Detection of adrenocortical autoantibodies in Addison's disease with a peroxidase-labelled protein A technique

Detalhes bibliográficos
Autor(a) principal: Silva, Reinaldo Correia [UNIFESP]
Data de Publicação: 1998
Outros Autores: Faiçal, Samir [UNIFESP], Laureti, Stefano, Falorni, Alberto, Dib, Sergio Atala [UNIFESP], Kater, Claudio Elias [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S0100-879X1998000900007
http://repositorio.unifesp.br/handle/11600/674
Resumo: Adrenocortical autoantibodies (ACA), present in 60-80% of patients with idiopathic Addison's disease, are conventionally detected by indirect immunofluorescence (IIF) on frozen sections of adrenal glands. The large-scale use of IIF is limited in part by the need for a fluorescence microscope and the fact that histological sections cannot be stored for long periods of time. To circumvent these restrictions we developed a novel peroxidase-labelled protein A (PLPA) technique for the detection of ACA in patients with Addison's disease and compared the results with those obtained with the classical IIF assay. We studied serum samples from 90 healthy control subjects and 22 patients with Addison's disease, who had been clinically classified into two groups: idiopathic (N = 13) and granulomatous (N = 9). ACA-PLPA were detected in 10/22 (45%) patients: 9/13 (69%) with the idiopathic form and 1/9 (11%) with the granulomatous form, whereas ACA-IIF were detected in 11/22 patients (50%): 10/13 (77%) with the idiopathic form and 1/9 (11%) with the granulomatous form. Twelve of the 13 idiopathic addisonians (92%) were positive for either ACA-PLPA or ACA-IIF, but only 7 were positive by both methods. In contrast, none of 90 healthy subjects was found to be positive for ACA. Thus, our study shows that the PLPA-based technique is useful, has technical advantages over the IIF method (by not requiring the use of a fluorescence microscope and by permitting section storage for long periods of time). However, since it is only 60% concordant with the ACA-IIF method, it should be considered complementary instead of an alternative method to IIF for the detection of ACA in human sera.
id UFSP_4267aeb170311c108bafe790220ed20e
oai_identifier_str oai:repositorio.unifesp.br/:11600/674
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Detection of adrenocortical autoantibodies in Addison's disease with a peroxidase-labelled protein A techniqueautoantibodies detectionAddison's diseaseperoxidase-labelled protein Aindirect immunofluorescenceadrenal glandAdrenocortical autoantibodies (ACA), present in 60-80% of patients with idiopathic Addison's disease, are conventionally detected by indirect immunofluorescence (IIF) on frozen sections of adrenal glands. The large-scale use of IIF is limited in part by the need for a fluorescence microscope and the fact that histological sections cannot be stored for long periods of time. To circumvent these restrictions we developed a novel peroxidase-labelled protein A (PLPA) technique for the detection of ACA in patients with Addison's disease and compared the results with those obtained with the classical IIF assay. We studied serum samples from 90 healthy control subjects and 22 patients with Addison's disease, who had been clinically classified into two groups: idiopathic (N = 13) and granulomatous (N = 9). ACA-PLPA were detected in 10/22 (45%) patients: 9/13 (69%) with the idiopathic form and 1/9 (11%) with the granulomatous form, whereas ACA-IIF were detected in 11/22 patients (50%): 10/13 (77%) with the idiopathic form and 1/9 (11%) with the granulomatous form. Twelve of the 13 idiopathic addisonians (92%) were positive for either ACA-PLPA or ACA-IIF, but only 7 were positive by both methods. In contrast, none of 90 healthy subjects was found to be positive for ACA. Thus, our study shows that the PLPA-based technique is useful, has technical advantages over the IIF method (by not requiring the use of a fluorescence microscope and by permitting section storage for long periods of time). However, since it is only 60% concordant with the ACA-IIF method, it should be considered complementary instead of an alternative method to IIF for the detection of ACA in human sera.Universidade Federal de São Paulo (UNIFESP)University of PerugiaUNIFESPSciELOAssociação Brasileira de Divulgação CientíficaUniversidade Federal de São Paulo (UNIFESP)University of PerugiaSilva, Reinaldo Correia [UNIFESP]Faiçal, Samir [UNIFESP]Laureti, StefanoFalorni, AlbertoDib, Sergio Atala [UNIFESP]Kater, Claudio Elias [UNIFESP]2015-06-14T13:24:46Z2015-06-14T13:24:46Z1998-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion1141-1148application/pdfhttp://dx.doi.org/10.1590/S0100-879X1998000900007Brazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 31, n. 9, p. 1141-1148, 1998.10.1590/S0100-879X1998000900007S0100-879X1998000900007.pdf0100-879XS0100-879X1998000900007http://repositorio.unifesp.br/handle/11600/674WOS:000076297100007engBrazilian Journal of Medical and Biological Researchinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-07-29T16:58:59Zoai:repositorio.unifesp.br/:11600/674Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-07-29T16:58:59Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Detection of adrenocortical autoantibodies in Addison's disease with a peroxidase-labelled protein A technique
title Detection of adrenocortical autoantibodies in Addison's disease with a peroxidase-labelled protein A technique
spellingShingle Detection of adrenocortical autoantibodies in Addison's disease with a peroxidase-labelled protein A technique
Silva, Reinaldo Correia [UNIFESP]
autoantibodies detection
Addison's disease
peroxidase-labelled protein A
indirect immunofluorescence
adrenal gland
title_short Detection of adrenocortical autoantibodies in Addison's disease with a peroxidase-labelled protein A technique
title_full Detection of adrenocortical autoantibodies in Addison's disease with a peroxidase-labelled protein A technique
title_fullStr Detection of adrenocortical autoantibodies in Addison's disease with a peroxidase-labelled protein A technique
title_full_unstemmed Detection of adrenocortical autoantibodies in Addison's disease with a peroxidase-labelled protein A technique
title_sort Detection of adrenocortical autoantibodies in Addison's disease with a peroxidase-labelled protein A technique
author Silva, Reinaldo Correia [UNIFESP]
author_facet Silva, Reinaldo Correia [UNIFESP]
Faiçal, Samir [UNIFESP]
Laureti, Stefano
Falorni, Alberto
Dib, Sergio Atala [UNIFESP]
Kater, Claudio Elias [UNIFESP]
author_role author
author2 Faiçal, Samir [UNIFESP]
Laureti, Stefano
Falorni, Alberto
Dib, Sergio Atala [UNIFESP]
Kater, Claudio Elias [UNIFESP]
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
University of Perugia
dc.contributor.author.fl_str_mv Silva, Reinaldo Correia [UNIFESP]
Faiçal, Samir [UNIFESP]
Laureti, Stefano
Falorni, Alberto
Dib, Sergio Atala [UNIFESP]
Kater, Claudio Elias [UNIFESP]
dc.subject.por.fl_str_mv autoantibodies detection
Addison's disease
peroxidase-labelled protein A
indirect immunofluorescence
adrenal gland
topic autoantibodies detection
Addison's disease
peroxidase-labelled protein A
indirect immunofluorescence
adrenal gland
description Adrenocortical autoantibodies (ACA), present in 60-80% of patients with idiopathic Addison's disease, are conventionally detected by indirect immunofluorescence (IIF) on frozen sections of adrenal glands. The large-scale use of IIF is limited in part by the need for a fluorescence microscope and the fact that histological sections cannot be stored for long periods of time. To circumvent these restrictions we developed a novel peroxidase-labelled protein A (PLPA) technique for the detection of ACA in patients with Addison's disease and compared the results with those obtained with the classical IIF assay. We studied serum samples from 90 healthy control subjects and 22 patients with Addison's disease, who had been clinically classified into two groups: idiopathic (N = 13) and granulomatous (N = 9). ACA-PLPA were detected in 10/22 (45%) patients: 9/13 (69%) with the idiopathic form and 1/9 (11%) with the granulomatous form, whereas ACA-IIF were detected in 11/22 patients (50%): 10/13 (77%) with the idiopathic form and 1/9 (11%) with the granulomatous form. Twelve of the 13 idiopathic addisonians (92%) were positive for either ACA-PLPA or ACA-IIF, but only 7 were positive by both methods. In contrast, none of 90 healthy subjects was found to be positive for ACA. Thus, our study shows that the PLPA-based technique is useful, has technical advantages over the IIF method (by not requiring the use of a fluorescence microscope and by permitting section storage for long periods of time). However, since it is only 60% concordant with the ACA-IIF method, it should be considered complementary instead of an alternative method to IIF for the detection of ACA in human sera.
publishDate 1998
dc.date.none.fl_str_mv 1998-09-01
2015-06-14T13:24:46Z
2015-06-14T13:24:46Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0100-879X1998000900007
Brazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 31, n. 9, p. 1141-1148, 1998.
10.1590/S0100-879X1998000900007
S0100-879X1998000900007.pdf
0100-879X
S0100-879X1998000900007
http://repositorio.unifesp.br/handle/11600/674
WOS:000076297100007
url http://dx.doi.org/10.1590/S0100-879X1998000900007
http://repositorio.unifesp.br/handle/11600/674
identifier_str_mv Brazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 31, n. 9, p. 1141-1148, 1998.
10.1590/S0100-879X1998000900007
S0100-879X1998000900007.pdf
0100-879X
S0100-879X1998000900007
WOS:000076297100007
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Journal of Medical and Biological Research
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 1141-1148
application/pdf
dc.publisher.none.fl_str_mv Associação Brasileira de Divulgação Científica
publisher.none.fl_str_mv Associação Brasileira de Divulgação Científica
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268366010974208