Physiological Requirements to Perform the Glittre Activities of Daily Living Test by Subjects With Mild-to-Severe COPD

Detalhes bibliográficos
Autor(a) principal: Souza, Gerson F. [UNIFESP]
Data de Publicação: 2017
Outros Autores: Moreira, Graciane L. [UNIFESP], Tufanin, Andrea [UNIFESP], Gazzotti, Mariana R. [UNIFESP], Castro, Antonio A. [UNIFESP], Jardim, Jose R. [UNIFESP], Nascimento, Oliver A. [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.4187/respcare.05113
http://repositorio.unifesp.br/handle/11600/51482
Resumo: BACKGROUND: The Glittre activities of daily living (ADL) test is supposed to evaluate the functional capacity of COPD patients. The physiological requirements of the test and the time taken to perform it by COPD patients in different disease stages are not well known. The objective of this work was to compare the metabolic, ventilatory, and cardiac requirements and the time taken to carry out the Glittre ADL test by COPD subjects with mild, moderate, and severe disease. METHODS: Spirometry, Medical Research Council questionnaire, cardiopulmonary exercise test, and 2 Glittre ADL tests were evaluated in 62 COPD subjects. Oxygen uptake ((V)over dot(O2)), carbon dioxide production, pulmonary ventilation, breathing frequency, heart rate, S-pO2, and dyspnea were analyzed before and at the end of the tests. Maximum voluntary ventilation, Glittre peak (V)over dot(O2)/cardiopulmonary exercise test (CPET) peak (V)over dot(O2), Glittre (V)over dot(E)/maximum voluntary ventilation, and Glittre peak heart rate/CPET peak heart rate ratios were calculated to analyze their reserves. RESULTS: Subjects carried out the Glittre ADL test with similar absolute metabolic, ventilatory, and cardiac requirements. Ventilatory reserve decreased progressively from mild to severe COPD subjects (P < .001 for Global Initiative for Chronic Obstructive Lung Disease [GOLD] 1 vs GOLD 2, P < .001 for GOLD 1 vs GOLD 3, and P < .001 for GOLD 2 vs GOLD 3). Severe subjects with COPD presented a significantly lower metabolic reserve than the mild and moderate subjects (P = .006 and P = .043, respectively) and significantly lower Glittre peak heart rate/CPET peak heart rate than mild subjects (P = .01). Time taken to carry out the Glittre ADL test was similar among the groups (P = .82 for GOLD 1 vs GOLD 2, P = .19 for GOLD 1 vs GOLD 3, and P = .45 for GOLD 2 vs GOLD 3). CONCLUSIONS: As the degree of air-flow obstruction progresses, the COPD subjects present significant lower ventilatory reserve to perform the Glittre ADL test. In addition, metabolic and cardiac reserves may differentiate the severe subjects. These variables may be better measures to differentiate functional performance than Glittre ADL time.
id UFSP_4f636fea6f799384609c31b0b8633e48
oai_identifier_str oai:repositorio.unifesp.br/:11600/51482
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Physiological Requirements to Perform the Glittre Activities of Daily Living Test by Subjects With Mild-to-Severe COPDactivity of daily livingCOPDexercise testfunctional capacityoutcome assessmentdisability evaluationBACKGROUND: The Glittre activities of daily living (ADL) test is supposed to evaluate the functional capacity of COPD patients. The physiological requirements of the test and the time taken to perform it by COPD patients in different disease stages are not well known. The objective of this work was to compare the metabolic, ventilatory, and cardiac requirements and the time taken to carry out the Glittre ADL test by COPD subjects with mild, moderate, and severe disease. METHODS: Spirometry, Medical Research Council questionnaire, cardiopulmonary exercise test, and 2 Glittre ADL tests were evaluated in 62 COPD subjects. Oxygen uptake ((V)over dot(O2)), carbon dioxide production, pulmonary ventilation, breathing frequency, heart rate, S-pO2, and dyspnea were analyzed before and at the end of the tests. Maximum voluntary ventilation, Glittre peak (V)over dot(O2)/cardiopulmonary exercise test (CPET) peak (V)over dot(O2), Glittre (V)over dot(E)/maximum voluntary ventilation, and Glittre peak heart rate/CPET peak heart rate ratios were calculated to analyze their reserves. RESULTS: Subjects carried out the Glittre ADL test with similar absolute metabolic, ventilatory, and cardiac requirements. Ventilatory reserve decreased progressively from mild to severe COPD subjects (P < .001 for Global Initiative for Chronic Obstructive Lung Disease [GOLD] 1 vs GOLD 2, P < .001 for GOLD 1 vs GOLD 3, and P < .001 for GOLD 2 vs GOLD 3). Severe subjects with COPD presented a significantly lower metabolic reserve than the mild and moderate subjects (P = .006 and P = .043, respectively) and significantly lower Glittre peak heart rate/CPET peak heart rate than mild subjects (P = .01). Time taken to carry out the Glittre ADL test was similar among the groups (P = .82 for GOLD 1 vs GOLD 2, P = .19 for GOLD 1 vs GOLD 3, and P = .45 for GOLD 2 vs GOLD 3). CONCLUSIONS: As the degree of air-flow obstruction progresses, the COPD subjects present significant lower ventilatory reserve to perform the Glittre ADL test. In addition, metabolic and cardiac reserves may differentiate the severe subjects. These variables may be better measures to differentiate functional performance than Glittre ADL time.Univ Fed São Paulo, Pulm Rehabil Ctr, São Paulo, BrazilFed Univ Pampa, Bage, RS, BrazilUniv Fed São Paulo, Pulm Rehabil Ctr, Resp Div, São Paulo, BrazilUniv Fed São Paulo, Pulm Rehabil Ctr, São Paulo, BrazilWeb of ScienceCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES, Brazil)Daedalus Enterprises Inc2019-08-19T11:50:09Z2019-08-19T11:50:09Z2017info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion1049-1057http://dx.doi.org/10.4187/respcare.05113Respiratory Care. Irving, v. 62, n. 8, p. 1049-1057, 2017.10.4187/respcare.051130020-1324http://repositorio.unifesp.br/handle/11600/51482WOS:000405994300007enginfo:eu-repo/semantics/openAccessSouza, Gerson F. [UNIFESP]Moreira, Graciane L. [UNIFESP]Tufanin, Andrea [UNIFESP]Gazzotti, Mariana R. [UNIFESP]Castro, Antonio A. [UNIFESP]Jardim, Jose R. [UNIFESP]Nascimento, Oliver A. [UNIFESP]reponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2019-08-19T08:50:09Zoai:repositorio.unifesp.br/:11600/51482Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652019-08-19T08:50:09Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Physiological Requirements to Perform the Glittre Activities of Daily Living Test by Subjects With Mild-to-Severe COPD
title Physiological Requirements to Perform the Glittre Activities of Daily Living Test by Subjects With Mild-to-Severe COPD
spellingShingle Physiological Requirements to Perform the Glittre Activities of Daily Living Test by Subjects With Mild-to-Severe COPD
Souza, Gerson F. [UNIFESP]
activity of daily living
COPD
exercise test
functional capacity
outcome assessment
disability evaluation
title_short Physiological Requirements to Perform the Glittre Activities of Daily Living Test by Subjects With Mild-to-Severe COPD
title_full Physiological Requirements to Perform the Glittre Activities of Daily Living Test by Subjects With Mild-to-Severe COPD
title_fullStr Physiological Requirements to Perform the Glittre Activities of Daily Living Test by Subjects With Mild-to-Severe COPD
title_full_unstemmed Physiological Requirements to Perform the Glittre Activities of Daily Living Test by Subjects With Mild-to-Severe COPD
title_sort Physiological Requirements to Perform the Glittre Activities of Daily Living Test by Subjects With Mild-to-Severe COPD
author Souza, Gerson F. [UNIFESP]
author_facet Souza, Gerson F. [UNIFESP]
Moreira, Graciane L. [UNIFESP]
Tufanin, Andrea [UNIFESP]
Gazzotti, Mariana R. [UNIFESP]
Castro, Antonio A. [UNIFESP]
Jardim, Jose R. [UNIFESP]
Nascimento, Oliver A. [UNIFESP]
author_role author
author2 Moreira, Graciane L. [UNIFESP]
Tufanin, Andrea [UNIFESP]
Gazzotti, Mariana R. [UNIFESP]
Castro, Antonio A. [UNIFESP]
Jardim, Jose R. [UNIFESP]
Nascimento, Oliver A. [UNIFESP]
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Souza, Gerson F. [UNIFESP]
Moreira, Graciane L. [UNIFESP]
Tufanin, Andrea [UNIFESP]
Gazzotti, Mariana R. [UNIFESP]
Castro, Antonio A. [UNIFESP]
Jardim, Jose R. [UNIFESP]
Nascimento, Oliver A. [UNIFESP]
dc.subject.por.fl_str_mv activity of daily living
COPD
exercise test
functional capacity
outcome assessment
disability evaluation
topic activity of daily living
COPD
exercise test
functional capacity
outcome assessment
disability evaluation
description BACKGROUND: The Glittre activities of daily living (ADL) test is supposed to evaluate the functional capacity of COPD patients. The physiological requirements of the test and the time taken to perform it by COPD patients in different disease stages are not well known. The objective of this work was to compare the metabolic, ventilatory, and cardiac requirements and the time taken to carry out the Glittre ADL test by COPD subjects with mild, moderate, and severe disease. METHODS: Spirometry, Medical Research Council questionnaire, cardiopulmonary exercise test, and 2 Glittre ADL tests were evaluated in 62 COPD subjects. Oxygen uptake ((V)over dot(O2)), carbon dioxide production, pulmonary ventilation, breathing frequency, heart rate, S-pO2, and dyspnea were analyzed before and at the end of the tests. Maximum voluntary ventilation, Glittre peak (V)over dot(O2)/cardiopulmonary exercise test (CPET) peak (V)over dot(O2), Glittre (V)over dot(E)/maximum voluntary ventilation, and Glittre peak heart rate/CPET peak heart rate ratios were calculated to analyze their reserves. RESULTS: Subjects carried out the Glittre ADL test with similar absolute metabolic, ventilatory, and cardiac requirements. Ventilatory reserve decreased progressively from mild to severe COPD subjects (P < .001 for Global Initiative for Chronic Obstructive Lung Disease [GOLD] 1 vs GOLD 2, P < .001 for GOLD 1 vs GOLD 3, and P < .001 for GOLD 2 vs GOLD 3). Severe subjects with COPD presented a significantly lower metabolic reserve than the mild and moderate subjects (P = .006 and P = .043, respectively) and significantly lower Glittre peak heart rate/CPET peak heart rate than mild subjects (P = .01). Time taken to carry out the Glittre ADL test was similar among the groups (P = .82 for GOLD 1 vs GOLD 2, P = .19 for GOLD 1 vs GOLD 3, and P = .45 for GOLD 2 vs GOLD 3). CONCLUSIONS: As the degree of air-flow obstruction progresses, the COPD subjects present significant lower ventilatory reserve to perform the Glittre ADL test. In addition, metabolic and cardiac reserves may differentiate the severe subjects. These variables may be better measures to differentiate functional performance than Glittre ADL time.
publishDate 2017
dc.date.none.fl_str_mv 2017
2019-08-19T11:50:09Z
2019-08-19T11:50:09Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.4187/respcare.05113
Respiratory Care. Irving, v. 62, n. 8, p. 1049-1057, 2017.
10.4187/respcare.05113
0020-1324
http://repositorio.unifesp.br/handle/11600/51482
WOS:000405994300007
url http://dx.doi.org/10.4187/respcare.05113
http://repositorio.unifesp.br/handle/11600/51482
identifier_str_mv Respiratory Care. Irving, v. 62, n. 8, p. 1049-1057, 2017.
10.4187/respcare.05113
0020-1324
WOS:000405994300007
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 1049-1057
dc.publisher.none.fl_str_mv Daedalus Enterprises Inc
publisher.none.fl_str_mv Daedalus Enterprises Inc
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268421608570880