In vivo ultrathin Descemet stripping automated endothelial keratoplasty with a low-energy and high-frequency femtosecond laser

Detalhes bibliográficos
Autor(a) principal: Victor, Gustavo
Data de Publicação: 2014
Outros Autores: Nosé, Walton [UNIFESP], Sousa, Sidney Júlio de Faria e, Forseto, Adriana dos Santos [UNIFESP], Alves, Milton Ruiz
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.5935/0004-2749.20140031
http://repositorio.unifesp.br/handle/11600/8361
Resumo: This case report describes the production of an ultrathin endothelial donor corneal lamella using a femtosecond laser with low energy and a high frequency. In addition, we report its use in vivo in an eye with pseudophakic bullous keratopathy. The outcomes were observed 3 months after surgery in terms of the change in endothelial donor lamella and full cornea thickness (including pachymetric mapping), visual acuity, and endothelial cell count.
id UFSP_c77846612a69ec6039c7ed23d8890416
oai_identifier_str oai:repositorio.unifesp.br/:11600/8361
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling In vivo ultrathin Descemet stripping automated endothelial keratoplasty with a low-energy and high-frequency femtosecond laserIn vivo Descemet stripping automated endothelial keratoplasty ultrafina com laser de femtosegundo de baixa energia e alta frequênciaDescemet stripping endothelial keratoplastyLaser therapy, low-level/ methodsEndothelium cornealTomography, optical coherenceCase reportCeratoplastia endotelial com remoção da lâmina limitante posteriorTerapia a laser de baixa intensidadeEndotélio da córneaTomografia de coerência ópticaRelato de casoThis case report describes the production of an ultrathin endothelial donor corneal lamella using a femtosecond laser with low energy and a high frequency. In addition, we report its use in vivo in an eye with pseudophakic bullous keratopathy. The outcomes were observed 3 months after surgery in terms of the change in endothelial donor lamella and full cornea thickness (including pachymetric mapping), visual acuity, and endothelial cell count.Este relato de caso mostra a confecção de uma lamela corneana doadora endotelial ultrafina com o uso de um laser de femtosegundo de baixa energia e alta taxa de repetição, e sua utilização in vivo em um paciente com ceratopatia bolhosa do pseudofácico. O resultado final foi observado quanto a evolução da espessura da lamela endotelial doadora e de toda a córnea (incluindo mapa paquimétrico), da acuidade visual, e da contagem endotelial ao final de 3 meses de pós-operatório.Universidade de São Paulo School of Medicine Department of OphthalmologyUniversidade Federal de São Paulo (UNIFESP) Department of OphthalmologyUNIFESP, Department of OphthalmologySciELOFoundation for Research Support of the State of Sao Paulo (FAPESP)Conselho Brasileiro de OftalmologiaUniversidade de São Paulo (USP)Universidade Federal de São Paulo (UNIFESP)Victor, GustavoNosé, Walton [UNIFESP]Sousa, Sidney Júlio de Faria eForseto, Adriana dos Santos [UNIFESP]Alves, Milton Ruiz2015-06-14T13:47:04Z2015-06-14T13:47:04Z2014-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion122-124application/pdfhttp://dx.doi.org/10.5935/0004-2749.20140031Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 77, n. 2, p. 122-124, 2014.10.5935/0004-2749.20140031S0004-27492014000200122.pdf0004-27491678-2925S0004-27492014000200122http://repositorio.unifesp.br/handle/11600/8361WOS:000340485900015engArquivos Brasileiros de Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-05T03:25:32Zoai:repositorio.unifesp.br/:11600/8361Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-05T03:25:32Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv In vivo ultrathin Descemet stripping automated endothelial keratoplasty with a low-energy and high-frequency femtosecond laser
In vivo Descemet stripping automated endothelial keratoplasty ultrafina com laser de femtosegundo de baixa energia e alta frequência
title In vivo ultrathin Descemet stripping automated endothelial keratoplasty with a low-energy and high-frequency femtosecond laser
spellingShingle In vivo ultrathin Descemet stripping automated endothelial keratoplasty with a low-energy and high-frequency femtosecond laser
Victor, Gustavo
Descemet stripping endothelial keratoplasty
Laser therapy, low-level/ methods
Endothelium corneal
Tomography, optical coherence
Case report
Ceratoplastia endotelial com remoção da lâmina limitante posterior
Terapia a laser de baixa intensidade
Endotélio da córnea
Tomografia de coerência óptica
Relato de caso
title_short In vivo ultrathin Descemet stripping automated endothelial keratoplasty with a low-energy and high-frequency femtosecond laser
title_full In vivo ultrathin Descemet stripping automated endothelial keratoplasty with a low-energy and high-frequency femtosecond laser
title_fullStr In vivo ultrathin Descemet stripping automated endothelial keratoplasty with a low-energy and high-frequency femtosecond laser
title_full_unstemmed In vivo ultrathin Descemet stripping automated endothelial keratoplasty with a low-energy and high-frequency femtosecond laser
title_sort In vivo ultrathin Descemet stripping automated endothelial keratoplasty with a low-energy and high-frequency femtosecond laser
author Victor, Gustavo
author_facet Victor, Gustavo
Nosé, Walton [UNIFESP]
Sousa, Sidney Júlio de Faria e
Forseto, Adriana dos Santos [UNIFESP]
Alves, Milton Ruiz
author_role author
author2 Nosé, Walton [UNIFESP]
Sousa, Sidney Júlio de Faria e
Forseto, Adriana dos Santos [UNIFESP]
Alves, Milton Ruiz
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade de São Paulo (USP)
Universidade Federal de São Paulo (UNIFESP)
dc.contributor.author.fl_str_mv Victor, Gustavo
Nosé, Walton [UNIFESP]
Sousa, Sidney Júlio de Faria e
Forseto, Adriana dos Santos [UNIFESP]
Alves, Milton Ruiz
dc.subject.por.fl_str_mv Descemet stripping endothelial keratoplasty
Laser therapy, low-level/ methods
Endothelium corneal
Tomography, optical coherence
Case report
Ceratoplastia endotelial com remoção da lâmina limitante posterior
Terapia a laser de baixa intensidade
Endotélio da córnea
Tomografia de coerência óptica
Relato de caso
topic Descemet stripping endothelial keratoplasty
Laser therapy, low-level/ methods
Endothelium corneal
Tomography, optical coherence
Case report
Ceratoplastia endotelial com remoção da lâmina limitante posterior
Terapia a laser de baixa intensidade
Endotélio da córnea
Tomografia de coerência óptica
Relato de caso
description This case report describes the production of an ultrathin endothelial donor corneal lamella using a femtosecond laser with low energy and a high frequency. In addition, we report its use in vivo in an eye with pseudophakic bullous keratopathy. The outcomes were observed 3 months after surgery in terms of the change in endothelial donor lamella and full cornea thickness (including pachymetric mapping), visual acuity, and endothelial cell count.
publishDate 2014
dc.date.none.fl_str_mv 2014-04-01
2015-06-14T13:47:04Z
2015-06-14T13:47:04Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.5935/0004-2749.20140031
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 77, n. 2, p. 122-124, 2014.
10.5935/0004-2749.20140031
S0004-27492014000200122.pdf
0004-2749
1678-2925
S0004-27492014000200122
http://repositorio.unifesp.br/handle/11600/8361
WOS:000340485900015
url http://dx.doi.org/10.5935/0004-2749.20140031
http://repositorio.unifesp.br/handle/11600/8361
identifier_str_mv Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 77, n. 2, p. 122-124, 2014.
10.5935/0004-2749.20140031
S0004-27492014000200122.pdf
0004-2749
1678-2925
S0004-27492014000200122
WOS:000340485900015
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Arquivos Brasileiros de Oftalmologia
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 122-124
application/pdf
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268448226672640