Use of fibrinogen and thrombin sponge in pediatric split liver transplantation
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNIFESP |
Texto Completo: | http://dx.doi.org/10.1590/s0102-865020170080000009 http://repositorio.unifesp.br/handle/11600/51425 |
Resumo: | Purpose: To analyze the use of this sponge in pediatric patients undergoing split-liver transplantation. Methods: Retrospective study, including 35 pediatric patients undergoing split-liver transplantation, divided into two groups according to the use of the sponge: 18 patients in Group A (no sponge) and 17 in Group B (with sponge). Results: The characteristics of recipients and donors were similar. We observed greater number of reoperation due to bleeding in the wound area in Group A (10 patients - 55.5%) than in Group B (3 patients - 17.6%) |
id |
UFSP_65d4229fc9a1abe6d87867f51c2b21e2 |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/51425 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Use of fibrinogen and thrombin sponge in pediatric split liver transplantationLiver TransplantationHomeostasisFibrinogenThrombinPurpose: To analyze the use of this sponge in pediatric patients undergoing split-liver transplantation. Methods: Retrospective study, including 35 pediatric patients undergoing split-liver transplantation, divided into two groups according to the use of the sponge: 18 patients in Group A (no sponge) and 17 in Group B (with sponge). Results: The characteristics of recipients and donors were similar. We observed greater number of reoperation due to bleeding in the wound area in Group A (10 patients - 55.5%) than in Group B (3 patients - 17.6%)p = 0.035. The median volume of red blood cells transfused in Group A was significantly higher (73.4 +/- 102.38 mL/kg) than that in Group B (35.1 +/- 41.67 mL/kg)p = 0.048. Regarding bile leak there was no statistical difference. Conclusion: The use of the human fibrinogen and thrombin sponge, required lower volume of red blood cell transfusion and presented lower reoperation rates due to bleeding in the wound area.Univ Fed São Paulo UNIFESP, Postgrad Program Interdisciplinary Surg Sci, São Paulo, BrazilUniv Fed São Paulo, Dept Surg, Div Surg Gastroenterol, São Paulo, SP, BrazilUniv Fed São Paulo, Dept Surg, Div Pediat Surg, São Paulo, SP, BrazilUniv Fed São Paulo UNIFESP, Dept Surg, Div Surg Gastroenterol, São Paulo, SP, BrazilUniv Fed São Paulo UNIFESP, Postgrad Program Interdisciplinary Surg Sci, São Paulo, BrazilUniv Fed São Paulo, Dept Surg, Div Surg Gastroenterol, São Paulo, SP, BrazilUniv Fed São Paulo, Dept Surg, Div Pediat Surg, São Paulo, SP, BrazilUniv Fed São Paulo UNIFESP, Dept Surg, Div Surg Gastroenterol, São Paulo, SP, BrazilWeb of ScienceActa Cirurgica Brasileira2019-08-19T11:49:53Z2019-08-19T11:49:53Z2017info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion673-679application/pdfhttp://dx.doi.org/10.1590/s0102-865020170080000009Acta Cirurgica Brasileira. Sao Paulo, v. 32, n. 8, p. 673-679, 2017.10.1590/s0102-865020170080000009WOS000410613900009.pdf0102-8650S0102-86502017000800673http://repositorio.unifesp.br/handle/11600/51425WOS:000410613900009enginfo:eu-repo/semantics/openAccessPiza Vicentine, Fernando Pompeu [UNIFESP]Gonzalez, Adriano Miziara [UNIFESP]Beninni, Barbara Burza [UNIFESP]de Azevedo, Ramiro Anthero [UNIFESP]Linhares, Marcelo Moura [UNIFESP]Goldenberg, Alberto [UNIFESP]Lopes Filho, Gaspar de Jesus [UNIFESP]Martins, Jose Luiz [UNIFESP]Salzedas Netto, Alcides Augusto [UNIFESP]reponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-10T23:42:26Zoai:repositorio.unifesp.br/:11600/51425Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-10T23:42:26Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Use of fibrinogen and thrombin sponge in pediatric split liver transplantation |
title |
Use of fibrinogen and thrombin sponge in pediatric split liver transplantation |
spellingShingle |
Use of fibrinogen and thrombin sponge in pediatric split liver transplantation Piza Vicentine, Fernando Pompeu [UNIFESP] Liver Transplantation Homeostasis Fibrinogen Thrombin |
title_short |
Use of fibrinogen and thrombin sponge in pediatric split liver transplantation |
title_full |
Use of fibrinogen and thrombin sponge in pediatric split liver transplantation |
title_fullStr |
Use of fibrinogen and thrombin sponge in pediatric split liver transplantation |
title_full_unstemmed |
Use of fibrinogen and thrombin sponge in pediatric split liver transplantation |
title_sort |
Use of fibrinogen and thrombin sponge in pediatric split liver transplantation |
author |
Piza Vicentine, Fernando Pompeu [UNIFESP] |
author_facet |
Piza Vicentine, Fernando Pompeu [UNIFESP] Gonzalez, Adriano Miziara [UNIFESP] Beninni, Barbara Burza [UNIFESP] de Azevedo, Ramiro Anthero [UNIFESP] Linhares, Marcelo Moura [UNIFESP] Goldenberg, Alberto [UNIFESP] Lopes Filho, Gaspar de Jesus [UNIFESP] Martins, Jose Luiz [UNIFESP] Salzedas Netto, Alcides Augusto [UNIFESP] |
author_role |
author |
author2 |
Gonzalez, Adriano Miziara [UNIFESP] Beninni, Barbara Burza [UNIFESP] de Azevedo, Ramiro Anthero [UNIFESP] Linhares, Marcelo Moura [UNIFESP] Goldenberg, Alberto [UNIFESP] Lopes Filho, Gaspar de Jesus [UNIFESP] Martins, Jose Luiz [UNIFESP] Salzedas Netto, Alcides Augusto [UNIFESP] |
author2_role |
author author author author author author author author |
dc.contributor.author.fl_str_mv |
Piza Vicentine, Fernando Pompeu [UNIFESP] Gonzalez, Adriano Miziara [UNIFESP] Beninni, Barbara Burza [UNIFESP] de Azevedo, Ramiro Anthero [UNIFESP] Linhares, Marcelo Moura [UNIFESP] Goldenberg, Alberto [UNIFESP] Lopes Filho, Gaspar de Jesus [UNIFESP] Martins, Jose Luiz [UNIFESP] Salzedas Netto, Alcides Augusto [UNIFESP] |
dc.subject.por.fl_str_mv |
Liver Transplantation Homeostasis Fibrinogen Thrombin |
topic |
Liver Transplantation Homeostasis Fibrinogen Thrombin |
description |
Purpose: To analyze the use of this sponge in pediatric patients undergoing split-liver transplantation. Methods: Retrospective study, including 35 pediatric patients undergoing split-liver transplantation, divided into two groups according to the use of the sponge: 18 patients in Group A (no sponge) and 17 in Group B (with sponge). Results: The characteristics of recipients and donors were similar. We observed greater number of reoperation due to bleeding in the wound area in Group A (10 patients - 55.5%) than in Group B (3 patients - 17.6%) |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017 2019-08-19T11:49:53Z 2019-08-19T11:49:53Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/s0102-865020170080000009 Acta Cirurgica Brasileira. Sao Paulo, v. 32, n. 8, p. 673-679, 2017. 10.1590/s0102-865020170080000009 WOS000410613900009.pdf 0102-8650 S0102-86502017000800673 http://repositorio.unifesp.br/handle/11600/51425 WOS:000410613900009 |
url |
http://dx.doi.org/10.1590/s0102-865020170080000009 http://repositorio.unifesp.br/handle/11600/51425 |
identifier_str_mv |
Acta Cirurgica Brasileira. Sao Paulo, v. 32, n. 8, p. 673-679, 2017. 10.1590/s0102-865020170080000009 WOS000410613900009.pdf 0102-8650 S0102-86502017000800673 WOS:000410613900009 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
673-679 application/pdf |
dc.publisher.none.fl_str_mv |
Acta Cirurgica Brasileira |
publisher.none.fl_str_mv |
Acta Cirurgica Brasileira |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1814268327575420928 |