The Study of Attenuation Levels and the Comfort of Earplugs

Detalhes bibliográficos
Autor(a) principal: Samelli, Alessandra G.
Data de Publicação: 2018
Outros Autores: Gomes, Raquel F., Chammas, Tiago V., Silva, Barbara G., Moreira, Renata R., Fiorini, Ana Claudia [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: https://repositorio.unifesp.br/handle/11600/55554
http://www.noiseandhealth.org/article.asp?issn=1463-1741;year=2018;volume=20;issue=94;spage=112;epage=119;aulast=Samelli
Resumo: Introduction: This study aimed to analyze and compare four different types of earplugs, divided into premolded plugs and foam plug models, in relation to the level of attenuation, comfort, and the size of the external acoustic meatus (EAM) in an attempt to identify how these variables influence the choice of specific hearing protection devices (HPDs). Materials and Methods: A cross-sectional observational study was performed in a sample of 49 participants, oriented toward the ideal placement of four HPDs, two premolded and two foam plugs (3M (TM)). The procedures included otoscopy, EAM diameter measurement using an otometer, EAM volume measurement via an acoustic impedance test, and the obtainment of the bilateral personal attenuation rating (PAR) for each HPD using the E-A-Rfit (TM) Validation System (3M (TM)). The Bipolar Comfort Rating Scale (BCRS) instrument was applied twice for each individual: once after the evaluations with the premolded HPDs and again after the evaluations with the foam plug HPDs. Then, each participant was asked which was his/her favorite protector. Results: The volume of the EAM was not directly related to the diameter of the EAM. The attenuation did not interfere with the HPD preference, and the PAR of the foam plug was significantly higher regardless of the preferred HPD. Regarding the BCRS, the variables "Placement," "Complexity," and "Occlusion Effect" had higher scores for premolded HPDs and had a direct relationship with the type of preferred HPD. Conclusion: Attention to the use of HPDs should be personalized, taking into account the needs of each individual, considering not only the attenuation, but also the user's reported well-being.
id UFSP_fde1a7de76466469e5d703d84746b9be
oai_identifier_str oai:repositorio.unifesp.br:11600/55554
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Samelli, Alessandra G.Gomes, Raquel F.Chammas, Tiago V.Silva, Barbara G.Moreira, Renata R.Fiorini, Ana Claudia [UNIFESP]2020-07-20T16:30:51Z2020-07-20T16:30:51Z2018Noise & Health. Mumbai, v. 20, n. 94, p. 112-119, 2018.1463-1741https://repositorio.unifesp.br/handle/11600/55554http://www.noiseandhealth.org/article.asp?issn=1463-1741;year=2018;volume=20;issue=94;spage=112;epage=119;aulast=Samelli10.4103/nah.NAH_50_17WOS:000432732500006Introduction: This study aimed to analyze and compare four different types of earplugs, divided into premolded plugs and foam plug models, in relation to the level of attenuation, comfort, and the size of the external acoustic meatus (EAM) in an attempt to identify how these variables influence the choice of specific hearing protection devices (HPDs). Materials and Methods: A cross-sectional observational study was performed in a sample of 49 participants, oriented toward the ideal placement of four HPDs, two premolded and two foam plugs (3M (TM)). The procedures included otoscopy, EAM diameter measurement using an otometer, EAM volume measurement via an acoustic impedance test, and the obtainment of the bilateral personal attenuation rating (PAR) for each HPD using the E-A-Rfit (TM) Validation System (3M (TM)). The Bipolar Comfort Rating Scale (BCRS) instrument was applied twice for each individual: once after the evaluations with the premolded HPDs and again after the evaluations with the foam plug HPDs. Then, each participant was asked which was his/her favorite protector. Results: The volume of the EAM was not directly related to the diameter of the EAM. The attenuation did not interfere with the HPD preference, and the PAR of the foam plug was significantly higher regardless of the preferred HPD. Regarding the BCRS, the variables "Placement," "Complexity," and "Occlusion Effect" had higher scores for premolded HPDs and had a direct relationship with the type of preferred HPD. Conclusion: Attention to the use of HPDs should be personalized, taking into account the needs of each individual, considering not only the attenuation, but also the user's reported well-being.Univ Sao Paulo, Fac Med FMUSP, Sao Paulo, SP, BrazilUniv Sao Paulo, HU, Sao Paulo, SP, BrazilUniv Fed Sao Paulo UNIFESP, Sao Paulo, SP, BrazilPUC SP, Sao Paulo, SP, BrazilUniv Fed Sao Paulo UNIFESP, Sao Paulo, SP, BrazilWeb of Science112-119engMedknow Publications & Media Pvt LtdNoise & HealthAttenuationcomfortearplugsfit testhearing protection devicesThe Study of Attenuation Levels and the Comfort of Earplugsinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleMumbaiv. 2094info:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP11600/555542022-02-07 21:44:39.499metadata only accessoai:repositorio.unifesp.br:11600/55554Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestopendoar:34652022-02-08T00:44:39Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.en.fl_str_mv The Study of Attenuation Levels and the Comfort of Earplugs
title The Study of Attenuation Levels and the Comfort of Earplugs
spellingShingle The Study of Attenuation Levels and the Comfort of Earplugs
Samelli, Alessandra G.
Attenuation
comfort
earplugs
fit test
hearing protection devices
title_short The Study of Attenuation Levels and the Comfort of Earplugs
title_full The Study of Attenuation Levels and the Comfort of Earplugs
title_fullStr The Study of Attenuation Levels and the Comfort of Earplugs
title_full_unstemmed The Study of Attenuation Levels and the Comfort of Earplugs
title_sort The Study of Attenuation Levels and the Comfort of Earplugs
author Samelli, Alessandra G.
author_facet Samelli, Alessandra G.
Gomes, Raquel F.
Chammas, Tiago V.
Silva, Barbara G.
Moreira, Renata R.
Fiorini, Ana Claudia [UNIFESP]
author_role author
author2 Gomes, Raquel F.
Chammas, Tiago V.
Silva, Barbara G.
Moreira, Renata R.
Fiorini, Ana Claudia [UNIFESP]
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Samelli, Alessandra G.
Gomes, Raquel F.
Chammas, Tiago V.
Silva, Barbara G.
Moreira, Renata R.
Fiorini, Ana Claudia [UNIFESP]
dc.subject.eng.fl_str_mv Attenuation
comfort
earplugs
fit test
hearing protection devices
topic Attenuation
comfort
earplugs
fit test
hearing protection devices
description Introduction: This study aimed to analyze and compare four different types of earplugs, divided into premolded plugs and foam plug models, in relation to the level of attenuation, comfort, and the size of the external acoustic meatus (EAM) in an attempt to identify how these variables influence the choice of specific hearing protection devices (HPDs). Materials and Methods: A cross-sectional observational study was performed in a sample of 49 participants, oriented toward the ideal placement of four HPDs, two premolded and two foam plugs (3M (TM)). The procedures included otoscopy, EAM diameter measurement using an otometer, EAM volume measurement via an acoustic impedance test, and the obtainment of the bilateral personal attenuation rating (PAR) for each HPD using the E-A-Rfit (TM) Validation System (3M (TM)). The Bipolar Comfort Rating Scale (BCRS) instrument was applied twice for each individual: once after the evaluations with the premolded HPDs and again after the evaluations with the foam plug HPDs. Then, each participant was asked which was his/her favorite protector. Results: The volume of the EAM was not directly related to the diameter of the EAM. The attenuation did not interfere with the HPD preference, and the PAR of the foam plug was significantly higher regardless of the preferred HPD. Regarding the BCRS, the variables "Placement," "Complexity," and "Occlusion Effect" had higher scores for premolded HPDs and had a direct relationship with the type of preferred HPD. Conclusion: Attention to the use of HPDs should be personalized, taking into account the needs of each individual, considering not only the attenuation, but also the user's reported well-being.
publishDate 2018
dc.date.issued.fl_str_mv 2018
dc.date.accessioned.fl_str_mv 2020-07-20T16:30:51Z
dc.date.available.fl_str_mv 2020-07-20T16:30:51Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.citation.fl_str_mv Noise & Health. Mumbai, v. 20, n. 94, p. 112-119, 2018.
dc.identifier.uri.fl_str_mv https://repositorio.unifesp.br/handle/11600/55554
http://www.noiseandhealth.org/article.asp?issn=1463-1741;year=2018;volume=20;issue=94;spage=112;epage=119;aulast=Samelli
dc.identifier.issn.none.fl_str_mv 1463-1741
dc.identifier.doi.none.fl_str_mv 10.4103/nah.NAH_50_17
dc.identifier.wos.none.fl_str_mv WOS:000432732500006
identifier_str_mv Noise & Health. Mumbai, v. 20, n. 94, p. 112-119, 2018.
1463-1741
10.4103/nah.NAH_50_17
WOS:000432732500006
url https://repositorio.unifesp.br/handle/11600/55554
http://www.noiseandhealth.org/article.asp?issn=1463-1741;year=2018;volume=20;issue=94;spage=112;epage=119;aulast=Samelli
dc.language.iso.fl_str_mv eng
language eng
dc.relation.ispartof.none.fl_str_mv Noise & Health
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 112-119
dc.coverage.none.fl_str_mv Mumbai
dc.publisher.none.fl_str_mv Medknow Publications & Media Pvt Ltd
publisher.none.fl_str_mv Medknow Publications & Media Pvt Ltd
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv
_version_ 1802764113504370688