Uso de modelos multivariados para a avaliação do valor de dienos em amostras de gasolina de pirólise

Detalhes bibliográficos
Autor(a) principal: Hilgemann, Maurício
Data de Publicação: 2005
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Manancial - Repositório Digital da UFSM
dARK ID: ark:/26339/00130000188xg
Texto Completo: http://repositorio.ufsm.br/handle/1/10380
Resumo: The quality of gasoline may be affected by the presence of several compounds. Among them, the conjugated dienes play an important role due to the fact that their presence is strongly associated with gum formation, which may clogs the injector of automobiles and may causes damages in the petroleum derivates. The main used method for the determination of total conjugated dienes is the UOP-326 method. However, the long analysis time (from 5 to 6 hours) is the main disadvantages. The available methodologies investigated as alternative to the UOP-326 method do not solve the problem properly. The present work reports the use of multivariate models to assess the diene value (DV) in pyrolysis gasoline samples starting from voltammetric and spectrophotometric data. The calibrations were carried out using the UOP-326 method instead of diene standards. In the voltammetric model, starting from a group of 24 hydrogenated pyrolysis gasoline, the PLS (Partial Least Squares) method was used to predict the DV in an independent group of 7 samples. The deviations observed were lower than 12,2% comparing to the UOP-326 method. In a group of 24 non-hydrogenated pyrolysis gasoline samples, an independent group of 7 samples was also used to predict the DV. The deviations observed were lower than 4,1%. In the spectrophotometric approach, the PLS method was used to predict the DV in an independent group of 5 samples of hydrogenated pyrolysis gasoline (n=21). The deviations observed were lower than 11% by comparing to the UOP-326 method. In a group of 26 non-hydrogenated pyrolysis gasoline samples, an independent group of 10 samples was used to predict the DV. The deviations observed were lower than 5,7%. Comparing the voltammetric and spectrophotometric methods, the former showed more reliable results with lower RMSEP (Root Mean Square Error of Prediction) values.
id UFSM_8896c2da404135c927537a0a10f0463e
oai_identifier_str oai:repositorio.ufsm.br:1/10380
network_acronym_str UFSM
network_name_str Manancial - Repositório Digital da UFSM
repository_id_str
spelling Uso de modelos multivariados para a avaliação do valor de dienos em amostras de gasolina de piróliseChemometric approach to assess the diene value in pyrolysis gasolineGasolina de piróliseValor de dienosMétodo PLSPyrolysis gasolineDiene valuePLS methodCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICAThe quality of gasoline may be affected by the presence of several compounds. Among them, the conjugated dienes play an important role due to the fact that their presence is strongly associated with gum formation, which may clogs the injector of automobiles and may causes damages in the petroleum derivates. The main used method for the determination of total conjugated dienes is the UOP-326 method. However, the long analysis time (from 5 to 6 hours) is the main disadvantages. The available methodologies investigated as alternative to the UOP-326 method do not solve the problem properly. The present work reports the use of multivariate models to assess the diene value (DV) in pyrolysis gasoline samples starting from voltammetric and spectrophotometric data. The calibrations were carried out using the UOP-326 method instead of diene standards. In the voltammetric model, starting from a group of 24 hydrogenated pyrolysis gasoline, the PLS (Partial Least Squares) method was used to predict the DV in an independent group of 7 samples. The deviations observed were lower than 12,2% comparing to the UOP-326 method. In a group of 24 non-hydrogenated pyrolysis gasoline samples, an independent group of 7 samples was also used to predict the DV. The deviations observed were lower than 4,1%. In the spectrophotometric approach, the PLS method was used to predict the DV in an independent group of 5 samples of hydrogenated pyrolysis gasoline (n=21). The deviations observed were lower than 11% by comparing to the UOP-326 method. In a group of 26 non-hydrogenated pyrolysis gasoline samples, an independent group of 10 samples was used to predict the DV. The deviations observed were lower than 5,7%. Comparing the voltammetric and spectrophotometric methods, the former showed more reliable results with lower RMSEP (Root Mean Square Error of Prediction) values.Conselho Nacional de Desenvolvimento Científico e TecnológicoA qualidade da gasolina é afetada pela presença de diversos compostos. Entre eles, os dienos conjugados possuem um importante papel devido ao fato de estarem associados à formação de goma, que forma depósitos no injetor de combustível de automóveis e diminui a qualidade dos produtos petrolíferos. O método comumente utilizado para a determinação de dienos conjugados totais é o método UOP-326. Contudo, ele apresenta como principal desvantagem o longo tempo de análise (de 5 a 6 horas). As metodologias já investigadas que visam substituir o método UOP-326 na quantificação de dienos conjugados em gasolina não resolvem adequadamente o problema. Dessa forma, o presente trabalho aborda o uso de modelos multivariados para a avaliação do valor de dienos (DV) em amostras de gasolina de pirólise a partir de dados voltamétricos e espectrofotométricos, utilizando o método UOP-326 para a calibração do sistema. No modelo voltamétrico, de um grupo de 24 amostras de gasolina de pirólise hidrogenada, utilizou-se o método PLS (Regressão por Mínimos Quadrados Parciais) para a predição do DV em um grupo independente de 7 amostras, obtendo-se desvios inferiores a 12,2% quando comparado ao método UOP-326. E em 24 amostras de gasolina de pirólise não hidrogenada, um grupo independente de 7 amostras foi utilizado para a predição do DV, obtendo desvios inferiores a 4,1%. No modelo espectrofotométrico, utilizou-se o método PLS para a predição do DV em um grupo independente de 5 amostras de gasolina de pirólise hidrogenada (n=21), obtendo-se desvios inferiores a 11% quando comparado ao método UOP-326. E em 26 amostras de gasolina de pirólise não hidrogenada, um grupo independente de 10 amostras foi utilizado para a predição do DV, obtendo-se desvios inferiores a 5,7%. Na comparação entre os métodos voltamétrico e espectrofotométrico, o primeiro mostrou-se mais confiável, apresentando valores de RMSEP (erro médio dos resíduos quadráticos de predição) inferiores para ambas as amostras.Universidade Federal de Santa MariaBRQuímicaUFSMPrograma de Pós-Graduação em QuímicaNascimento, Paulo Cícero dohttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4788664D2Carvalho, Leandro Machado dehttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4795379U4Garcia, Solange Cristinahttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4790220Y7Hilgemann, Maurício2017-05-192017-05-192005-12-19info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfapplication/pdfHILGEMANN, Maurício. Chemometric approach to assess the diene value in pyrolysis gasoline. 2005. 79 f. Dissertação (Mestrado em Química) - Universidade Federal de Santa Maria, Santa Maria, 2005.http://repositorio.ufsm.br/handle/1/10380ark:/26339/00130000188xgporinfo:eu-repo/semantics/openAccessreponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM2018-01-26T04:22:31Zoai:repositorio.ufsm.br:1/10380Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/ONGhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.comopendoar:2018-01-26T04:22:31Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.none.fl_str_mv Uso de modelos multivariados para a avaliação do valor de dienos em amostras de gasolina de pirólise
Chemometric approach to assess the diene value in pyrolysis gasoline
title Uso de modelos multivariados para a avaliação do valor de dienos em amostras de gasolina de pirólise
spellingShingle Uso de modelos multivariados para a avaliação do valor de dienos em amostras de gasolina de pirólise
Hilgemann, Maurício
Gasolina de pirólise
Valor de dienos
Método PLS
Pyrolysis gasoline
Diene value
PLS method
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Uso de modelos multivariados para a avaliação do valor de dienos em amostras de gasolina de pirólise
title_full Uso de modelos multivariados para a avaliação do valor de dienos em amostras de gasolina de pirólise
title_fullStr Uso de modelos multivariados para a avaliação do valor de dienos em amostras de gasolina de pirólise
title_full_unstemmed Uso de modelos multivariados para a avaliação do valor de dienos em amostras de gasolina de pirólise
title_sort Uso de modelos multivariados para a avaliação do valor de dienos em amostras de gasolina de pirólise
author Hilgemann, Maurício
author_facet Hilgemann, Maurício
author_role author
dc.contributor.none.fl_str_mv Nascimento, Paulo Cícero do
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4788664D2
Carvalho, Leandro Machado de
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4795379U4
Garcia, Solange Cristina
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4790220Y7
dc.contributor.author.fl_str_mv Hilgemann, Maurício
dc.subject.por.fl_str_mv Gasolina de pirólise
Valor de dienos
Método PLS
Pyrolysis gasoline
Diene value
PLS method
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
topic Gasolina de pirólise
Valor de dienos
Método PLS
Pyrolysis gasoline
Diene value
PLS method
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
description The quality of gasoline may be affected by the presence of several compounds. Among them, the conjugated dienes play an important role due to the fact that their presence is strongly associated with gum formation, which may clogs the injector of automobiles and may causes damages in the petroleum derivates. The main used method for the determination of total conjugated dienes is the UOP-326 method. However, the long analysis time (from 5 to 6 hours) is the main disadvantages. The available methodologies investigated as alternative to the UOP-326 method do not solve the problem properly. The present work reports the use of multivariate models to assess the diene value (DV) in pyrolysis gasoline samples starting from voltammetric and spectrophotometric data. The calibrations were carried out using the UOP-326 method instead of diene standards. In the voltammetric model, starting from a group of 24 hydrogenated pyrolysis gasoline, the PLS (Partial Least Squares) method was used to predict the DV in an independent group of 7 samples. The deviations observed were lower than 12,2% comparing to the UOP-326 method. In a group of 24 non-hydrogenated pyrolysis gasoline samples, an independent group of 7 samples was also used to predict the DV. The deviations observed were lower than 4,1%. In the spectrophotometric approach, the PLS method was used to predict the DV in an independent group of 5 samples of hydrogenated pyrolysis gasoline (n=21). The deviations observed were lower than 11% by comparing to the UOP-326 method. In a group of 26 non-hydrogenated pyrolysis gasoline samples, an independent group of 10 samples was used to predict the DV. The deviations observed were lower than 5,7%. Comparing the voltammetric and spectrophotometric methods, the former showed more reliable results with lower RMSEP (Root Mean Square Error of Prediction) values.
publishDate 2005
dc.date.none.fl_str_mv 2005-12-19
2017-05-19
2017-05-19
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv HILGEMANN, Maurício. Chemometric approach to assess the diene value in pyrolysis gasoline. 2005. 79 f. Dissertação (Mestrado em Química) - Universidade Federal de Santa Maria, Santa Maria, 2005.
http://repositorio.ufsm.br/handle/1/10380
dc.identifier.dark.fl_str_mv ark:/26339/00130000188xg
identifier_str_mv HILGEMANN, Maurício. Chemometric approach to assess the diene value in pyrolysis gasoline. 2005. 79 f. Dissertação (Mestrado em Química) - Universidade Federal de Santa Maria, Santa Maria, 2005.
ark:/26339/00130000188xg
url http://repositorio.ufsm.br/handle/1/10380
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
BR
Química
UFSM
Programa de Pós-Graduação em Química
publisher.none.fl_str_mv Universidade Federal de Santa Maria
BR
Química
UFSM
Programa de Pós-Graduação em Química
dc.source.none.fl_str_mv reponame:Manancial - Repositório Digital da UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Manancial - Repositório Digital da UFSM
collection Manancial - Repositório Digital da UFSM
repository.name.fl_str_mv Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv atendimento.sib@ufsm.br||tedebc@gmail.com
_version_ 1815172470657777664