Unplanned extubation in a paediatric intensive care unit: impact of a quality improvement programme
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNIFESP |
Texto Completo: | http://dx.doi.org/10.1111/j.1365-2044.2008.05628.x http://repositorio.unifesp.br/handle/11600/30982 |
Resumo: | Unplanned tracheal extubation is an important quality issue in current medical practice as it is a common occurrence ill paediatric intensive care units. We have assessed the effectiveness Ora continuous quality improvement programme in reducing the incidence of unplanned extubation Over a 5-year period. After a 2-year baseline period, we developed action plans to address the issues identified. Following implementation of the programme, the developed action plans to address the issues extubation decreased form 2.9 unplanned extubations per 100 intubated patient days in the first year to 0.6 in the last year (p = 0.0001). This reduction was the result of a decrease in unplanned extubation in children younger than 2 years of age. Although mortality was similar to that of Children who did not experience an unplanned extubation, those with an unplanned extubation had a significantly longer duration of mechanical ventilation, longer stay in the intensive care unit, and longer hospital stay. We found that the implementation of a continuous quality improvement programme is effective in reducing the overall incidence of unplanned extubations. |
id |
UFSP_54b090eaa01e691c2c240785f49a959c |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/30982 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Unplanned extubation in a paediatric intensive care unit: impact of a quality improvement programmeUnplanned tracheal extubation is an important quality issue in current medical practice as it is a common occurrence ill paediatric intensive care units. We have assessed the effectiveness Ora continuous quality improvement programme in reducing the incidence of unplanned extubation Over a 5-year period. After a 2-year baseline period, we developed action plans to address the issues identified. Following implementation of the programme, the developed action plans to address the issues extubation decreased form 2.9 unplanned extubations per 100 intubated patient days in the first year to 0.6 in the last year (p = 0.0001). This reduction was the result of a decrease in unplanned extubation in children younger than 2 years of age. Although mortality was similar to that of Children who did not experience an unplanned extubation, those with an unplanned extubation had a significantly longer duration of mechanical ventilation, longer stay in the intensive care unit, and longer hospital stay. We found that the implementation of a continuous quality improvement programme is effective in reducing the overall incidence of unplanned extubations.Hosp Estadual Diadema UNFESP, Paediat Intens Care Unit, Diadema, SP, BrazilUniversidade Federal de São Paulo, UNIFESP, Paediat Intens Care Unit, Dept Paediat, São Paulo, BrazilUniversidade Federal de São Paulo, UNIFESP, Paediat Intens Care Unit, Dept Paediat, São Paulo, BrazilWeb of ScienceWiley-BlackwellHosp Estadual Diadema UNFESPUniversidade Federal de São Paulo (UNIFESP)Silva, P. S. L. daAguiar, V. E. deNeto, H. M.Carvalho, W. B. de [UNIFESP]2016-01-24T13:51:47Z2016-01-24T13:51:47Z2008-11-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion1209-1216http://dx.doi.org/10.1111/j.1365-2044.2008.05628.xAnaesthesia. Malden: Wiley-Blackwell Publishing, Inc, v. 63, n. 11, p. 1209-1216, 2008.10.1111/j.1365-2044.2008.05628.x0003-2409http://repositorio.unifesp.br/handle/11600/30982WOS:000259937300009engAnaesthesiainfo:eu-repo/semantics/openAccesshttp://olabout.wiley.com/WileyCDA/Section/id-406071.htmlreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2022-02-07T21:01:45Zoai:repositorio.unifesp.br/:11600/30982Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652022-02-07T21:01:45Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Unplanned extubation in a paediatric intensive care unit: impact of a quality improvement programme |
title |
Unplanned extubation in a paediatric intensive care unit: impact of a quality improvement programme |
spellingShingle |
Unplanned extubation in a paediatric intensive care unit: impact of a quality improvement programme Silva, P. S. L. da |
title_short |
Unplanned extubation in a paediatric intensive care unit: impact of a quality improvement programme |
title_full |
Unplanned extubation in a paediatric intensive care unit: impact of a quality improvement programme |
title_fullStr |
Unplanned extubation in a paediatric intensive care unit: impact of a quality improvement programme |
title_full_unstemmed |
Unplanned extubation in a paediatric intensive care unit: impact of a quality improvement programme |
title_sort |
Unplanned extubation in a paediatric intensive care unit: impact of a quality improvement programme |
author |
Silva, P. S. L. da |
author_facet |
Silva, P. S. L. da Aguiar, V. E. de Neto, H. M. Carvalho, W. B. de [UNIFESP] |
author_role |
author |
author2 |
Aguiar, V. E. de Neto, H. M. Carvalho, W. B. de [UNIFESP] |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Hosp Estadual Diadema UNFESP Universidade Federal de São Paulo (UNIFESP) |
dc.contributor.author.fl_str_mv |
Silva, P. S. L. da Aguiar, V. E. de Neto, H. M. Carvalho, W. B. de [UNIFESP] |
description |
Unplanned tracheal extubation is an important quality issue in current medical practice as it is a common occurrence ill paediatric intensive care units. We have assessed the effectiveness Ora continuous quality improvement programme in reducing the incidence of unplanned extubation Over a 5-year period. After a 2-year baseline period, we developed action plans to address the issues identified. Following implementation of the programme, the developed action plans to address the issues extubation decreased form 2.9 unplanned extubations per 100 intubated patient days in the first year to 0.6 in the last year (p = 0.0001). This reduction was the result of a decrease in unplanned extubation in children younger than 2 years of age. Although mortality was similar to that of Children who did not experience an unplanned extubation, those with an unplanned extubation had a significantly longer duration of mechanical ventilation, longer stay in the intensive care unit, and longer hospital stay. We found that the implementation of a continuous quality improvement programme is effective in reducing the overall incidence of unplanned extubations. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-11-01 2016-01-24T13:51:47Z 2016-01-24T13:51:47Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1111/j.1365-2044.2008.05628.x Anaesthesia. Malden: Wiley-Blackwell Publishing, Inc, v. 63, n. 11, p. 1209-1216, 2008. 10.1111/j.1365-2044.2008.05628.x 0003-2409 http://repositorio.unifesp.br/handle/11600/30982 WOS:000259937300009 |
url |
http://dx.doi.org/10.1111/j.1365-2044.2008.05628.x http://repositorio.unifesp.br/handle/11600/30982 |
identifier_str_mv |
Anaesthesia. Malden: Wiley-Blackwell Publishing, Inc, v. 63, n. 11, p. 1209-1216, 2008. 10.1111/j.1365-2044.2008.05628.x 0003-2409 WOS:000259937300009 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Anaesthesia |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess http://olabout.wiley.com/WileyCDA/Section/id-406071.html |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://olabout.wiley.com/WileyCDA/Section/id-406071.html |
dc.format.none.fl_str_mv |
1209-1216 |
dc.publisher.none.fl_str_mv |
Wiley-Blackwell |
publisher.none.fl_str_mv |
Wiley-Blackwell |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1814268411406974976 |