Reliability analysis of radiographic methods for determination of posterolateral lumbossacral fusion

Detalhes bibliográficos
Autor(a) principal: Gotfryd, Alberto Ofenhejm
Data de Publicação: 2014
Outros Autores: Pomar, Felipe de Moraes, Carneiro Neto, Nicola Jorge, Franzin, Fernando José, Rodrigues, Luciano Miller Reis, Poletto, Patrícia Rios [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S1679-45082014AO2964
http://repositorio.unifesp.br/handle/11600/8324
Resumo: ObjectiveTo analyze intra and interobserver agreement of two radiographic methods for evaluation of posterolateral lumbar arthrodesis. MethodTwenty patients undergoing instrumented posterolateral fusion were evaluated by anteroposterior and dynamic lateral radiographs in maximal flexion and extension. The images were evaluated initially by 6 orthopedic surgeons, and after 8 weeks, reassessed by 4 of them, totaling 400 radiographic measurements. Intra and interobserver reliability were analyzed using the Kappa coefficient and Landis and Koch criteria. ResultIntra and interobserver agreement regarding anteroposterior radiographs were, respectively, 76 and 63%. On lateral views, these values were 78 and 84%, respectively. However, the Kappa analysis showed poor intra and interobserver agreement in most cases, regardless of the radiographic method used. ConclusionThere was poor intra and interobserver agreement in the evaluation of lumbosacral fusion by plain film in anteroposterior and dynamic lateral views, with no statistical superiority between the methods.
id UFSP_f70fed314bdb653fb865eeb391cfdd58
oai_identifier_str oai:repositorio.unifesp.br/:11600/8324
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Reliability analysis of radiographic methods for determination of posterolateral lumbossacral fusionAnálise da confiabilidade de métodos radiográficos para avaliação da artrodese posterolateral lombossacraSpine/radiographyLumbosacral region/radiographyArthrodesis/ radiographyBone screwsColuna vertebral/radiografiaRegião lombossacral/radiografiaArtrodese/radiografiaParafusos ósseosObjectiveTo analyze intra and interobserver agreement of two radiographic methods for evaluation of posterolateral lumbar arthrodesis. MethodTwenty patients undergoing instrumented posterolateral fusion were evaluated by anteroposterior and dynamic lateral radiographs in maximal flexion and extension. The images were evaluated initially by 6 orthopedic surgeons, and after 8 weeks, reassessed by 4 of them, totaling 400 radiographic measurements. Intra and interobserver reliability were analyzed using the Kappa coefficient and Landis and Koch criteria. ResultIntra and interobserver agreement regarding anteroposterior radiographs were, respectively, 76 and 63%. On lateral views, these values were 78 and 84%, respectively. However, the Kappa analysis showed poor intra and interobserver agreement in most cases, regardless of the radiographic method used. ConclusionThere was poor intra and interobserver agreement in the evaluation of lumbosacral fusion by plain film in anteroposterior and dynamic lateral views, with no statistical superiority between the methods.Objetivo Analisar a concordância intra e interobservador de dois métodos radiográficos para avaliação da artrodese lombar posterolateral. Métodos Foram submetidos à fusão posterolateral instrumentada 20 pacientes, avaliados por meio de radiografias anteroposteriores e laterais, em flexão e extensão máximas. As imagens foram avaliadas inicialmente por 6 médicos ortopedistas e, após 8 semanas, reavaliadas por 4 deles, totalizando 400 mensurações radiográficas. Foi realizada análise de confiabilidade intra e interobservador por meio do coeficiente Kappa e pelos critérios de Landis e Koch. Resultados A porcentagem de concordância intra e interobservadores para radiografias anteroposteriores foi, respectivamente, 76 e 63%. Na incidência radiográfica lateral, esses valores foram de 78 e 84%, respectivamente. Entretanto, a análise pelo método de Kappa mostrou concordância fraca e ruim intra e interobservadores para a maior parte dos casos, independentemente do método radiográfico utilizado. Conclusão observou-se fraca concordância intra e interobservadores na avaliação da fusão lombossacra por meio de radiografias simples, nas incidências anteroposterior e laterais dinâmicas, não havendo superioridade estatística entre os métodos estudados.Santa Casa da Misericórdia de SantosFaculdade de Medicina do ABCUniversidade Federal de São Paulo (UNIFESP)UNIFESP, ISS, Santos, BrazilSciELOInstituto Israelita de Ensino e Pesquisa Albert EinsteinSanta Casa da Misericórdia de SantosFaculdade de Medicina do ABCUniversidade Federal de São Paulo (UNIFESP)Gotfryd, Alberto OfenhejmPomar, Felipe de MoraesCarneiro Neto, Nicola JorgeFranzin, Fernando JoséRodrigues, Luciano Miller ReisPoletto, Patrícia Rios [UNIFESP]2015-06-14T13:47:02Z2015-06-14T13:47:02Z2014-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion198-203application/pdfhttp://dx.doi.org/10.1590/S1679-45082014AO2964Einstein (São Paulo). Instituto Israelita de Ensino e Pesquisa Albert Einstein, v. 12, n. 2, p. 198-203, 2014.10.1590/S1679-45082014AO2964S1679-45082014000200198.pdf1679-4508S1679-45082014000200198http://repositorio.unifesp.br/handle/11600/8324engEinstein (São Paulo)info:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-10-14T10:29:43Zoai:repositorio.unifesp.br/:11600/8324Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-10-14T10:29:43Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Reliability analysis of radiographic methods for determination of posterolateral lumbossacral fusion
Análise da confiabilidade de métodos radiográficos para avaliação da artrodese posterolateral lombossacra
title Reliability analysis of radiographic methods for determination of posterolateral lumbossacral fusion
spellingShingle Reliability analysis of radiographic methods for determination of posterolateral lumbossacral fusion
Gotfryd, Alberto Ofenhejm
Spine/radiography
Lumbosacral region/radiography
Arthrodesis/ radiography
Bone screws
Coluna vertebral/radiografia
Região lombossacral/radiografia
Artrodese/radiografia
Parafusos ósseos
title_short Reliability analysis of radiographic methods for determination of posterolateral lumbossacral fusion
title_full Reliability analysis of radiographic methods for determination of posterolateral lumbossacral fusion
title_fullStr Reliability analysis of radiographic methods for determination of posterolateral lumbossacral fusion
title_full_unstemmed Reliability analysis of radiographic methods for determination of posterolateral lumbossacral fusion
title_sort Reliability analysis of radiographic methods for determination of posterolateral lumbossacral fusion
author Gotfryd, Alberto Ofenhejm
author_facet Gotfryd, Alberto Ofenhejm
Pomar, Felipe de Moraes
Carneiro Neto, Nicola Jorge
Franzin, Fernando José
Rodrigues, Luciano Miller Reis
Poletto, Patrícia Rios [UNIFESP]
author_role author
author2 Pomar, Felipe de Moraes
Carneiro Neto, Nicola Jorge
Franzin, Fernando José
Rodrigues, Luciano Miller Reis
Poletto, Patrícia Rios [UNIFESP]
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Santa Casa da Misericórdia de Santos
Faculdade de Medicina do ABC
Universidade Federal de São Paulo (UNIFESP)
dc.contributor.author.fl_str_mv Gotfryd, Alberto Ofenhejm
Pomar, Felipe de Moraes
Carneiro Neto, Nicola Jorge
Franzin, Fernando José
Rodrigues, Luciano Miller Reis
Poletto, Patrícia Rios [UNIFESP]
dc.subject.por.fl_str_mv Spine/radiography
Lumbosacral region/radiography
Arthrodesis/ radiography
Bone screws
Coluna vertebral/radiografia
Região lombossacral/radiografia
Artrodese/radiografia
Parafusos ósseos
topic Spine/radiography
Lumbosacral region/radiography
Arthrodesis/ radiography
Bone screws
Coluna vertebral/radiografia
Região lombossacral/radiografia
Artrodese/radiografia
Parafusos ósseos
description ObjectiveTo analyze intra and interobserver agreement of two radiographic methods for evaluation of posterolateral lumbar arthrodesis. MethodTwenty patients undergoing instrumented posterolateral fusion were evaluated by anteroposterior and dynamic lateral radiographs in maximal flexion and extension. The images were evaluated initially by 6 orthopedic surgeons, and after 8 weeks, reassessed by 4 of them, totaling 400 radiographic measurements. Intra and interobserver reliability were analyzed using the Kappa coefficient and Landis and Koch criteria. ResultIntra and interobserver agreement regarding anteroposterior radiographs were, respectively, 76 and 63%. On lateral views, these values were 78 and 84%, respectively. However, the Kappa analysis showed poor intra and interobserver agreement in most cases, regardless of the radiographic method used. ConclusionThere was poor intra and interobserver agreement in the evaluation of lumbosacral fusion by plain film in anteroposterior and dynamic lateral views, with no statistical superiority between the methods.
publishDate 2014
dc.date.none.fl_str_mv 2014-04-01
2015-06-14T13:47:02Z
2015-06-14T13:47:02Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S1679-45082014AO2964
Einstein (São Paulo). Instituto Israelita de Ensino e Pesquisa Albert Einstein, v. 12, n. 2, p. 198-203, 2014.
10.1590/S1679-45082014AO2964
S1679-45082014000200198.pdf
1679-4508
S1679-45082014000200198
http://repositorio.unifesp.br/handle/11600/8324
url http://dx.doi.org/10.1590/S1679-45082014AO2964
http://repositorio.unifesp.br/handle/11600/8324
identifier_str_mv Einstein (São Paulo). Instituto Israelita de Ensino e Pesquisa Albert Einstein, v. 12, n. 2, p. 198-203, 2014.
10.1590/S1679-45082014AO2964
S1679-45082014000200198.pdf
1679-4508
S1679-45082014000200198
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Einstein (São Paulo)
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 198-203
application/pdf
dc.publisher.none.fl_str_mv Instituto Israelita de Ensino e Pesquisa Albert Einstein
publisher.none.fl_str_mv Instituto Israelita de Ensino e Pesquisa Albert Einstein
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268453056413696