Cytological features of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantation
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNIFESP |
Texto Completo: | http://dx.doi.org/10.1590/S0004-27492011000400003 http://repositorio.unifesp.br/handle/11600/6537 |
Resumo: | PURPOSE: To evaluate by impression cytology (IC) the corneal surface of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantation (LSCT). METHODS: Twenty limbal donors were enrolled (17 for autograft LSCT and 3 for allograft). Impression cytology was performed before transplantation of superior and inferior limbal grafts and after the third postoperative month. RESULTS: Impression cytology analysis showed sheets of corneal epithelial cells and goblet cell absence beyond the edge of the keratectomy sites in all patients, suggesting that conjunctival invasion towards the center did not occur in any eye. Partial conjunctivalization within 2 to 3 clock hours, confirmed by the presence of goblet cells, was limited to the keratectomy site in 10% of the cases. CONCLUSION: A clear central corneal surface was demonstrated in all eyes following surgery leading to the conclusion that limbal donation was a safe procedure in this group of patients. A small percentage of eyes can have donor sites re-epithelized with conjunctival cells at the periphery of the cornea. |
id |
UFSP_6a2761f11230288e34dd35d2d1d29935 |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/6537 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Cytological features of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantationCaracterísticas citológicas do tecido límbico de doador vivo para transplante autólogo ou alógeno de células-tronco epiteliais corneaisStem cellsCytological techniquesLimbus corneaeGoblet cellsEpithelial cellsLiving donorsTransplantation, autologousCélulas-troncoTécnicas citológicasLimbo da córneaCélulas caliciformesCélulas epiteliaisDoadores vivosTransplante autólogoPURPOSE: To evaluate by impression cytology (IC) the corneal surface of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantation (LSCT). METHODS: Twenty limbal donors were enrolled (17 for autograft LSCT and 3 for allograft). Impression cytology was performed before transplantation of superior and inferior limbal grafts and after the third postoperative month. RESULTS: Impression cytology analysis showed sheets of corneal epithelial cells and goblet cell absence beyond the edge of the keratectomy sites in all patients, suggesting that conjunctival invasion towards the center did not occur in any eye. Partial conjunctivalization within 2 to 3 clock hours, confirmed by the presence of goblet cells, was limited to the keratectomy site in 10% of the cases. CONCLUSION: A clear central corneal surface was demonstrated in all eyes following surgery leading to the conclusion that limbal donation was a safe procedure in this group of patients. A small percentage of eyes can have donor sites re-epithelized with conjunctival cells at the periphery of the cornea.OBJETIVO: Avaliar pela citologia de impressão a superfície da córnea de doador vivo para transplante autólogo ou alógeno de células-tronco epiteliais. MÉTODOS: Vinte pacientes doadores de tecido límbico foram avaliados (17 para transplante autólogo e 3 para alógeno). Os exames citológicos foram realizados em dois momentos: antes da ceratectomia, que removeu tecido límbico dos quadrantes superior e inferior, e após o terceiro mês pós-operatório. RESULTADOS: Invasão de células da conjuntiva em direção ao centro além da margem da ceratectomia não ocorreu em nenhum olho estudado. Uma pequena área de conjuntivalização parcial, confirmada pela presença de células caliciformes, foi detectada dentro do limite da ceratectomia em 10% dos casos. CONCLUSÃO: A superfície central da córnea manteve-se transparente demonstrando que a manipulação de tecido límbico em doador vivo foi um procedimento seguro neste grupo de pacientes. Uma pequena porcentagem dos olhos pode ter o local do sítio da ceratectomia re-epitelizado com células da conjuntiva sobre a periferia da córnea.Universidade Federal de São Paulo (UNIFESP) Department of OphthalmologyUniversidade Federal de São Paulo (UNIFESP) Department of Ophthalmology External Diseases and Cornea ServiceUNIFESP, Department of OphthalmologyUNIFESP, Department of Ophthalmology External Diseases and Cornea ServiceSciELOConselho Brasileiro de OftalmologiaUniversidade Federal de São Paulo (UNIFESP)Barros, Jeison de Nadai [UNIFESP]Santos, Myrna Serapião dos [UNIFESP]Barreiro, Telma Regina Maria Pereira [UNIFESP]Belfort, Rubens Junior [UNIFESP]Gomes, José Álvaro Pereira [UNIFESP]2015-06-14T13:43:10Z2015-06-14T13:43:10Z2011-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion248-250application/pdfhttp://dx.doi.org/10.1590/S0004-27492011000400003Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 74, n. 4, p. 248-250, 2011.10.1590/S0004-27492011000400003S0004-27492011000400003.pdf0004-2749S0004-27492011000400003http://repositorio.unifesp.br/handle/11600/6537WOS:000298296300003engArquivos Brasileiros de Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-07-29T11:05:41Zoai:repositorio.unifesp.br/:11600/6537Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-07-29T11:05:41Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Cytological features of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantation Características citológicas do tecido límbico de doador vivo para transplante autólogo ou alógeno de células-tronco epiteliais corneais |
title |
Cytological features of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantation |
spellingShingle |
Cytological features of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantation Barros, Jeison de Nadai [UNIFESP] Stem cells Cytological techniques Limbus corneae Goblet cells Epithelial cells Living donors Transplantation, autologous Células-tronco Técnicas citológicas Limbo da córnea Células caliciformes Células epiteliais Doadores vivos Transplante autólogo |
title_short |
Cytological features of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantation |
title_full |
Cytological features of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantation |
title_fullStr |
Cytological features of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantation |
title_full_unstemmed |
Cytological features of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantation |
title_sort |
Cytological features of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantation |
author |
Barros, Jeison de Nadai [UNIFESP] |
author_facet |
Barros, Jeison de Nadai [UNIFESP] Santos, Myrna Serapião dos [UNIFESP] Barreiro, Telma Regina Maria Pereira [UNIFESP] Belfort, Rubens Junior [UNIFESP] Gomes, José Álvaro Pereira [UNIFESP] |
author_role |
author |
author2 |
Santos, Myrna Serapião dos [UNIFESP] Barreiro, Telma Regina Maria Pereira [UNIFESP] Belfort, Rubens Junior [UNIFESP] Gomes, José Álvaro Pereira [UNIFESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Federal de São Paulo (UNIFESP) |
dc.contributor.author.fl_str_mv |
Barros, Jeison de Nadai [UNIFESP] Santos, Myrna Serapião dos [UNIFESP] Barreiro, Telma Regina Maria Pereira [UNIFESP] Belfort, Rubens Junior [UNIFESP] Gomes, José Álvaro Pereira [UNIFESP] |
dc.subject.por.fl_str_mv |
Stem cells Cytological techniques Limbus corneae Goblet cells Epithelial cells Living donors Transplantation, autologous Células-tronco Técnicas citológicas Limbo da córnea Células caliciformes Células epiteliais Doadores vivos Transplante autólogo |
topic |
Stem cells Cytological techniques Limbus corneae Goblet cells Epithelial cells Living donors Transplantation, autologous Células-tronco Técnicas citológicas Limbo da córnea Células caliciformes Células epiteliais Doadores vivos Transplante autólogo |
description |
PURPOSE: To evaluate by impression cytology (IC) the corneal surface of live limbal tissue donor eyes for autograft or allograft limbal stem cell transplantation (LSCT). METHODS: Twenty limbal donors were enrolled (17 for autograft LSCT and 3 for allograft). Impression cytology was performed before transplantation of superior and inferior limbal grafts and after the third postoperative month. RESULTS: Impression cytology analysis showed sheets of corneal epithelial cells and goblet cell absence beyond the edge of the keratectomy sites in all patients, suggesting that conjunctival invasion towards the center did not occur in any eye. Partial conjunctivalization within 2 to 3 clock hours, confirmed by the presence of goblet cells, was limited to the keratectomy site in 10% of the cases. CONCLUSION: A clear central corneal surface was demonstrated in all eyes following surgery leading to the conclusion that limbal donation was a safe procedure in this group of patients. A small percentage of eyes can have donor sites re-epithelized with conjunctival cells at the periphery of the cornea. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-08-01 2015-06-14T13:43:10Z 2015-06-14T13:43:10Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/S0004-27492011000400003 Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 74, n. 4, p. 248-250, 2011. 10.1590/S0004-27492011000400003 S0004-27492011000400003.pdf 0004-2749 S0004-27492011000400003 http://repositorio.unifesp.br/handle/11600/6537 WOS:000298296300003 |
url |
http://dx.doi.org/10.1590/S0004-27492011000400003 http://repositorio.unifesp.br/handle/11600/6537 |
identifier_str_mv |
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 74, n. 4, p. 248-250, 2011. 10.1590/S0004-27492011000400003 S0004-27492011000400003.pdf 0004-2749 S0004-27492011000400003 WOS:000298296300003 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
248-250 application/pdf |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1814268421516296192 |