Análise de nova técnica para o implante do anel de Ferrara no ceratocone
Autor(a) principal: | |
---|---|
Data de Publicação: | 2004 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Institucional da UNIFESP |
dARK ID: | ark:/48912/001300000t90z |
DOI: | 10.1590/S0004-27492004000300024 |
Texto Completo: | http://dx.doi.org/10.1590/S0004-27492004000300024 http://repositorio.unifesp.br/handle/11600/2130 |
Resumo: | PURPOSE: To describe a new surgical technique for Ferrara ring implantation and to evaluate its safety and efficacy in keratoconus patients. METHODS: A new technique was developed for implanting the Ferrara ring through a single corneal incision. A prospective study of twenty keratoconus patients operated on with this new technique was performed. The exclusion criteria included good contact lens tolerance, presence of significant corneal scar, presence of other ocular or systemic diseases, pachymetry lower than 400 micrometers and keratometry limits higher than 65D. LogMAR visual acuity and keratometry were analyzed both pre- and postoperatively. All complications and complaints during and after surgery were registered. The minimum follow-up period was twelve months. RESULTS: The mean uncorrected visual acuity improved from 1.045 ± 0.478 (preop) to 0.586 ± 0.373 LogMAR units after a twelve month follow-up. The mean corrected visual acuity improved from 0.714 ± 0.542 (preop) to 0.264 ± 0.162 LogMAR units (p=0.001) twelve months after surgery. The mean keratometric values varied from 55.9D ± 4.4D to 51.5D ± 4.8D in the follow-up period (p<0.0001). Three months after surgery, all patients had stable visual acuity. There were no per- or postoperative complications. CONCLUSIONS: This study showed that it is possible to implant the Ferrara ring through a single incision. This new surgical technique showed significant improvement in both corrected and uncorrected visual acuity and showed corneal flattening twelve months after surgery. No complications or complaints were observed. |
id |
UFSP_4079bab3b98dd5391082d64489df64eb |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/2130 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Análise de nova técnica para o implante do anel de Ferrara no ceratoconeAnalysis of new technique for Ferrara ring implantation in keratoconusKeratoconusOphthalmic surgical proceduresProstheses and implantsEfficacySafetyQuality of controlCeratoconeProcedimentos cirúrgicos oftalmológicosPróteses e implantesEficáciaSegurançaControle de qualidadePURPOSE: To describe a new surgical technique for Ferrara ring implantation and to evaluate its safety and efficacy in keratoconus patients. METHODS: A new technique was developed for implanting the Ferrara ring through a single corneal incision. A prospective study of twenty keratoconus patients operated on with this new technique was performed. The exclusion criteria included good contact lens tolerance, presence of significant corneal scar, presence of other ocular or systemic diseases, pachymetry lower than 400 micrometers and keratometry limits higher than 65D. LogMAR visual acuity and keratometry were analyzed both pre- and postoperatively. All complications and complaints during and after surgery were registered. The minimum follow-up period was twelve months. RESULTS: The mean uncorrected visual acuity improved from 1.045 ± 0.478 (preop) to 0.586 ± 0.373 LogMAR units after a twelve month follow-up. The mean corrected visual acuity improved from 0.714 ± 0.542 (preop) to 0.264 ± 0.162 LogMAR units (p=0.001) twelve months after surgery. The mean keratometric values varied from 55.9D ± 4.4D to 51.5D ± 4.8D in the follow-up period (p<0.0001). Three months after surgery, all patients had stable visual acuity. There were no per- or postoperative complications. CONCLUSIONS: This study showed that it is possible to implant the Ferrara ring through a single incision. This new surgical technique showed significant improvement in both corrected and uncorrected visual acuity and showed corneal flattening twelve months after surgery. No complications or complaints were observed.OBJETIVO: Descrever nova técnica para o implante do anel de Ferrara por meio de incisão única e avaliar segurança e eficácia em pacientes com ceratocone. MÉTODOS: Estudo prospectivo em vinte pacientes com ceratocone, submetidos ao implante por meio desta nova técnica. Critérios de exclusão: boa adaptação a lentes de contato, presença de cicatrizes corneanas significativas, ápice do cone com mais de 65 dioptrias, paquimetria inferior a 400 micra no local da incisão e presença de doenças oculares ou sistêmicas que contra-indicassem a cirurgia. Acuidade visual (LogMAR) e medida do ápice corneano pela topografia foram as variáveis analisadas no pré e pós-operatório. Foram registradas possíveis complicações ou queixas relacionadas às cirurgias. Período mínimo de um ano de acompanhamento. RESULTADOS: A acuidade visual média não corrigida melhorou de 1,045 ± 0,478 (mediana de 1,150) no pré-operatório, para 0,586 ± 0,373 (mediana de 0,500) unidades LogMAR, após doze meses de pós-operatório (p<0,0001). A acuidade visual com correção melhorou de 0,714 ± 0,542 (mediana de 0,500) para 0,264 ± 0,162 (mediana de 0,200) unidades LogMAR (p=0,001). A média do ápice corneano pela topografia variou de 55,9 ± 4,4D no pré-operatório, para 51,5 ± 4,8D após doze meses de pós-operatório (p<0,0001). Após o terceiro mês de cirurgia, todos os pacientes evoluíram com estabilização da acuidade visual. Não houve complicações ou queixas durante o período estudado. CONCLUSÃO: O implante do anel de Ferrara, por meio de incisão única, determinou melhora da acuidade visual, sem correção e com correção, e aplanamento corneano significativos no grupo estudado, após doze meses de cirurgia.Instituto de Pesquisas MédicasUniversidade Federal de São Paulo (UNIFESP)Universidade Federal do ParanáFaculdade Evangélica do ParanáHospital de Olhos do ParanáUNIFESPSciELOConselho Brasileiro de OftalmologiaInstituto de Pesquisas MédicasUniversidade Federal de São Paulo (UNIFESP)Universidade Federal do ParanáFaculdade Evangélica do ParanáHospital de Olhos do ParanáOliveira, Cinara Sakuma DeMoreira, Hamilton [UNIFESP]Wahab, Sâmia AliGodoy, Glaucio De2015-06-14T13:31:10Z2015-06-14T13:31:10Z2004-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion509-517application/pdfhttp://dx.doi.org/10.1590/S0004-27492004000300024Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 67, n. 3, p. 509-517, 2004.10.1590/S0004-27492004000300024S0004-27492004000300024.pdf0004-2749S0004-27492004000300024http://repositorio.unifesp.br/handle/11600/2130ark:/48912/001300000t90zporArquivos Brasileiros de Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-07-28T07:24:44Zoai:repositorio.unifesp.br/:11600/2130Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-12-11T20:37:04.916773Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Análise de nova técnica para o implante do anel de Ferrara no ceratocone Analysis of new technique for Ferrara ring implantation in keratoconus |
title |
Análise de nova técnica para o implante do anel de Ferrara no ceratocone |
spellingShingle |
Análise de nova técnica para o implante do anel de Ferrara no ceratocone Análise de nova técnica para o implante do anel de Ferrara no ceratocone Oliveira, Cinara Sakuma De Keratoconus Ophthalmic surgical procedures Prostheses and implants Efficacy Safety Quality of control Ceratocone Procedimentos cirúrgicos oftalmológicos Próteses e implantes Eficácia Segurança Controle de qualidade Oliveira, Cinara Sakuma De Keratoconus Ophthalmic surgical procedures Prostheses and implants Efficacy Safety Quality of control Ceratocone Procedimentos cirúrgicos oftalmológicos Próteses e implantes Eficácia Segurança Controle de qualidade |
title_short |
Análise de nova técnica para o implante do anel de Ferrara no ceratocone |
title_full |
Análise de nova técnica para o implante do anel de Ferrara no ceratocone |
title_fullStr |
Análise de nova técnica para o implante do anel de Ferrara no ceratocone Análise de nova técnica para o implante do anel de Ferrara no ceratocone |
title_full_unstemmed |
Análise de nova técnica para o implante do anel de Ferrara no ceratocone Análise de nova técnica para o implante do anel de Ferrara no ceratocone |
title_sort |
Análise de nova técnica para o implante do anel de Ferrara no ceratocone |
author |
Oliveira, Cinara Sakuma De |
author_facet |
Oliveira, Cinara Sakuma De Oliveira, Cinara Sakuma De Moreira, Hamilton [UNIFESP] Wahab, Sâmia Ali Godoy, Glaucio De Moreira, Hamilton [UNIFESP] Wahab, Sâmia Ali Godoy, Glaucio De |
author_role |
author |
author2 |
Moreira, Hamilton [UNIFESP] Wahab, Sâmia Ali Godoy, Glaucio De |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Instituto de Pesquisas Médicas Universidade Federal de São Paulo (UNIFESP) Universidade Federal do Paraná Faculdade Evangélica do Paraná Hospital de Olhos do Paraná |
dc.contributor.author.fl_str_mv |
Oliveira, Cinara Sakuma De Moreira, Hamilton [UNIFESP] Wahab, Sâmia Ali Godoy, Glaucio De |
dc.subject.por.fl_str_mv |
Keratoconus Ophthalmic surgical procedures Prostheses and implants Efficacy Safety Quality of control Ceratocone Procedimentos cirúrgicos oftalmológicos Próteses e implantes Eficácia Segurança Controle de qualidade |
topic |
Keratoconus Ophthalmic surgical procedures Prostheses and implants Efficacy Safety Quality of control Ceratocone Procedimentos cirúrgicos oftalmológicos Próteses e implantes Eficácia Segurança Controle de qualidade |
description |
PURPOSE: To describe a new surgical technique for Ferrara ring implantation and to evaluate its safety and efficacy in keratoconus patients. METHODS: A new technique was developed for implanting the Ferrara ring through a single corneal incision. A prospective study of twenty keratoconus patients operated on with this new technique was performed. The exclusion criteria included good contact lens tolerance, presence of significant corneal scar, presence of other ocular or systemic diseases, pachymetry lower than 400 micrometers and keratometry limits higher than 65D. LogMAR visual acuity and keratometry were analyzed both pre- and postoperatively. All complications and complaints during and after surgery were registered. The minimum follow-up period was twelve months. RESULTS: The mean uncorrected visual acuity improved from 1.045 ± 0.478 (preop) to 0.586 ± 0.373 LogMAR units after a twelve month follow-up. The mean corrected visual acuity improved from 0.714 ± 0.542 (preop) to 0.264 ± 0.162 LogMAR units (p=0.001) twelve months after surgery. The mean keratometric values varied from 55.9D ± 4.4D to 51.5D ± 4.8D in the follow-up period (p<0.0001). Three months after surgery, all patients had stable visual acuity. There were no per- or postoperative complications. CONCLUSIONS: This study showed that it is possible to implant the Ferrara ring through a single incision. This new surgical technique showed significant improvement in both corrected and uncorrected visual acuity and showed corneal flattening twelve months after surgery. No complications or complaints were observed. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004-06-01 2015-06-14T13:31:10Z 2015-06-14T13:31:10Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/S0004-27492004000300024 Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 67, n. 3, p. 509-517, 2004. 10.1590/S0004-27492004000300024 S0004-27492004000300024.pdf 0004-2749 S0004-27492004000300024 http://repositorio.unifesp.br/handle/11600/2130 |
dc.identifier.dark.fl_str_mv |
ark:/48912/001300000t90z |
url |
http://dx.doi.org/10.1590/S0004-27492004000300024 http://repositorio.unifesp.br/handle/11600/2130 |
identifier_str_mv |
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 67, n. 3, p. 509-517, 2004. 10.1590/S0004-27492004000300024 S0004-27492004000300024.pdf 0004-2749 S0004-27492004000300024 ark:/48912/001300000t90z |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
509-517 application/pdf |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1822183974886178816 |
dc.identifier.doi.none.fl_str_mv |
10.1590/S0004-27492004000300024 |