Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol

Detalhes bibliográficos
Autor(a) principal: Raduan Neto, Jorge [UNIFESP]
Data de Publicação: 2014
Outros Autores: Moraes, Vinicius Ynoe de [UNIFESP], Santos, João Baptista Gomes dos [UNIFESP], Faloppa, Flávio [UNIFESP], Belloti, João Carlos [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://repositorio.unifesp.br/handle/11600/37543
http://dx.doi.org/10.1186/1471-2474-15-65
Resumo: Background: Various treatments are available for reducible unstable fractures of the distal radius, such as closed reduction combined with fixation by external fixator (EF), and rigid internal fixation using a locked volar plate (VP). Although there are studies comparing these methods, there is no conclusive evidence indicating which treatment is best. the hypothesis of this study is that surgical treatment with a VP is more effective than EF from the standpoint of functional outcome (patient-reported).Methods/Design: the study is randomized clinical trial with parallel groups and a blinded evaluator and involves the surgical interventions EF and VP. Patients will be randomly assigned (assignment ratio 1: 1) using sealed opaque envelopes. This trial will include consecutive adult patients with an acute (up to 15 days) displaced, unstable fracture of the distal end of the radius of type A2, A3, C1, C2 or C3 by the Arbeitsgemeinschaft fur Osteosynthesefragen-Association for the Study of Internal Fixation classification and type II or type III by the IDEAL(32) classification, without previous surgical treatments of the wrist. the surgical intervention assigned will be performed by three surgical specialists familiar with the techniques described. Evaluations will be performed at 2, and 8 weeks, 3, 6 and 12 months, with the primary outcomes being measured by the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and measurement of pain (Visual Analog Pain Scale and digital algometer). Secondary outcomes will include radiographic parameters, objective functional evaluation (goniometry and dynamometry), and the rate of complications and method failure according to the intention-to-treat principle. Final postoperative evaluations (6 and 12 months) will be performed by independent blinded evaluators. for the Student's t-test, a difference of 10 points in the DASH score, with a 95% confidence interval, a statistical power of 80%, and 20% sampling error results in 36 patients per group.Discussion: Results from this study protocol will improve the current evidence regarding to the surgical treatment these fractures.
id UFSP_5eba8a224d8aa12d0bcd45062ceb203e
oai_identifier_str oai:repositorio.unifesp.br:11600/37543
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Raduan Neto, Jorge [UNIFESP]Moraes, Vinicius Ynoe de [UNIFESP]Santos, João Baptista Gomes dos [UNIFESP]Faloppa, Flávio [UNIFESP]Belloti, João Carlos [UNIFESP]Universidade Federal de São Paulo (UNIFESP)Hand Arm & Shoulder Surg Unit2016-01-24T14:35:26Z2016-01-24T14:35:26Z2014-03-05Bmc Musculoskeletal Disorders. London: Biomed Central Ltd, v. 15, 7 p., 2014.1471-2474http://repositorio.unifesp.br/handle/11600/37543http://dx.doi.org/10.1186/1471-2474-15-65WOS000335176600001.pdf10.1186/1471-2474-15-65WOS:000335176600001Background: Various treatments are available for reducible unstable fractures of the distal radius, such as closed reduction combined with fixation by external fixator (EF), and rigid internal fixation using a locked volar plate (VP). Although there are studies comparing these methods, there is no conclusive evidence indicating which treatment is best. the hypothesis of this study is that surgical treatment with a VP is more effective than EF from the standpoint of functional outcome (patient-reported).Methods/Design: the study is randomized clinical trial with parallel groups and a blinded evaluator and involves the surgical interventions EF and VP. Patients will be randomly assigned (assignment ratio 1: 1) using sealed opaque envelopes. This trial will include consecutive adult patients with an acute (up to 15 days) displaced, unstable fracture of the distal end of the radius of type A2, A3, C1, C2 or C3 by the Arbeitsgemeinschaft fur Osteosynthesefragen-Association for the Study of Internal Fixation classification and type II or type III by the IDEAL(32) classification, without previous surgical treatments of the wrist. the surgical intervention assigned will be performed by three surgical specialists familiar with the techniques described. Evaluations will be performed at 2, and 8 weeks, 3, 6 and 12 months, with the primary outcomes being measured by the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and measurement of pain (Visual Analog Pain Scale and digital algometer). Secondary outcomes will include radiographic parameters, objective functional evaluation (goniometry and dynamometry), and the rate of complications and method failure according to the intention-to-treat principle. Final postoperative evaluations (6 and 12 months) will be performed by independent blinded evaluators. for the Student's t-test, a difference of 10 points in the DASH score, with a 95% confidence interval, a statistical power of 80%, and 20% sampling error results in 36 patients per group.Discussion: Results from this study protocol will improve the current evidence regarding to the surgical treatment these fractures.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Universidade Federal de São Paulo, UNIFESP EPM, Dept Orthoped & Traumatol, Hand Arm & Shoulder Surg Unit, São Paulo, BrazilHand Arm & Shoulder Surg Unit, São Paulo, BrazilUniversidade Federal de São Paulo, UNIFESP EPM, Dept Orthoped & Traumatol, Hand Arm & Shoulder Surg Unit, São Paulo, BrazilFAPESP: FAPESP - 2012/00806-2- annex 3Web of Science7engBiomed Central LtdBmc Musculoskeletal DisordersDistal radius fractureVolar plateExternal fixatorRandomizedProspective (annex 1)Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocolinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESPORIGINALWOS000335176600001.pdfapplication/pdf466309${dspace.ui.url}/bitstream/11600/37543/1/WOS000335176600001.pdfce59da4355579aad3a6fb4b5c31bfcc1MD51open accessTEXTWOS000335176600001.pdf.txtWOS000335176600001.pdf.txtExtracted texttext/plain31371${dspace.ui.url}/bitstream/11600/37543/21/WOS000335176600001.pdf.txtec1a986848fbd2736782ea6dbeec3b9dMD521open accessTHUMBNAILWOS000335176600001.pdf.jpgWOS000335176600001.pdf.jpgIM Thumbnailimage/jpeg6626${dspace.ui.url}/bitstream/11600/37543/23/WOS000335176600001.pdf.jpg37c0a577d0c9c6063766ef505fa03df2MD523open access11600/375432023-06-05 20:15:21.798open accessoai:repositorio.unifesp.br:11600/37543Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestopendoar:34652023-06-05T23:15:21Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.en.fl_str_mv Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
title Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
spellingShingle Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
Raduan Neto, Jorge [UNIFESP]
Distal radius fracture
Volar plate
External fixator
Randomized
Prospective (annex 1)
title_short Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
title_full Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
title_fullStr Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
title_full_unstemmed Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
title_sort Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
author Raduan Neto, Jorge [UNIFESP]
author_facet Raduan Neto, Jorge [UNIFESP]
Moraes, Vinicius Ynoe de [UNIFESP]
Santos, João Baptista Gomes dos [UNIFESP]
Faloppa, Flávio [UNIFESP]
Belloti, João Carlos [UNIFESP]
author_role author
author2 Moraes, Vinicius Ynoe de [UNIFESP]
Santos, João Baptista Gomes dos [UNIFESP]
Faloppa, Flávio [UNIFESP]
Belloti, João Carlos [UNIFESP]
author2_role author
author
author
author
dc.contributor.institution.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
Hand Arm & Shoulder Surg Unit
dc.contributor.author.fl_str_mv Raduan Neto, Jorge [UNIFESP]
Moraes, Vinicius Ynoe de [UNIFESP]
Santos, João Baptista Gomes dos [UNIFESP]
Faloppa, Flávio [UNIFESP]
Belloti, João Carlos [UNIFESP]
dc.subject.eng.fl_str_mv Distal radius fracture
Volar plate
External fixator
Randomized
Prospective (annex 1)
topic Distal radius fracture
Volar plate
External fixator
Randomized
Prospective (annex 1)
description Background: Various treatments are available for reducible unstable fractures of the distal radius, such as closed reduction combined with fixation by external fixator (EF), and rigid internal fixation using a locked volar plate (VP). Although there are studies comparing these methods, there is no conclusive evidence indicating which treatment is best. the hypothesis of this study is that surgical treatment with a VP is more effective than EF from the standpoint of functional outcome (patient-reported).Methods/Design: the study is randomized clinical trial with parallel groups and a blinded evaluator and involves the surgical interventions EF and VP. Patients will be randomly assigned (assignment ratio 1: 1) using sealed opaque envelopes. This trial will include consecutive adult patients with an acute (up to 15 days) displaced, unstable fracture of the distal end of the radius of type A2, A3, C1, C2 or C3 by the Arbeitsgemeinschaft fur Osteosynthesefragen-Association for the Study of Internal Fixation classification and type II or type III by the IDEAL(32) classification, without previous surgical treatments of the wrist. the surgical intervention assigned will be performed by three surgical specialists familiar with the techniques described. Evaluations will be performed at 2, and 8 weeks, 3, 6 and 12 months, with the primary outcomes being measured by the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and measurement of pain (Visual Analog Pain Scale and digital algometer). Secondary outcomes will include radiographic parameters, objective functional evaluation (goniometry and dynamometry), and the rate of complications and method failure according to the intention-to-treat principle. Final postoperative evaluations (6 and 12 months) will be performed by independent blinded evaluators. for the Student's t-test, a difference of 10 points in the DASH score, with a 95% confidence interval, a statistical power of 80%, and 20% sampling error results in 36 patients per group.Discussion: Results from this study protocol will improve the current evidence regarding to the surgical treatment these fractures.
publishDate 2014
dc.date.issued.fl_str_mv 2014-03-05
dc.date.accessioned.fl_str_mv 2016-01-24T14:35:26Z
dc.date.available.fl_str_mv 2016-01-24T14:35:26Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.citation.fl_str_mv Bmc Musculoskeletal Disorders. London: Biomed Central Ltd, v. 15, 7 p., 2014.
dc.identifier.uri.fl_str_mv http://repositorio.unifesp.br/handle/11600/37543
http://dx.doi.org/10.1186/1471-2474-15-65
dc.identifier.issn.none.fl_str_mv 1471-2474
dc.identifier.file.none.fl_str_mv WOS000335176600001.pdf
dc.identifier.doi.none.fl_str_mv 10.1186/1471-2474-15-65
dc.identifier.wos.none.fl_str_mv WOS:000335176600001
identifier_str_mv Bmc Musculoskeletal Disorders. London: Biomed Central Ltd, v. 15, 7 p., 2014.
1471-2474
WOS000335176600001.pdf
10.1186/1471-2474-15-65
WOS:000335176600001
url http://repositorio.unifesp.br/handle/11600/37543
http://dx.doi.org/10.1186/1471-2474-15-65
dc.language.iso.fl_str_mv eng
language eng
dc.relation.ispartof.none.fl_str_mv Bmc Musculoskeletal Disorders
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 7
dc.publisher.none.fl_str_mv Biomed Central Ltd
publisher.none.fl_str_mv Biomed Central Ltd
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
bitstream.url.fl_str_mv ${dspace.ui.url}/bitstream/11600/37543/1/WOS000335176600001.pdf
${dspace.ui.url}/bitstream/11600/37543/21/WOS000335176600001.pdf.txt
${dspace.ui.url}/bitstream/11600/37543/23/WOS000335176600001.pdf.jpg
bitstream.checksum.fl_str_mv ce59da4355579aad3a6fb4b5c31bfcc1
ec1a986848fbd2736782ea6dbeec3b9d
37c0a577d0c9c6063766ef505fa03df2
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv
_version_ 1783460328270462976