Intraocular pressure and ocular perfusion during hemodialysis
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNIFESP |
Texto Completo: | http://dx.doi.org/10.1590/S0004-27492011000200007 http://repositorio.unifesp.br/handle/11600/6390 |
Resumo: | AIM: To evaluate the intraocular pressure and ocular perfusion pressure during a hemodialysis. METHODS: Sixty-seven eyes from thirty-five patients were evaluated at the beggining of hemodialysis, 2 hours and 4 hours after initiation. Intraocular pressure was evaluated using a Tonopen. Systolic and diastolic arterial pressures were measured with a manual sphygmomanometer. The ocular perfusion pressure was estimated by mea suring the difference between 2/3 of the mean arterial pressure and the intraocular pressure values. Generalized estimating equations were used to evaluate the difference between the repeated measurements using the appropriate correction for inter-eye dependency. RESULTS: There was no statistically significant difference in ocular perfusion pressure, in intraocular pressure (p=0.93) and in systolic arterial pressure (p=0.92) at the three time points (p=0.69). But, when analyzing the extreme values, some patients exhibited lower diastolic perfusion pressures at all time points. CONCLUSION: Our results did not support the view that significant changes in ocular perfusion pressure and intraocular pressure occur during hemodialysis session. However, we observed that some patients exhibited lower diastolic perfusion pressures, which could be a poor prognostic factor for glaucoma patients. |
id |
UFSP_85ce68b5851fc59e2989fa451aa2606e |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/6390 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Intraocular pressure and ocular perfusion during hemodialysisPressão intraocular e perfusão ocular durante hemodiáliseRenal dialysisRenal insufficiency, chronicIntraocular pressureGlaucomaDiálise renalInsuficiência renal crônicaPressão intraocularGlaucomaAIM: To evaluate the intraocular pressure and ocular perfusion pressure during a hemodialysis. METHODS: Sixty-seven eyes from thirty-five patients were evaluated at the beggining of hemodialysis, 2 hours and 4 hours after initiation. Intraocular pressure was evaluated using a Tonopen. Systolic and diastolic arterial pressures were measured with a manual sphygmomanometer. The ocular perfusion pressure was estimated by mea suring the difference between 2/3 of the mean arterial pressure and the intraocular pressure values. Generalized estimating equations were used to evaluate the difference between the repeated measurements using the appropriate correction for inter-eye dependency. RESULTS: There was no statistically significant difference in ocular perfusion pressure, in intraocular pressure (p=0.93) and in systolic arterial pressure (p=0.92) at the three time points (p=0.69). But, when analyzing the extreme values, some patients exhibited lower diastolic perfusion pressures at all time points. CONCLUSION: Our results did not support the view that significant changes in ocular perfusion pressure and intraocular pressure occur during hemodialysis session. However, we observed that some patients exhibited lower diastolic perfusion pressures, which could be a poor prognostic factor for glaucoma patients.OBJETIVO: Avaliar a pressão intraocular e a pressão de perfusão ocular durante uma sessão de hemodiálise. MÉTODOS: Sessenta e sete olhos de trinta e cinco pacientes foram avaliados no início, após 2 horas e após 4 horas do início de uma sessão de hemodiálise. A pressão intraocular foi avaliada usando o aparelho Tonopen. Pressões arteriais sistólica e diastólica foram aferidas usando esfigmomanômetro manual. A pressão de perfusão ocular foi estimada por meio do cálculo da diferença entre 2/3 da pressão arterial média e valores da pressão intraocular. Equações de estimação generalizada foram usadas para avaliar a diferença entre medidas repetidas usando correção apropriada para dependência entres olhos. RESULTADOS: Não houve diferença estatisticamente significativa na pressão de perfusão ocular, PIO (p=0,93) e na pressão arterial sistólica (p=0,92) nos três períodos medidos da hemodiálise (p=0,69). Mas, quando analisados valores extremos, alguns pacientes exibiram pressões diastólicas menores em todos os períodos aferidos. CONCLUSÃO: Nossos resultados não apontaram mudanças significativas na pressão de perfusão ocular e pressão intraocular durante a hemodiálise. No entanto, foi observado que alguns pacientes exibiram pressões diastólicas menores, o que pode ser um fator de prognóstico ruim para pacientes com glaucoma.Universidade Federal de São Paulo (UNIFESP) Ophthalmology DepartmentUniversidade Federal de São Paulo (UNIFESP) Division of NephrologyUNIFESP, Ophthalmology DepartmentUNIFESP, Division of NephrologySciELOConselho Brasileiro de OftalmologiaUniversidade Federal de São Paulo (UNIFESP)Barbosa, Carolina Pelegrini [UNIFESP]Stefanini, Francisco Rosa [UNIFESP]Penha, Fernando [UNIFESP]Góes, Miguel Ângelo [UNIFESP]Draibe, Sergio Antonio [UNIFESP]Canziani, Maria Eugênia Fernandes [UNIFESP]Paranhos Junior, Augusto [UNIFESP]2015-06-14T13:43:00Z2015-06-14T13:43:00Z2011-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion106-109application/pdfhttp://dx.doi.org/10.1590/S0004-27492011000200007Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 74, n. 2, p. 106-109, 2011.10.1590/S0004-27492011000200007S0004-27492011000200007.pdf0004-2749S0004-27492011000200007http://repositorio.unifesp.br/handle/11600/6390WOS:000292938700007engArquivos Brasileiros de Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-05T16:49:24Zoai:repositorio.unifesp.br/:11600/6390Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-05T16:49:24Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Intraocular pressure and ocular perfusion during hemodialysis Pressão intraocular e perfusão ocular durante hemodiálise |
title |
Intraocular pressure and ocular perfusion during hemodialysis |
spellingShingle |
Intraocular pressure and ocular perfusion during hemodialysis Barbosa, Carolina Pelegrini [UNIFESP] Renal dialysis Renal insufficiency, chronic Intraocular pressure Glaucoma Diálise renal Insuficiência renal crônica Pressão intraocular Glaucoma |
title_short |
Intraocular pressure and ocular perfusion during hemodialysis |
title_full |
Intraocular pressure and ocular perfusion during hemodialysis |
title_fullStr |
Intraocular pressure and ocular perfusion during hemodialysis |
title_full_unstemmed |
Intraocular pressure and ocular perfusion during hemodialysis |
title_sort |
Intraocular pressure and ocular perfusion during hemodialysis |
author |
Barbosa, Carolina Pelegrini [UNIFESP] |
author_facet |
Barbosa, Carolina Pelegrini [UNIFESP] Stefanini, Francisco Rosa [UNIFESP] Penha, Fernando [UNIFESP] Góes, Miguel Ângelo [UNIFESP] Draibe, Sergio Antonio [UNIFESP] Canziani, Maria Eugênia Fernandes [UNIFESP] Paranhos Junior, Augusto [UNIFESP] |
author_role |
author |
author2 |
Stefanini, Francisco Rosa [UNIFESP] Penha, Fernando [UNIFESP] Góes, Miguel Ângelo [UNIFESP] Draibe, Sergio Antonio [UNIFESP] Canziani, Maria Eugênia Fernandes [UNIFESP] Paranhos Junior, Augusto [UNIFESP] |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Federal de São Paulo (UNIFESP) |
dc.contributor.author.fl_str_mv |
Barbosa, Carolina Pelegrini [UNIFESP] Stefanini, Francisco Rosa [UNIFESP] Penha, Fernando [UNIFESP] Góes, Miguel Ângelo [UNIFESP] Draibe, Sergio Antonio [UNIFESP] Canziani, Maria Eugênia Fernandes [UNIFESP] Paranhos Junior, Augusto [UNIFESP] |
dc.subject.por.fl_str_mv |
Renal dialysis Renal insufficiency, chronic Intraocular pressure Glaucoma Diálise renal Insuficiência renal crônica Pressão intraocular Glaucoma |
topic |
Renal dialysis Renal insufficiency, chronic Intraocular pressure Glaucoma Diálise renal Insuficiência renal crônica Pressão intraocular Glaucoma |
description |
AIM: To evaluate the intraocular pressure and ocular perfusion pressure during a hemodialysis. METHODS: Sixty-seven eyes from thirty-five patients were evaluated at the beggining of hemodialysis, 2 hours and 4 hours after initiation. Intraocular pressure was evaluated using a Tonopen. Systolic and diastolic arterial pressures were measured with a manual sphygmomanometer. The ocular perfusion pressure was estimated by mea suring the difference between 2/3 of the mean arterial pressure and the intraocular pressure values. Generalized estimating equations were used to evaluate the difference between the repeated measurements using the appropriate correction for inter-eye dependency. RESULTS: There was no statistically significant difference in ocular perfusion pressure, in intraocular pressure (p=0.93) and in systolic arterial pressure (p=0.92) at the three time points (p=0.69). But, when analyzing the extreme values, some patients exhibited lower diastolic perfusion pressures at all time points. CONCLUSION: Our results did not support the view that significant changes in ocular perfusion pressure and intraocular pressure occur during hemodialysis session. However, we observed that some patients exhibited lower diastolic perfusion pressures, which could be a poor prognostic factor for glaucoma patients. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-04-01 2015-06-14T13:43:00Z 2015-06-14T13:43:00Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/S0004-27492011000200007 Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 74, n. 2, p. 106-109, 2011. 10.1590/S0004-27492011000200007 S0004-27492011000200007.pdf 0004-2749 S0004-27492011000200007 http://repositorio.unifesp.br/handle/11600/6390 WOS:000292938700007 |
url |
http://dx.doi.org/10.1590/S0004-27492011000200007 http://repositorio.unifesp.br/handle/11600/6390 |
identifier_str_mv |
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 74, n. 2, p. 106-109, 2011. 10.1590/S0004-27492011000200007 S0004-27492011000200007.pdf 0004-2749 S0004-27492011000200007 WOS:000292938700007 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
106-109 application/pdf |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1814268402207817728 |