Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties

Detalhes bibliográficos
Autor(a) principal: Villas-bôas, Flávia Silva
Data de Publicação: 2009
Outros Autores: Doi, Larissa Morimoto [UNIFESP], Sousa, Aline Katia Siqueira [UNIFESP], Melo Jr., Luiz Alberto S. [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S0004-27492009000300004
http://repositorio.unifesp.br/handle/11600/5118
Resumo: PURPOSE: The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, central corneal thickness, mean central corneal curvature and ocular pulse amplitude. METHODS: A total of 12 controls (24 eyes) and 21 patients (38 eyes) with open-angle glaucoma were recruited. Intraocular pressure measured by Goldmann applanation tonometry, dynamic contour tonometry and corneal compensated non-contact tonometry, ocular pulse amplitude, central corneal curvature and thickness, corneal hysteresis, and resistance factor were obtained at intervals of 2 hours, between 9 AM and 5 PM. RESULTS: Intraocular pressure fluctuated significantly throughout the day in controls and glaucoma individuals with all tonometers (P<0.001). There was no statistically significant variation in mean corneal curvature (P=0.048 in controls; P=0.04 in glaucomatous) or hysteresis over time (P=0.12 in controls; P=0.36 in glaucomatous). The ocular pulse amplitude showed a significant diurnal fluctuation in both groups (P<0.001). There was a significant correlation between the intraocular pressure measured by dynamic contour tonometry and ocular pulse amplitude (P<0.001). CONCLUSION: There was significant intraocular pressure fluctuation over office hours on measurements performed by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry in normal and glaucoma individuals. Intraocular pressure varied independently of corneal hysteresis, central corneal thickness, and central curvature variation. However, there was significant correlation between ocular pulse amplitude and intraocular pressure measurements performed by dynamic contour tonometry.
id UFSP_98678f4e1672ad7cca90f724ccbbcaa6
oai_identifier_str oai:repositorio.unifesp.br/:11600/5118
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural propertiesCorrelação entre a variação diurna da pressão intraocular, amplitude de pulso e propriedades estruturais corneanasIntraocular pressureCorneaCorneal topographyGlaucomaTonometry, ocularCircadian rhythmPressão intraocularCórneaTopografia da córneaGlaucomaTonometria ocularRitmo circadianoPURPOSE: The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, central corneal thickness, mean central corneal curvature and ocular pulse amplitude. METHODS: A total of 12 controls (24 eyes) and 21 patients (38 eyes) with open-angle glaucoma were recruited. Intraocular pressure measured by Goldmann applanation tonometry, dynamic contour tonometry and corneal compensated non-contact tonometry, ocular pulse amplitude, central corneal curvature and thickness, corneal hysteresis, and resistance factor were obtained at intervals of 2 hours, between 9 AM and 5 PM. RESULTS: Intraocular pressure fluctuated significantly throughout the day in controls and glaucoma individuals with all tonometers (P<0.001). There was no statistically significant variation in mean corneal curvature (P=0.048 in controls; P=0.04 in glaucomatous) or hysteresis over time (P=0.12 in controls; P=0.36 in glaucomatous). The ocular pulse amplitude showed a significant diurnal fluctuation in both groups (P<0.001). There was a significant correlation between the intraocular pressure measured by dynamic contour tonometry and ocular pulse amplitude (P<0.001). CONCLUSION: There was significant intraocular pressure fluctuation over office hours on measurements performed by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry in normal and glaucoma individuals. Intraocular pressure varied independently of corneal hysteresis, central corneal thickness, and central curvature variation. However, there was significant correlation between ocular pulse amplitude and intraocular pressure measurements performed by dynamic contour tonometry.OBJETIVO: Avaliar a flutuação das medidas da pressão intraocular obtidas pela tonometria de aplanação de Goldmann, tonometria de contorno dinâmico e pela tonometria de não-contato com compensação corneana durante o período ambulatorial, em participantes com glaucoma e saudáveis. Esse estudo também correlacionou as flutuações da pressão intraocular com as flutuações da histerese corneana, espessura corneana central, média da curvatura corneana central e amplitude de pulso ocular. MÉTODOS: Um total de 12 controles (24 olhos) e 21 pacientes com glaucoma de ângulo aberto (38 olhos) foram selecionados. A pressão intraocular medida pela tonometria de aplanação de Goldmann, tonometria de contorno dinâmico e tonometria de não-contato com compensação corneana, amplitude de pulso ocular, a curvatura central e espessura corneanas, a histerese corneana e o fator de resistência foram medidos em intervalos de 2 horas, entre 9 AM e 5 PM. RESULTADOS: A pressão intraocular flutuou significativamente durante o dia em indivíduos controles e com glaucoma em todos os tonômetros (P<0,001). Não houve variação estatisticamente significante na média da curvatura corneana central (P=0,048 em controles; P=0,04 em glaucomatosos) ou na histerese no período pesquisado (P=0,12 em controles; P=0,36 em glaucomatosos). A amplitude de pulso ocular mostrou uma flutuação diurna significativa em ambos os grupos (P<0,001). Houve uma correlação significante entre a pressão intraocular medida pela tonometria de contorno dinâmico e a amplitude de pulso ocular (P<0,001). CONCLUSÃO: Houve uma flutuação significante da pressão intraocular ao longo do período ambulatorial nas medidas realizadas pela tonometria de aplanação de Goldmann, tonometria de contorno dinâmico, e tonometria de não-contato com compensação corneana em indivíduos normais e com glaucoma. A pressão intraocular variou independente da variação da histerese, espessura e curvatura central corneanas. Entretanto, houve correlação significante entre a amplitude de pulso ocular e as medidas de pressão intraocular realizadas pela tonometria de contorno dinâmico.Instituto Brasileiro de Oftalmologia e Prevenção à CegueiraUNIFESPUNIFESP Departamento de Oftalmologia Setor de GlaucomaUNIFESP, Depto. de Oftalmologia Setor de GlaucomaSciELOConselho Brasileiro de OftalmologiaInstituto Brasileiro de Oftalmologia e Prevenção à CegueiraUniversidade Federal de São Paulo (UNIFESP)Villas-bôas, Flávia SilvaDoi, Larissa Morimoto [UNIFESP]Sousa, Aline Katia Siqueira [UNIFESP]Melo Jr., Luiz Alberto S. [UNIFESP]2015-06-14T13:41:00Z2015-06-14T13:41:00Z2009-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion296-301application/pdfhttp://dx.doi.org/10.1590/S0004-27492009000300004Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 72, n. 3, p. 296-301, 2009.10.1590/S0004-27492009000300004S0004-27492009000300004.pdf0004-2749S0004-27492009000300004http://repositorio.unifesp.br/handle/11600/5118WOS:000274754000004engArquivos Brasileiros de Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-04T22:30:48Zoai:repositorio.unifesp.br/:11600/5118Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-04T22:30:48Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties
Correlação entre a variação diurna da pressão intraocular, amplitude de pulso e propriedades estruturais corneanas
title Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties
spellingShingle Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties
Villas-bôas, Flávia Silva
Intraocular pressure
Cornea
Corneal topography
Glaucoma
Tonometry, ocular
Circadian rhythm
Pressão intraocular
Córnea
Topografia da córnea
Glaucoma
Tonometria ocular
Ritmo circadiano
title_short Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties
title_full Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties
title_fullStr Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties
title_full_unstemmed Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties
title_sort Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties
author Villas-bôas, Flávia Silva
author_facet Villas-bôas, Flávia Silva
Doi, Larissa Morimoto [UNIFESP]
Sousa, Aline Katia Siqueira [UNIFESP]
Melo Jr., Luiz Alberto S. [UNIFESP]
author_role author
author2 Doi, Larissa Morimoto [UNIFESP]
Sousa, Aline Katia Siqueira [UNIFESP]
Melo Jr., Luiz Alberto S. [UNIFESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Instituto Brasileiro de Oftalmologia e Prevenção à Cegueira
Universidade Federal de São Paulo (UNIFESP)
dc.contributor.author.fl_str_mv Villas-bôas, Flávia Silva
Doi, Larissa Morimoto [UNIFESP]
Sousa, Aline Katia Siqueira [UNIFESP]
Melo Jr., Luiz Alberto S. [UNIFESP]
dc.subject.por.fl_str_mv Intraocular pressure
Cornea
Corneal topography
Glaucoma
Tonometry, ocular
Circadian rhythm
Pressão intraocular
Córnea
Topografia da córnea
Glaucoma
Tonometria ocular
Ritmo circadiano
topic Intraocular pressure
Cornea
Corneal topography
Glaucoma
Tonometry, ocular
Circadian rhythm
Pressão intraocular
Córnea
Topografia da córnea
Glaucoma
Tonometria ocular
Ritmo circadiano
description PURPOSE: The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, central corneal thickness, mean central corneal curvature and ocular pulse amplitude. METHODS: A total of 12 controls (24 eyes) and 21 patients (38 eyes) with open-angle glaucoma were recruited. Intraocular pressure measured by Goldmann applanation tonometry, dynamic contour tonometry and corneal compensated non-contact tonometry, ocular pulse amplitude, central corneal curvature and thickness, corneal hysteresis, and resistance factor were obtained at intervals of 2 hours, between 9 AM and 5 PM. RESULTS: Intraocular pressure fluctuated significantly throughout the day in controls and glaucoma individuals with all tonometers (P<0.001). There was no statistically significant variation in mean corneal curvature (P=0.048 in controls; P=0.04 in glaucomatous) or hysteresis over time (P=0.12 in controls; P=0.36 in glaucomatous). The ocular pulse amplitude showed a significant diurnal fluctuation in both groups (P<0.001). There was a significant correlation between the intraocular pressure measured by dynamic contour tonometry and ocular pulse amplitude (P<0.001). CONCLUSION: There was significant intraocular pressure fluctuation over office hours on measurements performed by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry in normal and glaucoma individuals. Intraocular pressure varied independently of corneal hysteresis, central corneal thickness, and central curvature variation. However, there was significant correlation between ocular pulse amplitude and intraocular pressure measurements performed by dynamic contour tonometry.
publishDate 2009
dc.date.none.fl_str_mv 2009-06-01
2015-06-14T13:41:00Z
2015-06-14T13:41:00Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0004-27492009000300004
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 72, n. 3, p. 296-301, 2009.
10.1590/S0004-27492009000300004
S0004-27492009000300004.pdf
0004-2749
S0004-27492009000300004
http://repositorio.unifesp.br/handle/11600/5118
WOS:000274754000004
url http://dx.doi.org/10.1590/S0004-27492009000300004
http://repositorio.unifesp.br/handle/11600/5118
identifier_str_mv Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 72, n. 3, p. 296-301, 2009.
10.1590/S0004-27492009000300004
S0004-27492009000300004.pdf
0004-2749
S0004-27492009000300004
WOS:000274754000004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Arquivos Brasileiros de Oftalmologia
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 296-301
application/pdf
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268387422896128