Resistividade elétrica de concretos de cimento Portland branco e elevados teores de escória de alto forno

Detalhes bibliográficos
Autor(a) principal: Lübeck, André
Data de Publicação: 2008
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações do UFSM
Texto Completo: http://repositorio.ufsm.br/handle/1/7691
Resumo: The electrical resistivity is an important concrete property that allows evaluating the access facility of aggressive agents before the corrosion process begins and estimates the velocity of the same process after it begun. The electrical resistivity and the oxygen availability are the characteristics that control the corrosion velocity. This work aimed to evaluate the performance of white Portland cement concretes with high blast furnace slag content and chemical activation on the electrical resistivity. Other properties were measured, as axial compressive strength, porosity and specific electrical conductivity of pore solution. Four mixtures were tested, a reference one, only with white Portland cement as binder, a second one, with 50% of blast furnace slag in substitution of cement, other with 70% slag content, and the last one, with 50% of slag and alkaline activation, 4% of Na2SO4. The water/binder ratios were fixed at 0,30, 0,42 and 0,55 for all samples. The electrical resistivity was measured using the four electrode method (Wenner method). The sample age, water/binder ratio and the slag content have an expressive effect over the electrical resistivity, especially because it results in changes of the pore structure. The electrical resistivity grows as the amount of slag increases. The increase of slag amount also results in smaller specific electrical conductivity of pore solution and pore structure refinement. On the other hand, the axial compressive strength decreases as the slag amount increases. The biggest resistivity results were obtained for the mixture with 70% of slag. This mixture showed the best cost/benefit ratio as compressive strength were fixed at 35 and 55 MPa, at 28 days, and 60 MPa, at 91 days.
id UFSM_d601a62a6703bbc9ecb47ac64a973251
oai_identifier_str oai:repositorio.ufsm.br:1/7691
network_acronym_str UFSM
network_name_str Biblioteca Digital de Teses e Dissertações do UFSM
repository_id_str
spelling 2008-06-162008-06-162008-03-03LÜBECK, André. ELECTRICAL RESISTIVITY OF WHITE PORTLAND CEMENT CONCRETES AND HIGH BLAST FURNACE SLAG CONTENT. 2008. 142 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Santa Maria, Santa Maria, 2008.http://repositorio.ufsm.br/handle/1/7691The electrical resistivity is an important concrete property that allows evaluating the access facility of aggressive agents before the corrosion process begins and estimates the velocity of the same process after it begun. The electrical resistivity and the oxygen availability are the characteristics that control the corrosion velocity. This work aimed to evaluate the performance of white Portland cement concretes with high blast furnace slag content and chemical activation on the electrical resistivity. Other properties were measured, as axial compressive strength, porosity and specific electrical conductivity of pore solution. Four mixtures were tested, a reference one, only with white Portland cement as binder, a second one, with 50% of blast furnace slag in substitution of cement, other with 70% slag content, and the last one, with 50% of slag and alkaline activation, 4% of Na2SO4. The water/binder ratios were fixed at 0,30, 0,42 and 0,55 for all samples. The electrical resistivity was measured using the four electrode method (Wenner method). The sample age, water/binder ratio and the slag content have an expressive effect over the electrical resistivity, especially because it results in changes of the pore structure. The electrical resistivity grows as the amount of slag increases. The increase of slag amount also results in smaller specific electrical conductivity of pore solution and pore structure refinement. On the other hand, the axial compressive strength decreases as the slag amount increases. The biggest resistivity results were obtained for the mixture with 70% of slag. This mixture showed the best cost/benefit ratio as compressive strength were fixed at 35 and 55 MPa, at 28 days, and 60 MPa, at 91 days.A resistividade elétrica é uma importante propriedade do concreto por permitir avaliar a facilidade de acesso de agentes agressivos antes de instalado o processo corrosivo e estimar a velocidade do mesmo depois de instalado, sendo conjuntamente com a disponibilidade de oxigênio um dos parâmetros determinantes para a velocidade da corrosão. Este trabalho teve como objetivo avaliar o desempenho de concretos de cimento Portland branco com elevados teores de escória de alto forno e ativação química quanto à resistividade elétrica aparente. Foram avaliadas além da resistividade outras grandezas como resistência à compressão, porosidade e condutividade específica da solução dos poros. Foram investigadas quatro misturas, uma de referência contendo apenas cimento, uma segunda com teor de substituição de cimento por escória de 50%, outra com teor de substituição de 70% e uma última contendo 50% de escória e ativador alcalino, Na2SO4, em um teor de 4%. As relações água/aglomerante foram fixadas em 0,30, 0,42 e 0,55 para todas as misturas. A medida da resistividade elétrica foi realizada através do método dos quatro eletrodos (Wenner). A resistividade elétrica se mostrou dependente da idade, relação a/ag e teor de escória, principalmente, em função das alterações que estas proporcionam na estrutura de poros da pasta. A resistividade cresceu proporcionalmente ao aumento do teor de escória. O aumento do teor de escória resultou também em menor condutividade da solução aquosa e refinamento da estrutura de poros da pasta. Por outro lado, a resistência à compressão diminuiu com o crescimento do teor de escória. Os maiores valores de resistividade elétrica foram apresentados pela mistura contendo 70% de escória. Esta mistura se mostrou a de melhor relação custo/benefício quando se fixaram valores de resistência à compressão de 35 e 55 MPa, aos 28 dias, e 60 MPa, aos 91 dias.application/pdfporUniversidade Federal de Santa MariaPrograma de Pós-Graduação em Engenharia CivilUFSMBREngenharia CivilConcretoResistividade elétricaCimento Portland brancoEscória de alto fornoConcreteElectrical resistivityWhite Portland cementBlast furnace slagCNPQ::ENGENHARIAS::ENGENHARIA CIVILResistividade elétrica de concretos de cimento Portland branco e elevados teores de escória de alto fornoElectrical resistivity of white Portland cement concretes and high blast furnace slag contentinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisGastaldini, Antonio Luiz Guerrahttp://lattes.cnpq.br/9293085240832049Cervo, Tatiana Cureauhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4767432H6Kazmierczak, Claudio de Souzahttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4787715T4http://lattes.cnpq.br/7511022637484145Lübeck, André3001000000034003003003003006a6bd4d6-e9f2-46f6-9245-5aefb19c7a28bb3198fe-a0ee-4ce7-92c7-b9a63722dce805e1fbb9-96a8-4d37-a468-44e3ad60f72f15e1730c-aa0f-48ec-964e-73c3c2d36f6cinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações do UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSMORIGINALANDRELUBECK.pdfapplication/pdf2639194http://repositorio.ufsm.br/bitstream/1/7691/1/ANDRELUBECK.pdfa5425fd4f3ffc27d3c84d7f8af88afe7MD51TEXTANDRELUBECK.pdf.txtANDRELUBECK.pdf.txtExtracted texttext/plain279765http://repositorio.ufsm.br/bitstream/1/7691/2/ANDRELUBECK.pdf.txtcb6ea0235291f1c9a0e61be57a24f2bcMD52THUMBNAILANDRELUBECK.pdf.jpgANDRELUBECK.pdf.jpgIM Thumbnailimage/jpeg5466http://repositorio.ufsm.br/bitstream/1/7691/3/ANDRELUBECK.pdf.jpg038bac337e9c9a4e928e4215bc721f7fMD531/76912021-09-28 19:12:55.615oai:repositorio.ufsm.br:1/7691Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/ONGhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.comopendoar:2021-09-28T22:12:55Biblioteca Digital de Teses e Dissertações do UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.por.fl_str_mv Resistividade elétrica de concretos de cimento Portland branco e elevados teores de escória de alto forno
dc.title.alternative.eng.fl_str_mv Electrical resistivity of white Portland cement concretes and high blast furnace slag content
title Resistividade elétrica de concretos de cimento Portland branco e elevados teores de escória de alto forno
spellingShingle Resistividade elétrica de concretos de cimento Portland branco e elevados teores de escória de alto forno
Lübeck, André
Concreto
Resistividade elétrica
Cimento Portland branco
Escória de alto forno
Concrete
Electrical resistivity
White Portland cement
Blast furnace slag
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
title_short Resistividade elétrica de concretos de cimento Portland branco e elevados teores de escória de alto forno
title_full Resistividade elétrica de concretos de cimento Portland branco e elevados teores de escória de alto forno
title_fullStr Resistividade elétrica de concretos de cimento Portland branco e elevados teores de escória de alto forno
title_full_unstemmed Resistividade elétrica de concretos de cimento Portland branco e elevados teores de escória de alto forno
title_sort Resistividade elétrica de concretos de cimento Portland branco e elevados teores de escória de alto forno
author Lübeck, André
author_facet Lübeck, André
author_role author
dc.contributor.advisor1.fl_str_mv Gastaldini, Antonio Luiz Guerra
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/9293085240832049
dc.contributor.referee1.fl_str_mv Cervo, Tatiana Cureau
dc.contributor.referee1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4767432H6
dc.contributor.referee2.fl_str_mv Kazmierczak, Claudio de Souza
dc.contributor.referee2Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4787715T4
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/7511022637484145
dc.contributor.author.fl_str_mv Lübeck, André
contributor_str_mv Gastaldini, Antonio Luiz Guerra
Cervo, Tatiana Cureau
Kazmierczak, Claudio de Souza
dc.subject.por.fl_str_mv Concreto
Resistividade elétrica
Cimento Portland branco
Escória de alto forno
topic Concreto
Resistividade elétrica
Cimento Portland branco
Escória de alto forno
Concrete
Electrical resistivity
White Portland cement
Blast furnace slag
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
dc.subject.eng.fl_str_mv Concrete
Electrical resistivity
White Portland cement
Blast furnace slag
dc.subject.cnpq.fl_str_mv CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
description The electrical resistivity is an important concrete property that allows evaluating the access facility of aggressive agents before the corrosion process begins and estimates the velocity of the same process after it begun. The electrical resistivity and the oxygen availability are the characteristics that control the corrosion velocity. This work aimed to evaluate the performance of white Portland cement concretes with high blast furnace slag content and chemical activation on the electrical resistivity. Other properties were measured, as axial compressive strength, porosity and specific electrical conductivity of pore solution. Four mixtures were tested, a reference one, only with white Portland cement as binder, a second one, with 50% of blast furnace slag in substitution of cement, other with 70% slag content, and the last one, with 50% of slag and alkaline activation, 4% of Na2SO4. The water/binder ratios were fixed at 0,30, 0,42 and 0,55 for all samples. The electrical resistivity was measured using the four electrode method (Wenner method). The sample age, water/binder ratio and the slag content have an expressive effect over the electrical resistivity, especially because it results in changes of the pore structure. The electrical resistivity grows as the amount of slag increases. The increase of slag amount also results in smaller specific electrical conductivity of pore solution and pore structure refinement. On the other hand, the axial compressive strength decreases as the slag amount increases. The biggest resistivity results were obtained for the mixture with 70% of slag. This mixture showed the best cost/benefit ratio as compressive strength were fixed at 35 and 55 MPa, at 28 days, and 60 MPa, at 91 days.
publishDate 2008
dc.date.accessioned.fl_str_mv 2008-06-16
dc.date.available.fl_str_mv 2008-06-16
dc.date.issued.fl_str_mv 2008-03-03
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv LÜBECK, André. ELECTRICAL RESISTIVITY OF WHITE PORTLAND CEMENT CONCRETES AND HIGH BLAST FURNACE SLAG CONTENT. 2008. 142 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Santa Maria, Santa Maria, 2008.
dc.identifier.uri.fl_str_mv http://repositorio.ufsm.br/handle/1/7691
identifier_str_mv LÜBECK, André. ELECTRICAL RESISTIVITY OF WHITE PORTLAND CEMENT CONCRETES AND HIGH BLAST FURNACE SLAG CONTENT. 2008. 142 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Santa Maria, Santa Maria, 2008.
url http://repositorio.ufsm.br/handle/1/7691
dc.language.iso.fl_str_mv por
language por
dc.relation.cnpq.fl_str_mv 300100000003
dc.relation.confidence.fl_str_mv 400
300
300
300
300
dc.relation.authority.fl_str_mv 6a6bd4d6-e9f2-46f6-9245-5aefb19c7a28
bb3198fe-a0ee-4ce7-92c7-b9a63722dce8
05e1fbb9-96a8-4d37-a468-44e3ad60f72f
15e1730c-aa0f-48ec-964e-73c3c2d36f6c
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Engenharia Civil
dc.publisher.initials.fl_str_mv UFSM
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Engenharia Civil
publisher.none.fl_str_mv Universidade Federal de Santa Maria
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações do UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Biblioteca Digital de Teses e Dissertações do UFSM
collection Biblioteca Digital de Teses e Dissertações do UFSM
bitstream.url.fl_str_mv http://repositorio.ufsm.br/bitstream/1/7691/1/ANDRELUBECK.pdf
http://repositorio.ufsm.br/bitstream/1/7691/2/ANDRELUBECK.pdf.txt
http://repositorio.ufsm.br/bitstream/1/7691/3/ANDRELUBECK.pdf.jpg
bitstream.checksum.fl_str_mv a5425fd4f3ffc27d3c84d7f8af88afe7
cb6ea0235291f1c9a0e61be57a24f2bc
038bac337e9c9a4e928e4215bc721f7f
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações do UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv atendimento.sib@ufsm.br||tedebc@gmail.com
_version_ 1801485204420820992