Late outcome of right ventricular outflow tract repair using bicuspid pulmonary prosthesis in tetralogy of Fallot surgery repair: case report

Detalhes bibliográficos
Autor(a) principal: Maluf, Miguel Angel [UNIFESP]
Data de Publicação: 2009
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S0102-76382009000500021
http://repositorio.unifesp.br/handle/11600/45234
Resumo: We present a case of a 19 year-old female patient, with tetralogy of Fallot and hypoplastic pulmonary ring. Diagnosis was performed by echocardiography and cardiac catheterization. The surgical repair was performed at the age of 2 years old. A right ventricular outflow tract remodeling was performed using a porcine pulmonary bicuspid prosthesis. The patient presented a uneventful follow-up during 17 years. Postoperative assessment has shown: mild pulmonary insufficiency and mild pulmonary ventricle gradient, satisfactory right ventricular performance and prosthesis not presenting calcification. This is an option to correct the tetralogy of Fallot adopted by our Institution in the last two decades.
id UFSP_fa04c19ab85e545648a4ded188fed7d9
oai_identifier_str oai:repositorio.unifesp.br/:11600/45234
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Late outcome of right ventricular outflow tract repair using bicuspid pulmonary prosthesis in tetralogy of Fallot surgery repair: case reportResultado tardio da reconstrução da via de saída do ventrículo direito com prótese pulmonar bicúspide na correção da tetralogia de Fallot: relato de casoTetralogy of Fallot/surgeryHeart defects, congenital/surgeryTreatment outcomeWe present a case of a 19 year-old female patient, with tetralogy of Fallot and hypoplastic pulmonary ring. Diagnosis was performed by echocardiography and cardiac catheterization. The surgical repair was performed at the age of 2 years old. A right ventricular outflow tract remodeling was performed using a porcine pulmonary bicuspid prosthesis. The patient presented a uneventful follow-up during 17 years. Postoperative assessment has shown: mild pulmonary insufficiency and mild pulmonary ventricle gradient, satisfactory right ventricular performance and prosthesis not presenting calcification. This is an option to correct the tetralogy of Fallot adopted by our Institution in the last two decades.EPM, UNIFESP, Disciplina Cirurgia Cardiovasc, Sao Paulo, BrazilEPM, UNIFESP, Disciplina Cirurgia Cardiovasc, Sao Paulo, BrazilWeb of ScienceSoc Brasil Cirurgia CardiovascUniversidade Federal de São Paulo (UNIFESP)Maluf, Miguel Angel [UNIFESP]2018-06-18T11:35:40Z2018-06-18T11:35:40Z2009-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion574-577application/pdfhttp://dx.doi.org/10.1590/S0102-76382009000500021Revista Brasileira De Cirurgia Cardiovascular. Sao Paulo Sp: Soc Brasil Cirurgia Cardiovasc, v. 24, n. 4, p. 574-577, 2009.10.1590/S0102-76382009000500021S0102-76382009000500021.pdf0102-7638S0102-76382009000500021http://repositorio.unifesp.br/handle/11600/45234WOS:000273469200021engRevista Brasileira De Cirurgia Cardiovascularinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-02T06:06:37Zoai:repositorio.unifesp.br/:11600/45234Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-02T06:06:37Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Late outcome of right ventricular outflow tract repair using bicuspid pulmonary prosthesis in tetralogy of Fallot surgery repair: case report
Resultado tardio da reconstrução da via de saída do ventrículo direito com prótese pulmonar bicúspide na correção da tetralogia de Fallot: relato de caso
title Late outcome of right ventricular outflow tract repair using bicuspid pulmonary prosthesis in tetralogy of Fallot surgery repair: case report
spellingShingle Late outcome of right ventricular outflow tract repair using bicuspid pulmonary prosthesis in tetralogy of Fallot surgery repair: case report
Maluf, Miguel Angel [UNIFESP]
Tetralogy of Fallot/surgery
Heart defects, congenital/surgery
Treatment outcome
title_short Late outcome of right ventricular outflow tract repair using bicuspid pulmonary prosthesis in tetralogy of Fallot surgery repair: case report
title_full Late outcome of right ventricular outflow tract repair using bicuspid pulmonary prosthesis in tetralogy of Fallot surgery repair: case report
title_fullStr Late outcome of right ventricular outflow tract repair using bicuspid pulmonary prosthesis in tetralogy of Fallot surgery repair: case report
title_full_unstemmed Late outcome of right ventricular outflow tract repair using bicuspid pulmonary prosthesis in tetralogy of Fallot surgery repair: case report
title_sort Late outcome of right ventricular outflow tract repair using bicuspid pulmonary prosthesis in tetralogy of Fallot surgery repair: case report
author Maluf, Miguel Angel [UNIFESP]
author_facet Maluf, Miguel Angel [UNIFESP]
author_role author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
dc.contributor.author.fl_str_mv Maluf, Miguel Angel [UNIFESP]
dc.subject.por.fl_str_mv Tetralogy of Fallot/surgery
Heart defects, congenital/surgery
Treatment outcome
topic Tetralogy of Fallot/surgery
Heart defects, congenital/surgery
Treatment outcome
description We present a case of a 19 year-old female patient, with tetralogy of Fallot and hypoplastic pulmonary ring. Diagnosis was performed by echocardiography and cardiac catheterization. The surgical repair was performed at the age of 2 years old. A right ventricular outflow tract remodeling was performed using a porcine pulmonary bicuspid prosthesis. The patient presented a uneventful follow-up during 17 years. Postoperative assessment has shown: mild pulmonary insufficiency and mild pulmonary ventricle gradient, satisfactory right ventricular performance and prosthesis not presenting calcification. This is an option to correct the tetralogy of Fallot adopted by our Institution in the last two decades.
publishDate 2009
dc.date.none.fl_str_mv 2009-10-01
2018-06-18T11:35:40Z
2018-06-18T11:35:40Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0102-76382009000500021
Revista Brasileira De Cirurgia Cardiovascular. Sao Paulo Sp: Soc Brasil Cirurgia Cardiovasc, v. 24, n. 4, p. 574-577, 2009.
10.1590/S0102-76382009000500021
S0102-76382009000500021.pdf
0102-7638
S0102-76382009000500021
http://repositorio.unifesp.br/handle/11600/45234
WOS:000273469200021
url http://dx.doi.org/10.1590/S0102-76382009000500021
http://repositorio.unifesp.br/handle/11600/45234
identifier_str_mv Revista Brasileira De Cirurgia Cardiovascular. Sao Paulo Sp: Soc Brasil Cirurgia Cardiovasc, v. 24, n. 4, p. 574-577, 2009.
10.1590/S0102-76382009000500021
S0102-76382009000500021.pdf
0102-7638
S0102-76382009000500021
WOS:000273469200021
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Revista Brasileira De Cirurgia Cardiovascular
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 574-577
application/pdf
dc.publisher.none.fl_str_mv Soc Brasil Cirurgia Cardiovasc
publisher.none.fl_str_mv Soc Brasil Cirurgia Cardiovasc
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268288542179328