação das coordenadas geodésicas obtidas pelos receptores GNSS para o Sistema Topográfico Local para a compatibilização dos sistemas, sendo utilizado o modelo das rotações e translações. Realizando os cálculos concluiu-se que para os métodos de levantamento e os equipamentos geodésicos utilizados neste experimento, em uma linha de transmissão de 69 kV, as discrepâncias constatadas ficaram dentro do desviospadrões de 17,10 mm admitido ao equipamento receptor GNSS portadora L1/L2 e 15 m ao receptor GNSS código C/A, a nível de confiança de 95%. Assim não se constatou interferências do campo eletromagnético na recepção dos sinais GNSS.Universidade Federal de Santa MariaBRGeociênciasUFSMPrograma de Pós-Graduação em GeomáticaDal'Forno, Gelson Laurohttp://lattes.cnpq.br/8170266741593551Farret, Felix Albertohttp://lattes.cnpq.br/5783619992936443Veronez, Mauricio Robertohttp://lattes.cnpq.br/0157177135951013Hillebrand, Fernando Luis2013-09-022013-09-022012-09-17info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfapplication/pdfHILLEBRAND, Fernando Luis. Planimetric coordinate accuracy obtained with GNSS receivers located in points under high voltage electrical lines. 2012. 91 f. Dissertação (Mestrado em Geociências) - Universidade Federal de Santa Maria, Santa Maria, 2012.http://repositorio.ufsm.br/handle/1/9573porinfo:eu-repo/semantics/openAccessreponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM2023-05-29T19:38:37Zoai:repositorio.ufsm.br:1/9573Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/ONGhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.comopendoar:2023-05-29T19:38:37Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.none.fl_str_mv Precisão de coordenadas planimétricas obtidas com receptores GNSS de pontos situados sob redes elétricas de alta tensão
Planimetric coordinate accuracy obtained with GNSS receivers located in points under high voltage electrical lines
title Precisão de coordenadas planimétricas obtidas com receptores GNSS de pontos situados sob redes elétricas de alta tensão
spellingShingle Precisão de coordenadas planimétricas obtidas com receptores GNSS de pontos situados sob redes elétricas de alta tensão
Hillebrand, Fernando Luis
Poligonal topográfica
Receptores GNSS
Rede elétrica
Efeito corona
Multicaminhamento dos sinais GNSS
Topographical polygonal
GNSS receivers
Electric lines
Corona noise
GNSS signal multipath
CNPQ::CIENCIAS EXATAS E DA TERRA::GEOCIENCIAS
title_short Precisão de coordenadas planimétricas obtidas com receptores GNSS de pontos situados sob redes elétricas de alta tensão
title_full Precisão de coordenadas planimétricas obtidas com receptores GNSS de pontos situados sob redes elétricas de alta tensão
title_fullStr Precisão de coordenadas planimétricas obtidas com receptores GNSS de pontos situados sob redes elétricas de alta tensão
title_full_unstemmed Precisão de coordenadas planimétricas obtidas com receptores GNSS de pontos situados sob redes elétricas de alta tensão
title_sort Precisão de coordenadas planimétricas obtidas com receptores GNSS de pontos situados sob redes elétricas de alta tensão
author Hillebrand, Fernando Luis
author_facet Hillebrand, Fernando Luis
author_role author
dc.contributor.none.fl_str_mv Dal'Forno, Gelson Lauro
http://lattes.cnpq.br/8170266741593551
Farret, Felix Alberto
http://lattes.cnpq.br/5783619992936443
Veronez, Mauricio Roberto
http://lattes.cnpq.br/0157177135951013
dc.contributor.author.fl_str_mv Hillebrand, Fernando Luis
dc.subject.por.fl_str_mv Poligonal topográfica
Receptores GNSS
Rede elétrica
Efeito corona
Multicaminhamento dos sinais GNSS
Topographical polygonal
GNSS receivers
Electric lines
Corona noise
GNSS signal multipath
CNPQ::CIENCIAS EXATAS E DA TERRA::GEOCIENCIAS
topic Poligonal topográfica
Receptores GNSS
Rede elétrica
Efeito corona
Multicaminhamento dos sinais GNSS
Topographical polygonal
GNSS receivers
Electric lines
Corona noise
GNSS signal multipath
CNPQ::CIENCIAS EXATAS E DA TERRA::GEOCIENCIAS
description The purpose of this work was investigate and measure the possibility to exist multipath caused by the corona noise generated in high voltage electric lines recepting GNSS signals. Experiments were realized with a 69 kV tension electric line localized in Santa Maria/RS. A serie was located with eleven transversal points to the longitudinal ranging of the transmission line. In this points, the eletromagnetic field was estimated using an equipment to measure the electromagnetic field EM-8000 model. Valuations was realized about the interferences on positioning by the absolut method, using a GNSS receiver with C/A code Garmin GPS II Plus model and the positioning by the relative method with the GNSS receiver L1/L2 Topcon Hiper model. To estimate the interference in the points was necessary to obtain the geodesic coordinates of this points without multipath possibilities caused of corona noise. For this was implanted a squared topographical polygonal where the support points were located far from the transmission lines, free of the electromagnetic field influence. Calculating the variances among the coordinates was necessary transform the geodesic coordinates obtained at GNSS receivers to the Local Topographic System, to make the systems compatible, using the rotation and translation model. Calculating was possible conclude that to the raising method and the geodesic equipment used in this experiment, in a 69 kV transmission line, the found discrepancies were in the standard deviation of 17,10 mm admitted to equipment GNSS receiver L1/L2 and 15 mm to GNSS receiver C/A code, in a 95% confidence level. So it was not evidenced interferences in the electromagnetic field at GNSS signal reception.
publishDate 2012
dc.date.none.fl_str_mv 2012-09-17
2013-09-02
2013-09-02
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv HILLEBRAND, Fernando Luis. Planimetric coordinate accuracy obtained with GNSS receivers located in points under high voltage electrical lines. 2012. 91 f. Dissertação (Mestrado em Geociências) - Universidade Federal de Santa Maria, Santa Maria, 2012.
http://repositorio.ufsm.br/handle/1/9573
identifier_str_mv HILLEBRAND, Fernando Luis. Planimetric coordinate accuracy obtained with GNSS receivers located in points under high voltage electrical lines. 2012. 91 f. Dissertação (Mestrado em Geociências) - Universidade Federal de Santa Maria, Santa Maria, 2012.
url http://repositorio.ufsm.br/handle/1/9573
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
BR
Geociências
UFSM
Programa de Pós-Graduação em Geomática
publisher.none.fl_str_mv Universidade Federal de Santa Maria
BR
Geociências
UFSM
Programa de Pós-Graduação em Geomática
dc.source.none.fl_str_mv reponame:Manancial - Repositório Digital da UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Manancial - Repositório Digital da UFSM
collection Manancial - Repositório Digital da UFSM
repository.name.fl_str_mv Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv atendimento.sib@ufsm.br||tedebc@gmail.com
_version_ 1805922138862911488