Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNIFESP |
Texto Completo: | http://dx.doi.org/10.1590/S0102-86502006000500005 http://repositorio.unifesp.br/handle/11600/3270 |
Resumo: | PURPOSE: To test the efficacy of the puncture in the left hypochondrium as an alternative method. METHODS: Sixty-two patients randomly distributed into two groups were studied: Group LH, puncture in the left hypochondrium (n=30), and Group ML, puncture in the abdominal midline (n=32). The following were assessed: needle positioning tests, number of failed attempts at needle insertion, and time needed for creation of pneumoperitoneum. Gas flow, volume and intraperitoneal pressure were recorded at every 20 seconds, until a 12 mmHg pressure was reached inside the peritoneal cavity. RESULTS: A similar number of positive results for the needle positioning tests were observed in both groups. Two failed attempts to reach the peritoneal cavity were observed in Group ML and one in Group LH. The time necessary for the creation of pneumoperitoneum was on average 3 minutes and 46 seconds for Group LH, and 4 minutes and 2 seconds for Group ML. Average gas flow, volume and pressure were equivalent for both groups. CONCLUSION: Puncture in the left hypochondrium was as effective as puncture in the abdominal midline for the creation of pneumoperitoneum. |
id |
UFSP_5d0831c1c6134b85d642d3734c4357b6 |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/3270 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneumPunção no hipocôndrio esquerdo com agulha de Veress para a criação do pneumoperitônioLaparoscopySurgeryPneumoperitoneum, ArtificialPuncturesLaparoscopiaCirurgiaPneumoperitônio ArtificialPunçõesPURPOSE: To test the efficacy of the puncture in the left hypochondrium as an alternative method. METHODS: Sixty-two patients randomly distributed into two groups were studied: Group LH, puncture in the left hypochondrium (n=30), and Group ML, puncture in the abdominal midline (n=32). The following were assessed: needle positioning tests, number of failed attempts at needle insertion, and time needed for creation of pneumoperitoneum. Gas flow, volume and intraperitoneal pressure were recorded at every 20 seconds, until a 12 mmHg pressure was reached inside the peritoneal cavity. RESULTS: A similar number of positive results for the needle positioning tests were observed in both groups. Two failed attempts to reach the peritoneal cavity were observed in Group ML and one in Group LH. The time necessary for the creation of pneumoperitoneum was on average 3 minutes and 46 seconds for Group LH, and 4 minutes and 2 seconds for Group ML. Average gas flow, volume and pressure were equivalent for both groups. CONCLUSION: Puncture in the left hypochondrium was as effective as puncture in the abdominal midline for the creation of pneumoperitoneum.OBJETIVO: Avaliar a eficácia e segurança da punção alternativa no hipocôndrio esquerdo. MÉTODOS: Sessenta e dois pacientes distribuídos aleatoriamente em dois grupos foram estudados prospectivamente: grupo HE, punção no hipocôndrio esquerdo (n=30) e grupo LM, punção na linha média do abdome (n=32). Foram avaliados os testes de posicionamento da agulha, o número de tentativas frustradas e a duração da instalação do pneumoperitônio. Os fluxos correntes, as pressões intraperitoneais e os volumes injetados foram registrados a cada 20 segundos, até 12 mmHg. RESULTADOS: O número de resultados positivos aos testes de posicionamento da agulha foi semelhante em ambos os grupos. Ocorreram duas tentativas infrutíferas de punção no grupo LM e uma no grupo HE. O tempo necessário para o estabelecimento do pneumoperitônio foi, em média, 3 minutos e 46 segundos para o Grupo HE e 4 minutos e 2 segundos para o grupo LM. As médias dos fluxos, das pressões e dos volumes foram respectivamente equivalentes entre os grupos.. CONCLUSÃO: A punção no HE foi tão eficaz no estabelecimento do pneumoperitônio quanto a punção na LM do abdome.UNIFESPUniversidade Federal de São Paulo (UNIFESP) Department of SurgeryHospital of the State of São PauloUNIFESP, Department of SurgerySciELOSociedade Brasileira para o Desenvolvimento da Pesquisa em CirurgiaUniversidade Federal de São Paulo (UNIFESP)Hospital of the State of São PauloAzevedo, Otávio Cansanção [UNIFESP]Azevedo, João Luiz Moreira Coutinho [UNIFESP]Sorbello, Albino AugustoMiguel, Gustavo Peixoto Soares [UNIFESP]Guindalini, Rodrigo Santa Cruz [UNIFESP]Godoy, Antônio Cláudio de2015-06-14T13:36:27Z2015-06-14T13:36:27Z2006-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion296-303application/pdfhttp://dx.doi.org/10.1590/S0102-86502006000500005Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 21, n. 5, p. 296-303, 2006.10.1590/S0102-86502006000500005S0102-86502006000500005.pdf0102-8650S0102-86502006000500005http://repositorio.unifesp.br/handle/11600/3270engActa Cirurgica Brasileirainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-04T20:58:51Zoai:repositorio.unifesp.br/:11600/3270Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-04T20:58:51Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum Punção no hipocôndrio esquerdo com agulha de Veress para a criação do pneumoperitônio |
title |
Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum |
spellingShingle |
Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum Azevedo, Otávio Cansanção [UNIFESP] Laparoscopy Surgery Pneumoperitoneum, Artificial Punctures Laparoscopia Cirurgia Pneumoperitônio Artificial Punções |
title_short |
Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum |
title_full |
Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum |
title_fullStr |
Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum |
title_full_unstemmed |
Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum |
title_sort |
Veress needle insertion in the left hypochondrium in creation of the pneumoperitoneum |
author |
Azevedo, Otávio Cansanção [UNIFESP] |
author_facet |
Azevedo, Otávio Cansanção [UNIFESP] Azevedo, João Luiz Moreira Coutinho [UNIFESP] Sorbello, Albino Augusto Miguel, Gustavo Peixoto Soares [UNIFESP] Guindalini, Rodrigo Santa Cruz [UNIFESP] Godoy, Antônio Cláudio de |
author_role |
author |
author2 |
Azevedo, João Luiz Moreira Coutinho [UNIFESP] Sorbello, Albino Augusto Miguel, Gustavo Peixoto Soares [UNIFESP] Guindalini, Rodrigo Santa Cruz [UNIFESP] Godoy, Antônio Cláudio de |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Federal de São Paulo (UNIFESP) Hospital of the State of São Paulo |
dc.contributor.author.fl_str_mv |
Azevedo, Otávio Cansanção [UNIFESP] Azevedo, João Luiz Moreira Coutinho [UNIFESP] Sorbello, Albino Augusto Miguel, Gustavo Peixoto Soares [UNIFESP] Guindalini, Rodrigo Santa Cruz [UNIFESP] Godoy, Antônio Cláudio de |
dc.subject.por.fl_str_mv |
Laparoscopy Surgery Pneumoperitoneum, Artificial Punctures Laparoscopia Cirurgia Pneumoperitônio Artificial Punções |
topic |
Laparoscopy Surgery Pneumoperitoneum, Artificial Punctures Laparoscopia Cirurgia Pneumoperitônio Artificial Punções |
description |
PURPOSE: To test the efficacy of the puncture in the left hypochondrium as an alternative method. METHODS: Sixty-two patients randomly distributed into two groups were studied: Group LH, puncture in the left hypochondrium (n=30), and Group ML, puncture in the abdominal midline (n=32). The following were assessed: needle positioning tests, number of failed attempts at needle insertion, and time needed for creation of pneumoperitoneum. Gas flow, volume and intraperitoneal pressure were recorded at every 20 seconds, until a 12 mmHg pressure was reached inside the peritoneal cavity. RESULTS: A similar number of positive results for the needle positioning tests were observed in both groups. Two failed attempts to reach the peritoneal cavity were observed in Group ML and one in Group LH. The time necessary for the creation of pneumoperitoneum was on average 3 minutes and 46 seconds for Group LH, and 4 minutes and 2 seconds for Group ML. Average gas flow, volume and pressure were equivalent for both groups. CONCLUSION: Puncture in the left hypochondrium was as effective as puncture in the abdominal midline for the creation of pneumoperitoneum. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-10-01 2015-06-14T13:36:27Z 2015-06-14T13:36:27Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/S0102-86502006000500005 Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 21, n. 5, p. 296-303, 2006. 10.1590/S0102-86502006000500005 S0102-86502006000500005.pdf 0102-8650 S0102-86502006000500005 http://repositorio.unifesp.br/handle/11600/3270 |
url |
http://dx.doi.org/10.1590/S0102-86502006000500005 http://repositorio.unifesp.br/handle/11600/3270 |
identifier_str_mv |
Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 21, n. 5, p. 296-303, 2006. 10.1590/S0102-86502006000500005 S0102-86502006000500005.pdf 0102-8650 S0102-86502006000500005 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Acta Cirurgica Brasileira |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
296-303 application/pdf |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1814268396471058432 |