Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum

Detalhes bibliográficos
Autor(a) principal: Azevedo, Otávio Cansanção [UNIFESP]
Data de Publicação: 2006
Outros Autores: Azevedo, João Luiz Moreira Coutinho [UNIFESP], Sorbello, Albino Augusto, Miguel, Gustavo Peixoto Soares [UNIFESP], Guindalini, Rodrigo Santa Cruz [UNIFESP], Godoy, Antônio Cláudio de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S0102-86502006000500005
http://repositorio.unifesp.br/handle/11600/3270
Resumo: PURPOSE: To test the efficacy of the puncture in the left hypochondrium as an alternative method. METHODS: Sixty-two patients randomly distributed into two groups were studied: Group LH, puncture in the left hypochondrium (n=30), and Group ML, puncture in the abdominal midline (n=32). The following were assessed: needle positioning tests, number of failed attempts at needle insertion, and time needed for creation of pneumoperitoneum. Gas flow, volume and intraperitoneal pressure were recorded at every 20 seconds, until a 12 mmHg pressure was reached inside the peritoneal cavity. RESULTS: A similar number of positive results for the needle positioning tests were observed in both groups. Two failed attempts to reach the peritoneal cavity were observed in Group ML and one in Group LH. The time necessary for the creation of pneumoperitoneum was on average 3 minutes and 46 seconds for Group LH, and 4 minutes and 2 seconds for Group ML. Average gas flow, volume and pressure were equivalent for both groups. CONCLUSION: Puncture in the left hypochondrium was as effective as puncture in the abdominal midline for the creation of pneumoperitoneum.
id UFSP_5d0831c1c6134b85d642d3734c4357b6
oai_identifier_str oai:repositorio.unifesp.br/:11600/3270
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneumPunção no hipocôndrio esquerdo com agulha de Veress para a criação do pneumoperitônioLaparoscopySurgeryPneumoperitoneum, ArtificialPuncturesLaparoscopiaCirurgiaPneumoperitônio ArtificialPunçõesPURPOSE: To test the efficacy of the puncture in the left hypochondrium as an alternative method. METHODS: Sixty-two patients randomly distributed into two groups were studied: Group LH, puncture in the left hypochondrium (n=30), and Group ML, puncture in the abdominal midline (n=32). The following were assessed: needle positioning tests, number of failed attempts at needle insertion, and time needed for creation of pneumoperitoneum. Gas flow, volume and intraperitoneal pressure were recorded at every 20 seconds, until a 12 mmHg pressure was reached inside the peritoneal cavity. RESULTS: A similar number of positive results for the needle positioning tests were observed in both groups. Two failed attempts to reach the peritoneal cavity were observed in Group ML and one in Group LH. The time necessary for the creation of pneumoperitoneum was on average 3 minutes and 46 seconds for Group LH, and 4 minutes and 2 seconds for Group ML. Average gas flow, volume and pressure were equivalent for both groups. CONCLUSION: Puncture in the left hypochondrium was as effective as puncture in the abdominal midline for the creation of pneumoperitoneum.OBJETIVO: Avaliar a eficácia e segurança da punção alternativa no hipocôndrio esquerdo. MÉTODOS: Sessenta e dois pacientes distribuídos aleatoriamente em dois grupos foram estudados prospectivamente: grupo HE, punção no hipocôndrio esquerdo (n=30) e grupo LM, punção na linha média do abdome (n=32). Foram avaliados os testes de posicionamento da agulha, o número de tentativas frustradas e a duração da instalação do pneumoperitônio. Os fluxos correntes, as pressões intraperitoneais e os volumes injetados foram registrados a cada 20 segundos, até 12 mmHg. RESULTADOS: O número de resultados positivos aos testes de posicionamento da agulha foi semelhante em ambos os grupos. Ocorreram duas tentativas infrutíferas de punção no grupo LM e uma no grupo HE. O tempo necessário para o estabelecimento do pneumoperitônio foi, em média, 3 minutos e 46 segundos para o Grupo HE e 4 minutos e 2 segundos para o grupo LM. As médias dos fluxos, das pressões e dos volumes foram respectivamente equivalentes entre os grupos.. CONCLUSÃO: A punção no HE foi tão eficaz no estabelecimento do pneumoperitônio quanto a punção na LM do abdome.UNIFESPUniversidade Federal de São Paulo (UNIFESP) Department of SurgeryHospital of the State of São PauloUNIFESP, Department of SurgerySciELOSociedade Brasileira para o Desenvolvimento da Pesquisa em CirurgiaUniversidade Federal de São Paulo (UNIFESP)Hospital of the State of São PauloAzevedo, Otávio Cansanção [UNIFESP]Azevedo, João Luiz Moreira Coutinho [UNIFESP]Sorbello, Albino AugustoMiguel, Gustavo Peixoto Soares [UNIFESP]Guindalini, Rodrigo Santa Cruz [UNIFESP]Godoy, Antônio Cláudio de2015-06-14T13:36:27Z2015-06-14T13:36:27Z2006-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion296-303application/pdfhttp://dx.doi.org/10.1590/S0102-86502006000500005Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 21, n. 5, p. 296-303, 2006.10.1590/S0102-86502006000500005S0102-86502006000500005.pdf0102-8650S0102-86502006000500005http://repositorio.unifesp.br/handle/11600/3270engActa Cirurgica Brasileirainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-04T20:58:51Zoai:repositorio.unifesp.br/:11600/3270Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-04T20:58:51Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum
Punção no hipocôndrio esquerdo com agulha de Veress para a criação do pneumoperitônio
title Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum
spellingShingle Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum
Azevedo, Otávio Cansanção [UNIFESP]
Laparoscopy
Surgery
Pneumoperitoneum, Artificial
Punctures
Laparoscopia
Cirurgia
Pneumoperitônio Artificial
Punções
title_short Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum
title_full Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum
title_fullStr Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum
title_full_unstemmed Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum
title_sort Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum
author Azevedo, Otávio Cansanção [UNIFESP]
author_facet Azevedo, Otávio Cansanção [UNIFESP]
Azevedo, João Luiz Moreira Coutinho [UNIFESP]
Sorbello, Albino Augusto
Miguel, Gustavo Peixoto Soares [UNIFESP]
Guindalini, Rodrigo Santa Cruz [UNIFESP]
Godoy, Antônio Cláudio de
author_role author
author2 Azevedo, João Luiz Moreira Coutinho [UNIFESP]
Sorbello, Albino Augusto
Miguel, Gustavo Peixoto Soares [UNIFESP]
Guindalini, Rodrigo Santa Cruz [UNIFESP]
Godoy, Antônio Cláudio de
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
Hospital of the State of São Paulo
dc.contributor.author.fl_str_mv Azevedo, Otávio Cansanção [UNIFESP]
Azevedo, João Luiz Moreira Coutinho [UNIFESP]
Sorbello, Albino Augusto
Miguel, Gustavo Peixoto Soares [UNIFESP]
Guindalini, Rodrigo Santa Cruz [UNIFESP]
Godoy, Antônio Cláudio de
dc.subject.por.fl_str_mv Laparoscopy
Surgery
Pneumoperitoneum, Artificial
Punctures
Laparoscopia
Cirurgia
Pneumoperitônio Artificial
Punções
topic Laparoscopy
Surgery
Pneumoperitoneum, Artificial
Punctures
Laparoscopia
Cirurgia
Pneumoperitônio Artificial
Punções
description PURPOSE: To test the efficacy of the puncture in the left hypochondrium as an alternative method. METHODS: Sixty-two patients randomly distributed into two groups were studied: Group LH, puncture in the left hypochondrium (n=30), and Group ML, puncture in the abdominal midline (n=32). The following were assessed: needle positioning tests, number of failed attempts at needle insertion, and time needed for creation of pneumoperitoneum. Gas flow, volume and intraperitoneal pressure were recorded at every 20 seconds, until a 12 mmHg pressure was reached inside the peritoneal cavity. RESULTS: A similar number of positive results for the needle positioning tests were observed in both groups. Two failed attempts to reach the peritoneal cavity were observed in Group ML and one in Group LH. The time necessary for the creation of pneumoperitoneum was on average 3 minutes and 46 seconds for Group LH, and 4 minutes and 2 seconds for Group ML. Average gas flow, volume and pressure were equivalent for both groups. CONCLUSION: Puncture in the left hypochondrium was as effective as puncture in the abdominal midline for the creation of pneumoperitoneum.
publishDate 2006
dc.date.none.fl_str_mv 2006-10-01
2015-06-14T13:36:27Z
2015-06-14T13:36:27Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0102-86502006000500005
Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 21, n. 5, p. 296-303, 2006.
10.1590/S0102-86502006000500005
S0102-86502006000500005.pdf
0102-8650
S0102-86502006000500005
http://repositorio.unifesp.br/handle/11600/3270
url http://dx.doi.org/10.1590/S0102-86502006000500005
http://repositorio.unifesp.br/handle/11600/3270
identifier_str_mv Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 21, n. 5, p. 296-303, 2006.
10.1590/S0102-86502006000500005
S0102-86502006000500005.pdf
0102-8650
S0102-86502006000500005
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Acta Cirurgica Brasileira
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 296-303
application/pdf
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268396471058432