Método computadorizado para medida da acuidade visual

Detalhes bibliográficos
Autor(a) principal: Arippol, Patrícia Katayama Kjaer [UNIFESP]
Data de Publicação: 2006
Outros Autores: Salomão, Solange Rios [UNIFESP], Belfort, Rubens Junior [UNIFESP]
Tipo de documento: Artigo
Idioma: por
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S0004-27492006000600021
http://repositorio.unifesp.br/handle/11600/3343
Resumo: PURPOSE: To elaborate and to validate a computerized test for visual acuity screening of school-age children. METHODS: We have created a computerized test for visual acuity assessment with optotypes arranged as those of printed logarithmic charts used in ophthalmic clinic. Ninety seven-year-old students, 8 normal adult volunteers and 10 patients from the Strabismus sector of the Federal University of São Paulo were evaluated by the same examiner and submitted to the visual acuity test through printed visual acuity logarithmic tumble E chart and the new computerized test at the same time. Written consent was obtained after clarification about the research project. RESULTS: Statistical analysis showed excellent correlation between the two methods (r>0.75) besides the slight trend of the computerized test to overestimate visual acuity when compared with the gold standard. Sensitivity of the computerized test was 100% (correctly identified 6 eyes with poor visual acuity) and specificity was 94%. CONCLUSION: The computerized test can be used as a new clinical tool for visual acuity screening of school-age children and it is fast, easy to perform and inexpensive, besides being more attractive for children. The method releases the examiner from the interpretation of the subject's answers and ensures the procedure's standardization even when more than one examiner performs the test. To better understand the effectiveness of this method for visual screening, one option would be to introduce it in elementary schools, after training the teachers to perform this test.
id UFSP_8e16d705a2bbf955e493052e00eedaba
oai_identifier_str oai:repositorio.unifesp.br/:11600/3343
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Método computadorizado para medida da acuidade visualA computerized method for visual acuity assessmentVisual acuityVision screeningSoftware validationVisionStudentsAcuidade visualSeleção visualValidação de programas de computadorVisãoEstudantesPURPOSE: To elaborate and to validate a computerized test for visual acuity screening of school-age children. METHODS: We have created a computerized test for visual acuity assessment with optotypes arranged as those of printed logarithmic charts used in ophthalmic clinic. Ninety seven-year-old students, 8 normal adult volunteers and 10 patients from the Strabismus sector of the Federal University of São Paulo were evaluated by the same examiner and submitted to the visual acuity test through printed visual acuity logarithmic tumble E chart and the new computerized test at the same time. Written consent was obtained after clarification about the research project. RESULTS: Statistical analysis showed excellent correlation between the two methods (r>0.75) besides the slight trend of the computerized test to overestimate visual acuity when compared with the gold standard. Sensitivity of the computerized test was 100% (correctly identified 6 eyes with poor visual acuity) and specificity was 94%. CONCLUSION: The computerized test can be used as a new clinical tool for visual acuity screening of school-age children and it is fast, easy to perform and inexpensive, besides being more attractive for children. The method releases the examiner from the interpretation of the subject's answers and ensures the procedure's standardization even when more than one examiner performs the test. To better understand the effectiveness of this method for visual screening, one option would be to introduce it in elementary schools, after training the teachers to perform this test.OBJETIVO: Elaborar e validar teste computadorizado para medida da acuidade visual de escolares. MÉTODOS: Foi elaborado teste computadorizado para determinação da acuidade visual utilizando os padrões das tabelas logarítmicas impressas adotadas na clínica oftalmológica. Foram avaliados 90 alunos da primeira série do ensino básico, oito estudantes do curso de Tecnologia Oftálmica da UNIFESP-EPM e 10 pacientes do ambulatório de Estrabismo do Departamento de Oftalmologia da UNIFESP-EPM. Todos os sujeitos foram avaliados pelo mesmo examinador e submetidos ao exame de acuidade visual monocular, pela tabela logarítmica de optotipos E impressa e do novo teste computadorizado no mesmo momento. Os participantes forneceram os seus consentimentos após esclarecimento. RESULTADOS: As análises estatísticas revelaram correlação excelente (r>0,75) entre os dois métodos, apesar da leve tendência apresentada pelo teste computadorizado em superestimar a acuidade visual quando comparado com o padrão-ouro. O teste computadorizado apresentou sensibilidade de 100% e especificidade de 94%. CONCLUSÕES: Os resultados obtidos nos permitem dizer que o teste computadorizado pode ser utilizado como novo recurso para triagem da qualidade visual dos escolares, por ser método rápido, de fácil aplicação, barato, automático e atrativo para as crianças. A automatização desvincula o aplicador da interpretação das respostas dadas pelo aluno testado, garante padronização do procedimento, que favorece as análises de acompanhamento e pode ser realizado por diferentes examinadores. Para melhor compreensão da efetividade do teste como instrumento de triagem visual, seria interessante instituí-lo nas escolas do curso básico, após treinamento dos professores para sua aplicação.Universidade Federal de São Paulo (UNIFESP)UNIFESP Departamento de OftalmologiaUNIFESP, Depto. de OftalmologiaSciELOConselho Brasileiro de OftalmologiaUniversidade Federal de São Paulo (UNIFESP)Arippol, Patrícia Katayama Kjaer [UNIFESP]Salomão, Solange Rios [UNIFESP]Belfort, Rubens Junior [UNIFESP]2015-06-14T13:36:31Z2015-06-14T13:36:31Z2006-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion907-914application/pdfhttp://dx.doi.org/10.1590/S0004-27492006000600021Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 69, n. 6, p. 907-914, 2006.10.1590/S0004-27492006000600021S0004-27492006000600021.pdf0004-2749S0004-27492006000600021http://repositorio.unifesp.br/handle/11600/3343porArquivos Brasileiros de Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-05T16:11:50Zoai:repositorio.unifesp.br/:11600/3343Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-05T16:11:50Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Método computadorizado para medida da acuidade visual
A computerized method for visual acuity assessment
title Método computadorizado para medida da acuidade visual
spellingShingle Método computadorizado para medida da acuidade visual
Arippol, Patrícia Katayama Kjaer [UNIFESP]
Visual acuity
Vision screening
Software validation
Vision
Students
Acuidade visual
Seleção visual
Validação de programas de computador
Visão
Estudantes
title_short Método computadorizado para medida da acuidade visual
title_full Método computadorizado para medida da acuidade visual
title_fullStr Método computadorizado para medida da acuidade visual
title_full_unstemmed Método computadorizado para medida da acuidade visual
title_sort Método computadorizado para medida da acuidade visual
author Arippol, Patrícia Katayama Kjaer [UNIFESP]
author_facet Arippol, Patrícia Katayama Kjaer [UNIFESP]
Salomão, Solange Rios [UNIFESP]
Belfort, Rubens Junior [UNIFESP]
author_role author
author2 Salomão, Solange Rios [UNIFESP]
Belfort, Rubens Junior [UNIFESP]
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
dc.contributor.author.fl_str_mv Arippol, Patrícia Katayama Kjaer [UNIFESP]
Salomão, Solange Rios [UNIFESP]
Belfort, Rubens Junior [UNIFESP]
dc.subject.por.fl_str_mv Visual acuity
Vision screening
Software validation
Vision
Students
Acuidade visual
Seleção visual
Validação de programas de computador
Visão
Estudantes
topic Visual acuity
Vision screening
Software validation
Vision
Students
Acuidade visual
Seleção visual
Validação de programas de computador
Visão
Estudantes
description PURPOSE: To elaborate and to validate a computerized test for visual acuity screening of school-age children. METHODS: We have created a computerized test for visual acuity assessment with optotypes arranged as those of printed logarithmic charts used in ophthalmic clinic. Ninety seven-year-old students, 8 normal adult volunteers and 10 patients from the Strabismus sector of the Federal University of São Paulo were evaluated by the same examiner and submitted to the visual acuity test through printed visual acuity logarithmic tumble E chart and the new computerized test at the same time. Written consent was obtained after clarification about the research project. RESULTS: Statistical analysis showed excellent correlation between the two methods (r>0.75) besides the slight trend of the computerized test to overestimate visual acuity when compared with the gold standard. Sensitivity of the computerized test was 100% (correctly identified 6 eyes with poor visual acuity) and specificity was 94%. CONCLUSION: The computerized test can be used as a new clinical tool for visual acuity screening of school-age children and it is fast, easy to perform and inexpensive, besides being more attractive for children. The method releases the examiner from the interpretation of the subject's answers and ensures the procedure's standardization even when more than one examiner performs the test. To better understand the effectiveness of this method for visual screening, one option would be to introduce it in elementary schools, after training the teachers to perform this test.
publishDate 2006
dc.date.none.fl_str_mv 2006-12-01
2015-06-14T13:36:31Z
2015-06-14T13:36:31Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0004-27492006000600021
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 69, n. 6, p. 907-914, 2006.
10.1590/S0004-27492006000600021
S0004-27492006000600021.pdf
0004-2749
S0004-27492006000600021
http://repositorio.unifesp.br/handle/11600/3343
url http://dx.doi.org/10.1590/S0004-27492006000600021
http://repositorio.unifesp.br/handle/11600/3343
identifier_str_mv Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 69, n. 6, p. 907-914, 2006.
10.1590/S0004-27492006000600021
S0004-27492006000600021.pdf
0004-2749
S0004-27492006000600021
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv Arquivos Brasileiros de Oftalmologia
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 907-914
application/pdf
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268344761581568