The impact of tibial torsion measurements on gait analysis kinematics

Detalhes bibliográficos
Autor(a) principal: Lucareli, Paulo Roberto Garcia
Data de Publicação: 2014
Outros Autores: Santos, Nadia Maria, Godoy, Wagner De, Bernal, Milena Moreira Barreto, Paes, Ângela Tavares, Ramalho Junior, Amancio
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/1413-78522014220500579
http://repositorio.unifesp.br/handle/11600/8626
Resumo: Objective:To measure and compare tibial torsion values as assessed by goniometry and three-dimensional kinematics. In addition, the impact of each one of these measurements on kinematic and kinetic results for normal gait was determined.Methods:Twenty-three healthy and fully ambulatory patients were assessed, 11 women and 12 men, from 20 to 40 years old. Data were collected at a laboratory for the three-dimensional analysis of movement with 10 cameras and two force plates. Tibial torsion measurements were obtained using goniometry and three-dimensional kinematics based on the Plug-in Gait model. Afterwards, both procedures were compared, and the impact of each result was assessed on the kinematic and kinetic modeling of the knee and ankle.Results:Pearson's linear correlation coefficient (r=0,504) showed a moderate correlation between the three-dimensional kinematics and goniometry, and between the changes in the measurements. Regarding the processed kinematic and kinetic results for every torsion position, no significant differences were noticed among any of the studied variables (p>0.05).Conclusion:Although statistical correlation among tibial torsion angles by goniometry and three-dimensional kinematic were moderate, kinematic and kinetic analysis of the joints did not reveal any significant changes. Level of Evidence I, Diagnostic Studies - Investigating a Diagnostic Test.
id UFSP_0d534fadf02615379e73520d917233fc
oai_identifier_str oai:repositorio.unifesp.br/:11600/8626
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling The impact of tibial torsion measurements on gait analysis kinematicsTibiaTorsion abnormalityBiomechanical phenomenaObjective:To measure and compare tibial torsion values as assessed by goniometry and three-dimensional kinematics. In addition, the impact of each one of these measurements on kinematic and kinetic results for normal gait was determined.Methods:Twenty-three healthy and fully ambulatory patients were assessed, 11 women and 12 men, from 20 to 40 years old. Data were collected at a laboratory for the three-dimensional analysis of movement with 10 cameras and two force plates. Tibial torsion measurements were obtained using goniometry and three-dimensional kinematics based on the Plug-in Gait model. Afterwards, both procedures were compared, and the impact of each result was assessed on the kinematic and kinetic modeling of the knee and ankle.Results:Pearson's linear correlation coefficient (r=0,504) showed a moderate correlation between the three-dimensional kinematics and goniometry, and between the changes in the measurements. Regarding the processed kinematic and kinetic results for every torsion position, no significant differences were noticed among any of the studied variables (p>0.05).Conclusion:Although statistical correlation among tibial torsion angles by goniometry and three-dimensional kinematic were moderate, kinematic and kinetic analysis of the joints did not reveal any significant changes. Level of Evidence I, Diagnostic Studies - Investigating a Diagnostic Test.Universidade Nove de JulhoUniversidade de São PauloHospital Israelita Albert EinsteinUniversidade Federal de São Paulo (UNIFESP)UNIFESP, EPM, São PauloSciELOSociedade Brasileira de Ortopedia e TraumatologiaUniversidade Nove de JulhoUniversidade de São Paulo (USP)Hospital Israelita Albert EinsteinUniversidade Federal de São Paulo (UNIFESP)Lucareli, Paulo Roberto GarciaSantos, Nadia MariaGodoy, Wagner DeBernal, Milena Moreira BarretoPaes, Ângela TavaresRamalho Junior, Amancio2015-06-14T13:47:20Z2015-06-14T13:47:20Z2014-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion278-282application/pdfhttp://dx.doi.org/10.1590/1413-78522014220500579Acta Ortopédica Brasileira. Sociedade Brasileira de Ortopedia e Traumatologia, v. 22, n. 5, p. 278-282, 2014.10.1590/1413-78522014220500579S1413-78522014000500278.pdf1413-7852S1413-78522014000500278http://repositorio.unifesp.br/handle/11600/8626engActa Ortopédica Brasileirainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-05T08:37:14Zoai:repositorio.unifesp.br/:11600/8626Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-05T08:37:14Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv The impact of tibial torsion measurements on gait analysis kinematics
title The impact of tibial torsion measurements on gait analysis kinematics
spellingShingle The impact of tibial torsion measurements on gait analysis kinematics
Lucareli, Paulo Roberto Garcia
Tibia
Torsion abnormality
Biomechanical phenomena
title_short The impact of tibial torsion measurements on gait analysis kinematics
title_full The impact of tibial torsion measurements on gait analysis kinematics
title_fullStr The impact of tibial torsion measurements on gait analysis kinematics
title_full_unstemmed The impact of tibial torsion measurements on gait analysis kinematics
title_sort The impact of tibial torsion measurements on gait analysis kinematics
author Lucareli, Paulo Roberto Garcia
author_facet Lucareli, Paulo Roberto Garcia
Santos, Nadia Maria
Godoy, Wagner De
Bernal, Milena Moreira Barreto
Paes, Ângela Tavares
Ramalho Junior, Amancio
author_role author
author2 Santos, Nadia Maria
Godoy, Wagner De
Bernal, Milena Moreira Barreto
Paes, Ângela Tavares
Ramalho Junior, Amancio
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Nove de Julho
Universidade de São Paulo (USP)
Hospital Israelita Albert Einstein
Universidade Federal de São Paulo (UNIFESP)
dc.contributor.author.fl_str_mv Lucareli, Paulo Roberto Garcia
Santos, Nadia Maria
Godoy, Wagner De
Bernal, Milena Moreira Barreto
Paes, Ângela Tavares
Ramalho Junior, Amancio
dc.subject.por.fl_str_mv Tibia
Torsion abnormality
Biomechanical phenomena
topic Tibia
Torsion abnormality
Biomechanical phenomena
description Objective:To measure and compare tibial torsion values as assessed by goniometry and three-dimensional kinematics. In addition, the impact of each one of these measurements on kinematic and kinetic results for normal gait was determined.Methods:Twenty-three healthy and fully ambulatory patients were assessed, 11 women and 12 men, from 20 to 40 years old. Data were collected at a laboratory for the three-dimensional analysis of movement with 10 cameras and two force plates. Tibial torsion measurements were obtained using goniometry and three-dimensional kinematics based on the Plug-in Gait model. Afterwards, both procedures were compared, and the impact of each result was assessed on the kinematic and kinetic modeling of the knee and ankle.Results:Pearson's linear correlation coefficient (r=0,504) showed a moderate correlation between the three-dimensional kinematics and goniometry, and between the changes in the measurements. Regarding the processed kinematic and kinetic results for every torsion position, no significant differences were noticed among any of the studied variables (p>0.05).Conclusion:Although statistical correlation among tibial torsion angles by goniometry and three-dimensional kinematic were moderate, kinematic and kinetic analysis of the joints did not reveal any significant changes. Level of Evidence I, Diagnostic Studies - Investigating a Diagnostic Test.
publishDate 2014
dc.date.none.fl_str_mv 2014-10-01
2015-06-14T13:47:20Z
2015-06-14T13:47:20Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/1413-78522014220500579
Acta Ortopédica Brasileira. Sociedade Brasileira de Ortopedia e Traumatologia, v. 22, n. 5, p. 278-282, 2014.
10.1590/1413-78522014220500579
S1413-78522014000500278.pdf
1413-7852
S1413-78522014000500278
http://repositorio.unifesp.br/handle/11600/8626
url http://dx.doi.org/10.1590/1413-78522014220500579
http://repositorio.unifesp.br/handle/11600/8626
identifier_str_mv Acta Ortopédica Brasileira. Sociedade Brasileira de Ortopedia e Traumatologia, v. 22, n. 5, p. 278-282, 2014.
10.1590/1413-78522014220500579
S1413-78522014000500278.pdf
1413-7852
S1413-78522014000500278
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Acta Ortopédica Brasileira
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 278-282
application/pdf
dc.publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268304327442432