Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension

Detalhes bibliográficos
Autor(a) principal: Ventura, Angela C S [UNIFESP]
Data de Publicação: 2001
Outros Autores: Bohnke, M., Mojon, D. S.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1136/bjo.85.7.792
http://repositorio.unifesp.br/handle/11600/26586
Resumo: Background/aims-Recent studies have revealed patients with ocular hypertension to have thicker than normal central corneas and those with normal tension glaucoma to have thinner than normal ones, as determined by ultrasonic pachymetry. Since corneal thickness measurements and applanation tonometric estimates of intraocular pressure (IOP) correlate positively, monitoring of the former parameter have served as the basis for adjusting readings pertaining to the latter, with the consequence that many patients have had to be reclassified. With a view to validating these pachymetric studies, the central corneal thickness was determined in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension, as well as that of normal subjects, using optical low coherence reflectometry, which is a new and more precise method than ultrasonic pachymetry.Methods-34 patients with normal tension glaucoma, 20 with primary open angle glaucoma, 13 with pseudoexfoliation glaucoma, and 12 with ocular hypertension, together with 21 control subjects, were included in this observational, concurrent case-control study. One eye per individual was randomly selected for investigation. IOP was measured by Goldmann applanation tonometry and central corneal thickness by optical low coherence reflectometry.Results-Central corneal thickness was significantly higher (p less than or equal to0.001) in patients with ocular hypertension than in normal individuals or in subjects with either normal tension glaucoma, primary open angle glaucoma, or pseudoexfoliation glaucoma, there being no significant differences between the latter four groups. Patients with ocular hypertension were also significantly younger (p less than or equal to0.003) than those within any of the three glaucomatous groups.Conclusion-This study confirms that a significant number of patients with ocular hypertension have normal IOPs after the appropriate adjustments have been made for deviations from normal in their central corneal thickness. the accurate measurement of this latter parameter is important not only for individual patient care, in permitting more precise estimations of IOP, but also for clinical studies, in assuring a more reliable classification of subjects.
id UFSP_936c3b0989732a96680f442dc9d3b6c2
oai_identifier_str oai:repositorio.unifesp.br/:11600/26586
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertensionBackground/aims-Recent studies have revealed patients with ocular hypertension to have thicker than normal central corneas and those with normal tension glaucoma to have thinner than normal ones, as determined by ultrasonic pachymetry. Since corneal thickness measurements and applanation tonometric estimates of intraocular pressure (IOP) correlate positively, monitoring of the former parameter have served as the basis for adjusting readings pertaining to the latter, with the consequence that many patients have had to be reclassified. With a view to validating these pachymetric studies, the central corneal thickness was determined in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension, as well as that of normal subjects, using optical low coherence reflectometry, which is a new and more precise method than ultrasonic pachymetry.Methods-34 patients with normal tension glaucoma, 20 with primary open angle glaucoma, 13 with pseudoexfoliation glaucoma, and 12 with ocular hypertension, together with 21 control subjects, were included in this observational, concurrent case-control study. One eye per individual was randomly selected for investigation. IOP was measured by Goldmann applanation tonometry and central corneal thickness by optical low coherence reflectometry.Results-Central corneal thickness was significantly higher (p less than or equal to0.001) in patients with ocular hypertension than in normal individuals or in subjects with either normal tension glaucoma, primary open angle glaucoma, or pseudoexfoliation glaucoma, there being no significant differences between the latter four groups. Patients with ocular hypertension were also significantly younger (p less than or equal to0.003) than those within any of the three glaucomatous groups.Conclusion-This study confirms that a significant number of patients with ocular hypertension have normal IOPs after the appropriate adjustments have been made for deviations from normal in their central corneal thickness. the accurate measurement of this latter parameter is important not only for individual patient care, in permitting more precise estimations of IOP, but also for clinical studies, in assuring a more reliable classification of subjects.Univ Bern, Dept Ophthalmol, CH-3012 Bern, SwitzerlandKantonsspital St Gallen, Dept Strabismus & Neuroophthalmol, St Gallen, SwitzerlandWeb of ScienceBritish Med Journal Publ GroupUniv BernKantonsspital St GallenUniversidade Federal de São Paulo (UNIFESP)Ventura, Angela C S [UNIFESP]Bohnke, M.Mojon, D. S.2016-01-24T12:31:26Z2016-01-24T12:31:26Z2001-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion792-795http://dx.doi.org/10.1136/bjo.85.7.792British Journal of Ophthalmology. London: British Med Journal Publ Group, v. 85, n. 7, p. 792-795, 2001.10.1136/bjo.85.7.7920007-1161http://repositorio.unifesp.br/handle/11600/26586WOS:000169694600011engBritish Journal of Ophthalmologyinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2016-01-24T10:31:26Zoai:repositorio.unifesp.br/:11600/26586Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652016-01-24T10:31:26Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension
title Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension
spellingShingle Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension
Ventura, Angela C S [UNIFESP]
title_short Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension
title_full Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension
title_fullStr Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension
title_full_unstemmed Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension
title_sort Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension
author Ventura, Angela C S [UNIFESP]
author_facet Ventura, Angela C S [UNIFESP]
Bohnke, M.
Mojon, D. S.
author_role author
author2 Bohnke, M.
Mojon, D. S.
author2_role author
author
dc.contributor.none.fl_str_mv Univ Bern
Kantonsspital St Gallen
Universidade Federal de São Paulo (UNIFESP)
dc.contributor.author.fl_str_mv Ventura, Angela C S [UNIFESP]
Bohnke, M.
Mojon, D. S.
description Background/aims-Recent studies have revealed patients with ocular hypertension to have thicker than normal central corneas and those with normal tension glaucoma to have thinner than normal ones, as determined by ultrasonic pachymetry. Since corneal thickness measurements and applanation tonometric estimates of intraocular pressure (IOP) correlate positively, monitoring of the former parameter have served as the basis for adjusting readings pertaining to the latter, with the consequence that many patients have had to be reclassified. With a view to validating these pachymetric studies, the central corneal thickness was determined in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension, as well as that of normal subjects, using optical low coherence reflectometry, which is a new and more precise method than ultrasonic pachymetry.Methods-34 patients with normal tension glaucoma, 20 with primary open angle glaucoma, 13 with pseudoexfoliation glaucoma, and 12 with ocular hypertension, together with 21 control subjects, were included in this observational, concurrent case-control study. One eye per individual was randomly selected for investigation. IOP was measured by Goldmann applanation tonometry and central corneal thickness by optical low coherence reflectometry.Results-Central corneal thickness was significantly higher (p less than or equal to0.001) in patients with ocular hypertension than in normal individuals or in subjects with either normal tension glaucoma, primary open angle glaucoma, or pseudoexfoliation glaucoma, there being no significant differences between the latter four groups. Patients with ocular hypertension were also significantly younger (p less than or equal to0.003) than those within any of the three glaucomatous groups.Conclusion-This study confirms that a significant number of patients with ocular hypertension have normal IOPs after the appropriate adjustments have been made for deviations from normal in their central corneal thickness. the accurate measurement of this latter parameter is important not only for individual patient care, in permitting more precise estimations of IOP, but also for clinical studies, in assuring a more reliable classification of subjects.
publishDate 2001
dc.date.none.fl_str_mv 2001-07-01
2016-01-24T12:31:26Z
2016-01-24T12:31:26Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1136/bjo.85.7.792
British Journal of Ophthalmology. London: British Med Journal Publ Group, v. 85, n. 7, p. 792-795, 2001.
10.1136/bjo.85.7.792
0007-1161
http://repositorio.unifesp.br/handle/11600/26586
WOS:000169694600011
url http://dx.doi.org/10.1136/bjo.85.7.792
http://repositorio.unifesp.br/handle/11600/26586
identifier_str_mv British Journal of Ophthalmology. London: British Med Journal Publ Group, v. 85, n. 7, p. 792-795, 2001.
10.1136/bjo.85.7.792
0007-1161
WOS:000169694600011
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv British Journal of Ophthalmology
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 792-795
dc.publisher.none.fl_str_mv British Med Journal Publ Group
publisher.none.fl_str_mv British Med Journal Publ Group
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268377954254848