Accuracy, sensitivity and specificity of fine needle aspiration biopsy in salivary gland tumours: A retrospective study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNIFESP |
Texto Completo: | http://dx.doi.org/10.4317/medoral.15.e32 http://repositorio.unifesp.br/handle/11600/32060 |
Resumo: | Objective: the aim of this study was to evaluate the diagnostic accuracy, sensitivity and specificity of fine needle aspiration biopsies (FNAB) of salivary gland tumours performed at the Erasto Gaertner Hospital over the course of a four year period. Study design: A retrospective study was carried out between 2001-2005 to review the cases of patients with salivary gland tumours who had undergone pre-operative FNAB and had been diagnosed during post-operative histopathology examination. Results: A total of 106 cases of salivary gland tumours were considered for this study, but 27 cases (25.5%) of the samples were considered unsatisfactory for analysis. the sensitivity, specificity and accuracy were calculated considering only the 79 benign and malignant cases in which FNAB provided sufficient samples for analysis. Based on these data, the value of sensitivity was 68.2% (15/22), specificity was 87.7% (50/57), accuracy was 82.3% (65/79), positive predictive value was 68.2% (15/22) and negative predictive value was 87.7% (50/57). Conclusions: Despite the high rate of inadequate samples obtained in the FNAB in this study, the technique offers high specificity, accuracy and acceptable sensitivity. |
id |
UFSP_e8eff78487540ea7cb25c02b03707e4f |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/32060 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Accuracy, sensitivity and specificity of fine needle aspiration biopsy in salivary gland tumours: A retrospective studySalivary gland tumourfine-needle aspirationcytologyObjective: the aim of this study was to evaluate the diagnostic accuracy, sensitivity and specificity of fine needle aspiration biopsies (FNAB) of salivary gland tumours performed at the Erasto Gaertner Hospital over the course of a four year period. Study design: A retrospective study was carried out between 2001-2005 to review the cases of patients with salivary gland tumours who had undergone pre-operative FNAB and had been diagnosed during post-operative histopathology examination. Results: A total of 106 cases of salivary gland tumours were considered for this study, but 27 cases (25.5%) of the samples were considered unsatisfactory for analysis. the sensitivity, specificity and accuracy were calculated considering only the 79 benign and malignant cases in which FNAB provided sufficient samples for analysis. Based on these data, the value of sensitivity was 68.2% (15/22), specificity was 87.7% (50/57), accuracy was 82.3% (65/79), positive predictive value was 68.2% (15/22) and negative predictive value was 87.7% (50/57). Conclusions: Despite the high rate of inadequate samples obtained in the FNAB in this study, the technique offers high specificity, accuracy and acceptable sensitivity.Erasto Gaertner Hosp, Dept Head & Neck Surg, BR-81520060 Curitiba, Parana, BrazilErasto Gaertner Hosp, Dept Oral & Maxillofacial Surg, BR-81520060 Curitiba, Parana, BrazilUniversidade Federal de São Paulo, São Paulo, BrazilUniv Fed Parana, BR-80060000 Curitiba, Parana, BrazilErasto Gaertner Hosp, Dept Pathol, BR-81520060 Curitiba, Parana, BrazilUniversidade Federal de São Paulo, EPM, São Paulo, BrazilWeb of ScienceMedicina Oral S LErasto Gaertner HospUniversidade Federal de São Paulo (UNIFESP)Univ Fed ParanaStramandinoli, Roberta TargaSassi, Laurindo Moacir [UNIFESP]Pedruzzi, Paola Andrea GalbiattiRamos, Gyl Henrique AlbrechtOliveira, Benedito Valdecir deOgata, Daniel CuryIoshii, Sergio Ossamu2016-01-24T13:59:03Z2016-01-24T13:59:03Z2010-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionE32-E37http://dx.doi.org/10.4317/medoral.15.e32Medicina Oral Patologia Oral Y Cirugia Bucal. Valencia: Medicina Oral S L, v. 15, n. 1, p. E32-E37, 2010.10.4317/medoral.15.e321698-4447http://repositorio.unifesp.br/handle/11600/32060WOS:000273829600008engMedicina Oral Patologia Oral Y Cirugia Bucalinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2022-07-08T10:54:12Zoai:repositorio.unifesp.br/:11600/32060Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652022-07-08T10:54:12Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Accuracy, sensitivity and specificity of fine needle aspiration biopsy in salivary gland tumours: A retrospective study |
title |
Accuracy, sensitivity and specificity of fine needle aspiration biopsy in salivary gland tumours: A retrospective study |
spellingShingle |
Accuracy, sensitivity and specificity of fine needle aspiration biopsy in salivary gland tumours: A retrospective study Stramandinoli, Roberta Targa Salivary gland tumour fine-needle aspiration cytology |
title_short |
Accuracy, sensitivity and specificity of fine needle aspiration biopsy in salivary gland tumours: A retrospective study |
title_full |
Accuracy, sensitivity and specificity of fine needle aspiration biopsy in salivary gland tumours: A retrospective study |
title_fullStr |
Accuracy, sensitivity and specificity of fine needle aspiration biopsy in salivary gland tumours: A retrospective study |
title_full_unstemmed |
Accuracy, sensitivity and specificity of fine needle aspiration biopsy in salivary gland tumours: A retrospective study |
title_sort |
Accuracy, sensitivity and specificity of fine needle aspiration biopsy in salivary gland tumours: A retrospective study |
author |
Stramandinoli, Roberta Targa |
author_facet |
Stramandinoli, Roberta Targa Sassi, Laurindo Moacir [UNIFESP] Pedruzzi, Paola Andrea Galbiatti Ramos, Gyl Henrique Albrecht Oliveira, Benedito Valdecir de Ogata, Daniel Cury Ioshii, Sergio Ossamu |
author_role |
author |
author2 |
Sassi, Laurindo Moacir [UNIFESP] Pedruzzi, Paola Andrea Galbiatti Ramos, Gyl Henrique Albrecht Oliveira, Benedito Valdecir de Ogata, Daniel Cury Ioshii, Sergio Ossamu |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Erasto Gaertner Hosp Universidade Federal de São Paulo (UNIFESP) Univ Fed Parana |
dc.contributor.author.fl_str_mv |
Stramandinoli, Roberta Targa Sassi, Laurindo Moacir [UNIFESP] Pedruzzi, Paola Andrea Galbiatti Ramos, Gyl Henrique Albrecht Oliveira, Benedito Valdecir de Ogata, Daniel Cury Ioshii, Sergio Ossamu |
dc.subject.por.fl_str_mv |
Salivary gland tumour fine-needle aspiration cytology |
topic |
Salivary gland tumour fine-needle aspiration cytology |
description |
Objective: the aim of this study was to evaluate the diagnostic accuracy, sensitivity and specificity of fine needle aspiration biopsies (FNAB) of salivary gland tumours performed at the Erasto Gaertner Hospital over the course of a four year period. Study design: A retrospective study was carried out between 2001-2005 to review the cases of patients with salivary gland tumours who had undergone pre-operative FNAB and had been diagnosed during post-operative histopathology examination. Results: A total of 106 cases of salivary gland tumours were considered for this study, but 27 cases (25.5%) of the samples were considered unsatisfactory for analysis. the sensitivity, specificity and accuracy were calculated considering only the 79 benign and malignant cases in which FNAB provided sufficient samples for analysis. Based on these data, the value of sensitivity was 68.2% (15/22), specificity was 87.7% (50/57), accuracy was 82.3% (65/79), positive predictive value was 68.2% (15/22) and negative predictive value was 87.7% (50/57). Conclusions: Despite the high rate of inadequate samples obtained in the FNAB in this study, the technique offers high specificity, accuracy and acceptable sensitivity. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-01-01 2016-01-24T13:59:03Z 2016-01-24T13:59:03Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.4317/medoral.15.e32 Medicina Oral Patologia Oral Y Cirugia Bucal. Valencia: Medicina Oral S L, v. 15, n. 1, p. E32-E37, 2010. 10.4317/medoral.15.e32 1698-4447 http://repositorio.unifesp.br/handle/11600/32060 WOS:000273829600008 |
url |
http://dx.doi.org/10.4317/medoral.15.e32 http://repositorio.unifesp.br/handle/11600/32060 |
identifier_str_mv |
Medicina Oral Patologia Oral Y Cirugia Bucal. Valencia: Medicina Oral S L, v. 15, n. 1, p. E32-E37, 2010. 10.4317/medoral.15.e32 1698-4447 WOS:000273829600008 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Medicina Oral Patologia Oral Y Cirugia Bucal |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
E32-E37 |
dc.publisher.none.fl_str_mv |
Medicina Oral S L |
publisher.none.fl_str_mv |
Medicina Oral S L |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1814268300138381312 |