Spatio-temporal image correlation (STIC): a new technique for fetal heart evaluation

Detalhes bibliográficos
Autor(a) principal: Araujo Júnior, Edward [UNIFESP]
Data de Publicação: 2006
Outros Autores: Zanforlin Filho, Sebastiao Marques [UNIFESP], Pires, Claudio Rodrigues [UNIFESP], Guimarães Filho, Hélio Antonio [UNIFESP], Nardozza, Luciano Marcondes Machado [UNIFESP], Moron, Antonio Fernandes [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
por
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S0100-39842006000500014
http://repositorio.unifesp.br/handle/11600/3267
Resumo: Although congenital heart defect is the most frequent anomaly in newborns, its antenatal detection rate through conventional ultrasound remains low. 3D and 4D ultrasound technology was developed early in the nineties, bringing great benefits in obstetrics, especially in cases of dubious diagnosis at 2D ultrasound. The spatio-temporal image correlation (STIC) is a significant development in the field of 4D ultrasound. A software coupled with a Voluson 730 Expert equipment allows a volumetric acquisition of the fetal heart and its vascular connections. Volumetric analyses are performed in multiplanar and surface rendering modes or, alternatively in association with color Doppler. Major advantages are fast images acquisition and the possibility of a later analysis by fetal echocardiography specialists. Differently from 2D ultrasound, this technique may be applied for evaluating any congenital cardiopathy because of the increased number of frames acquired from a specific anatomical region. Main disadvantage is related to the necessity of fetal immobility. The higher diffusion of this method may improve prenatal detection of heart malformations since volumes data captured by a sonographer may be sent through the Internet for analysis by fetal echocardiography specialists.
id UFSP_fd04b449123a21977e2d85d81b8cf484
oai_identifier_str oai:repositorio.unifesp.br/:11600/3267
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Spatio-temporal image correlation (STIC): a new technique for fetal heart evaluationSpatio-temporal image correlation (STIC): nova técnica para avaliação do coração fetalAlthough congenital heart defect is the most frequent anomaly in newborns, its antenatal detection rate through conventional ultrasound remains low. 3D and 4D ultrasound technology was developed early in the nineties, bringing great benefits in obstetrics, especially in cases of dubious diagnosis at 2D ultrasound. The spatio-temporal image correlation (STIC) is a significant development in the field of 4D ultrasound. A software coupled with a Voluson 730 Expert equipment allows a volumetric acquisition of the fetal heart and its vascular connections. Volumetric analyses are performed in multiplanar and surface rendering modes or, alternatively in association with color Doppler. Major advantages are fast images acquisition and the possibility of a later analysis by fetal echocardiography specialists. Differently from 2D ultrasound, this technique may be applied for evaluating any congenital cardiopathy because of the increased number of frames acquired from a specific anatomical region. Main disadvantage is related to the necessity of fetal immobility. The higher diffusion of this method may improve prenatal detection of heart malformations since volumes data captured by a sonographer may be sent through the Internet for analysis by fetal echocardiography specialists.As malformações cardíacas são as mais freqüentes anomalias congênitas ao nascimento, entretanto, a sua detecção pré-natal pela ultra-sonografia convencional permanece baixa. As ultra-sonografias de terceira e quarta dimensões surgiram no início da década de 90, apresentando grandes aplicações em obstetrícia, principalmente nos casos de diagnósticos duvidosos à ultra-sonografia bidimensional. O spatio-temporal image correlation (STIC) representa grande avanço na área de ultra-som de quarta dimensão; constitui-se em um software acoplado ao aparelho Voluson 730 Expert, que permite a aquisição volumétrica do coração fetal e suas conexões vasculares. As análises volumétricas são realizadas nos modos multiplanar e de renderização, podendo-se também utilizar o Doppler. Apresenta, como grandes vantagens, a aquisição rápida e a possibilidade de análise posterior por especialistas em ecocardiografia fetal. Pode ser aplicada para a pesquisa de quaisquer cardiopatias congênitas, pois permite a aquisição de qualquer plano, diferentemente do ultra-som bidimensional. Sua principal desvantagem está relacionada aos movimentos fetais. A maior difusão do método pode permitir um aumento na detecção de malformações cardíacas, pois possibilita ao ultra-sonografista geral encaminhar, via Internet, os volumes para a análise por especialistas em ecocardiografia fetal.Universidade Federal de São Paulo (UNIFESP) Departamento de ObstetríciaUniversidade Federal de São Paulo (UNIFESP) Centro de Treinamento em Ultra-sonografia de São PauloUNIFESP, Depto. de ObstetríciaUNIFESP, Centro de Treinamento em Ultra-sonografia de São PauloSciELOUniversidade Federal de São Paulo (UNIFESP)Araujo Júnior, Edward [UNIFESP]Zanforlin Filho, Sebastiao Marques [UNIFESP]Pires, Claudio Rodrigues [UNIFESP]Guimarães Filho, Hélio Antonio [UNIFESP]Nardozza, Luciano Marcondes Machado [UNIFESP]Moron, Antonio Fernandes [UNIFESP]2015-06-14T13:36:27Z2015-06-14T13:36:27Z2006-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion373-377application/pdfapplication/pdfhttp://dx.doi.org/10.1590/S0100-3984200600050001410.1590/S0100-39842006000500014S0100-39842006000500014-en.pdfS0100-39842006000500014-pt.pdf1678-7099S0100-39842006000500014http://repositorio.unifesp.br/handle/11600/3267engporinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-07-27T17:24:29Zoai:repositorio.unifesp.br/:11600/3267Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-07-27T17:24:29Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Spatio-temporal image correlation (STIC): a new technique for fetal heart evaluation
Spatio-temporal image correlation (STIC): nova técnica para avaliação do coração fetal
title Spatio-temporal image correlation (STIC): a new technique for fetal heart evaluation
spellingShingle Spatio-temporal image correlation (STIC): a new technique for fetal heart evaluation
Araujo Júnior, Edward [UNIFESP]
title_short Spatio-temporal image correlation (STIC): a new technique for fetal heart evaluation
title_full Spatio-temporal image correlation (STIC): a new technique for fetal heart evaluation
title_fullStr Spatio-temporal image correlation (STIC): a new technique for fetal heart evaluation
title_full_unstemmed Spatio-temporal image correlation (STIC): a new technique for fetal heart evaluation
title_sort Spatio-temporal image correlation (STIC): a new technique for fetal heart evaluation
author Araujo Júnior, Edward [UNIFESP]
author_facet Araujo Júnior, Edward [UNIFESP]
Zanforlin Filho, Sebastiao Marques [UNIFESP]
Pires, Claudio Rodrigues [UNIFESP]
Guimarães Filho, Hélio Antonio [UNIFESP]
Nardozza, Luciano Marcondes Machado [UNIFESP]
Moron, Antonio Fernandes [UNIFESP]
author_role author
author2 Zanforlin Filho, Sebastiao Marques [UNIFESP]
Pires, Claudio Rodrigues [UNIFESP]
Guimarães Filho, Hélio Antonio [UNIFESP]
Nardozza, Luciano Marcondes Machado [UNIFESP]
Moron, Antonio Fernandes [UNIFESP]
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
dc.contributor.author.fl_str_mv Araujo Júnior, Edward [UNIFESP]
Zanforlin Filho, Sebastiao Marques [UNIFESP]
Pires, Claudio Rodrigues [UNIFESP]
Guimarães Filho, Hélio Antonio [UNIFESP]
Nardozza, Luciano Marcondes Machado [UNIFESP]
Moron, Antonio Fernandes [UNIFESP]
description Although congenital heart defect is the most frequent anomaly in newborns, its antenatal detection rate through conventional ultrasound remains low. 3D and 4D ultrasound technology was developed early in the nineties, bringing great benefits in obstetrics, especially in cases of dubious diagnosis at 2D ultrasound. The spatio-temporal image correlation (STIC) is a significant development in the field of 4D ultrasound. A software coupled with a Voluson 730 Expert equipment allows a volumetric acquisition of the fetal heart and its vascular connections. Volumetric analyses are performed in multiplanar and surface rendering modes or, alternatively in association with color Doppler. Major advantages are fast images acquisition and the possibility of a later analysis by fetal echocardiography specialists. Differently from 2D ultrasound, this technique may be applied for evaluating any congenital cardiopathy because of the increased number of frames acquired from a specific anatomical region. Main disadvantage is related to the necessity of fetal immobility. The higher diffusion of this method may improve prenatal detection of heart malformations since volumes data captured by a sonographer may be sent through the Internet for analysis by fetal echocardiography specialists.
publishDate 2006
dc.date.none.fl_str_mv 2006-10-01
2015-06-14T13:36:27Z
2015-06-14T13:36:27Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0100-39842006000500014
10.1590/S0100-39842006000500014
S0100-39842006000500014-en.pdf
S0100-39842006000500014-pt.pdf
1678-7099
S0100-39842006000500014
http://repositorio.unifesp.br/handle/11600/3267
url http://dx.doi.org/10.1590/S0100-39842006000500014
http://repositorio.unifesp.br/handle/11600/3267
identifier_str_mv 10.1590/S0100-39842006000500014
S0100-39842006000500014-en.pdf
S0100-39842006000500014-pt.pdf
1678-7099
S0100-39842006000500014
dc.language.iso.fl_str_mv eng
por
language eng
por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 373-377
application/pdf
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268321067958272