Effect of low temperature and room temperature on the depth of cure of bulk-fill composite resins

Detalhes bibliográficos
Autor(a) principal: Ferreira , Anna Flávia Esteves
Data de Publicação: 2023
Outros Autores: Silva, Ingrid Melo, Dietrich, Lia, Costa, Marcelo Dias Moreira de Assis, Andrade, Cláudia Maria de Oliveira, Martins, Victor da Mota
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Bioscience journal (Online)
Texto Completo: https://seer.ufu.br/index.php/biosciencejournal/article/view/63528
Resumo: The study analyzed the influence of temperature on the depth of cure of bulk-fill composite resins. Three discs (ISO 4049/2000) from each group were made, and four restorative materials were investigated: Opus Bulk-Fill Flow, Opus Bulk-Fill APS, Filtek™ One Bulk-Fill, and Filtek™ Bulk-Fill Flow. They were light-cured (Gnatus ± 1,200 mW/cm2) for 20 seconds, varying the temperature (23°C and 5°C) and simulating the use of the product both at room temperature and under refrigeration. The materials were inserted in aluminum matrices with 10 mm in depth and 4 mm in diameter. A clear film strip and a glass microscope slide were positioned at the top and bottom surfaces. The material was condensed and light-cured with the tip of the light source in close contact, for 20 seconds on the top surface. Immediately after irradiation, the samples were removed from the mold, and the uncured part was removed with a plastic spatula. The measurement was performed with a micrometer ± 0.1 mm, and the value was divided by 2. The data were analyzed with two-way ANOVA at a significance of 0.05. There was a statistical difference in the temperature between the results obtained in Opus Bulk-Fill APS (p <0.001) and Filtek™ Bulk-Fill Flow (p = 0.018) resins. For the temperature of 5°C, Filtek™ Bulk-Fill Flow showed a statistical difference compared to the other resins, while Opus Bulk-Fill Flow and Opus Bulk-Fill APS did not. For the temperature of 23°C, Filtek™ Bulk-Fill Flow maintained the statistical difference from the others, but Filtek™ One Bulk-Fill and Opus Bulk-Fill APS did not present statistical differences. Storing the Filtek™ Bulk-Fill Flow composite resin in the refrigerator caused a greater depth of cure than the other resins, and the depth of cure decreased at room temperature. As for Opus Bulk-Fill APS, the depth of cure decreased proportionally to the temperature decrease. The temperature may affect the depth of cure of some composite resins.
id UFU-14_e106378001e9b277764e1d1e209b1a8b
oai_identifier_str oai:ojs.www.seer.ufu.br:article/63528
network_acronym_str UFU-14
network_name_str Bioscience journal (Online)
repository_id_str
spelling Effect of low temperature and room temperature on the depth of cure of bulk-fill composite resinsComposite ResinsDepth of dental cureTemperature. Health SciencesThe study analyzed the influence of temperature on the depth of cure of bulk-fill composite resins. Three discs (ISO 4049/2000) from each group were made, and four restorative materials were investigated: Opus Bulk-Fill Flow, Opus Bulk-Fill APS, Filtek™ One Bulk-Fill, and Filtek™ Bulk-Fill Flow. They were light-cured (Gnatus ± 1,200 mW/cm2) for 20 seconds, varying the temperature (23°C and 5°C) and simulating the use of the product both at room temperature and under refrigeration. The materials were inserted in aluminum matrices with 10 mm in depth and 4 mm in diameter. A clear film strip and a glass microscope slide were positioned at the top and bottom surfaces. The material was condensed and light-cured with the tip of the light source in close contact, for 20 seconds on the top surface. Immediately after irradiation, the samples were removed from the mold, and the uncured part was removed with a plastic spatula. The measurement was performed with a micrometer ± 0.1 mm, and the value was divided by 2. The data were analyzed with two-way ANOVA at a significance of 0.05. There was a statistical difference in the temperature between the results obtained in Opus Bulk-Fill APS (p <0.001) and Filtek™ Bulk-Fill Flow (p = 0.018) resins. For the temperature of 5°C, Filtek™ Bulk-Fill Flow showed a statistical difference compared to the other resins, while Opus Bulk-Fill Flow and Opus Bulk-Fill APS did not. For the temperature of 23°C, Filtek™ Bulk-Fill Flow maintained the statistical difference from the others, but Filtek™ One Bulk-Fill and Opus Bulk-Fill APS did not present statistical differences. Storing the Filtek™ Bulk-Fill Flow composite resin in the refrigerator caused a greater depth of cure than the other resins, and the depth of cure decreased at room temperature. As for Opus Bulk-Fill APS, the depth of cure decreased proportionally to the temperature decrease. The temperature may affect the depth of cure of some composite resins.Universidade Federal de Uberlândia2023-01-20info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://seer.ufu.br/index.php/biosciencejournal/article/view/6352810.14393/BJ-v39n0a2023-63528Bioscience Journal ; Vol. 39 (2023): Continuous Publication; e39018Bioscience Journal ; v. 39 (2023): Continuous Publication; e390181981-3163reponame:Bioscience journal (Online)instname:Universidade Federal de Uberlândia (UFU)instacron:UFUenghttps://seer.ufu.br/index.php/biosciencejournal/article/view/63528/35495Brazil; Contemporary Copyright (c) 2023 Anna Flávia Esteves Ferreira , Ingrid Melo Silva, Lia Dietrich, Marcelo Dias Moreira de Assis Costa, Cláudia Maria de Oliveira Andrade, Victor da Mota Martinshttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessFerreira , Anna Flávia Esteves Silva, Ingrid Melo Dietrich, LiaCosta, Marcelo Dias Moreira de Assis Andrade, Cláudia Maria de OliveiraMartins, Victor da Mota2024-01-31T19:16:18Zoai:ojs.www.seer.ufu.br:article/63528Revistahttps://seer.ufu.br/index.php/biosciencejournalPUBhttps://seer.ufu.br/index.php/biosciencejournal/oaibiosciencej@ufu.br||1981-31631516-3725opendoar:2024-01-31T19:16:18Bioscience journal (Online) - Universidade Federal de Uberlândia (UFU)false
dc.title.none.fl_str_mv Effect of low temperature and room temperature on the depth of cure of bulk-fill composite resins
title Effect of low temperature and room temperature on the depth of cure of bulk-fill composite resins
spellingShingle Effect of low temperature and room temperature on the depth of cure of bulk-fill composite resins
Ferreira , Anna Flávia Esteves
Composite Resins
Depth of dental cure
Temperature.
Health Sciences
title_short Effect of low temperature and room temperature on the depth of cure of bulk-fill composite resins
title_full Effect of low temperature and room temperature on the depth of cure of bulk-fill composite resins
title_fullStr Effect of low temperature and room temperature on the depth of cure of bulk-fill composite resins
title_full_unstemmed Effect of low temperature and room temperature on the depth of cure of bulk-fill composite resins
title_sort Effect of low temperature and room temperature on the depth of cure of bulk-fill composite resins
author Ferreira , Anna Flávia Esteves
author_facet Ferreira , Anna Flávia Esteves
Silva, Ingrid Melo
Dietrich, Lia
Costa, Marcelo Dias Moreira de Assis
Andrade, Cláudia Maria de Oliveira
Martins, Victor da Mota
author_role author
author2 Silva, Ingrid Melo
Dietrich, Lia
Costa, Marcelo Dias Moreira de Assis
Andrade, Cláudia Maria de Oliveira
Martins, Victor da Mota
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Ferreira , Anna Flávia Esteves
Silva, Ingrid Melo
Dietrich, Lia
Costa, Marcelo Dias Moreira de Assis
Andrade, Cláudia Maria de Oliveira
Martins, Victor da Mota
dc.subject.por.fl_str_mv Composite Resins
Depth of dental cure
Temperature.
Health Sciences
topic Composite Resins
Depth of dental cure
Temperature.
Health Sciences
description The study analyzed the influence of temperature on the depth of cure of bulk-fill composite resins. Three discs (ISO 4049/2000) from each group were made, and four restorative materials were investigated: Opus Bulk-Fill Flow, Opus Bulk-Fill APS, Filtek™ One Bulk-Fill, and Filtek™ Bulk-Fill Flow. They were light-cured (Gnatus ± 1,200 mW/cm2) for 20 seconds, varying the temperature (23°C and 5°C) and simulating the use of the product both at room temperature and under refrigeration. The materials were inserted in aluminum matrices with 10 mm in depth and 4 mm in diameter. A clear film strip and a glass microscope slide were positioned at the top and bottom surfaces. The material was condensed and light-cured with the tip of the light source in close contact, for 20 seconds on the top surface. Immediately after irradiation, the samples were removed from the mold, and the uncured part was removed with a plastic spatula. The measurement was performed with a micrometer ± 0.1 mm, and the value was divided by 2. The data were analyzed with two-way ANOVA at a significance of 0.05. There was a statistical difference in the temperature between the results obtained in Opus Bulk-Fill APS (p <0.001) and Filtek™ Bulk-Fill Flow (p = 0.018) resins. For the temperature of 5°C, Filtek™ Bulk-Fill Flow showed a statistical difference compared to the other resins, while Opus Bulk-Fill Flow and Opus Bulk-Fill APS did not. For the temperature of 23°C, Filtek™ Bulk-Fill Flow maintained the statistical difference from the others, but Filtek™ One Bulk-Fill and Opus Bulk-Fill APS did not present statistical differences. Storing the Filtek™ Bulk-Fill Flow composite resin in the refrigerator caused a greater depth of cure than the other resins, and the depth of cure decreased at room temperature. As for Opus Bulk-Fill APS, the depth of cure decreased proportionally to the temperature decrease. The temperature may affect the depth of cure of some composite resins.
publishDate 2023
dc.date.none.fl_str_mv 2023-01-20
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://seer.ufu.br/index.php/biosciencejournal/article/view/63528
10.14393/BJ-v39n0a2023-63528
url https://seer.ufu.br/index.php/biosciencejournal/article/view/63528
identifier_str_mv 10.14393/BJ-v39n0a2023-63528
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://seer.ufu.br/index.php/biosciencejournal/article/view/63528/35495
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv Brazil; Contemporary
dc.publisher.none.fl_str_mv Universidade Federal de Uberlândia
publisher.none.fl_str_mv Universidade Federal de Uberlândia
dc.source.none.fl_str_mv Bioscience Journal ; Vol. 39 (2023): Continuous Publication; e39018
Bioscience Journal ; v. 39 (2023): Continuous Publication; e39018
1981-3163
reponame:Bioscience journal (Online)
instname:Universidade Federal de Uberlândia (UFU)
instacron:UFU
instname_str Universidade Federal de Uberlândia (UFU)
instacron_str UFU
institution UFU
reponame_str Bioscience journal (Online)
collection Bioscience journal (Online)
repository.name.fl_str_mv Bioscience journal (Online) - Universidade Federal de Uberlândia (UFU)
repository.mail.fl_str_mv biosciencej@ufu.br||
_version_ 1797069065208987648