Estudo comparativo de diferentes fixações na técnica de mandibulalotomia
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFU |
Texto Completo: | https://repositorio.ufu.br/handle/123456789/14826 |
Resumo: | The number of tumors in the oral cavity is increasing significantly, mainly, due to the use of tobacco. In general, resection is the treatment for these tumors. This process is made through the access to the oral cavity using the mandibulotomy technique. For that, different cuts can be made in the mandible, in function of tumor position and patient condition. The cuts fixation, in general, are made using miniplates and titanium screws or steel wires. In this aspect, many clinical doubts exist, under the biomechanics perspective, on which is the best surgical procedure would be. This work aims to evaluate two types of cuts in a mandible, midline and paramidline, using different fixation sets with miniplates. Simplified finite element models were used to verify which was the best configuration through analysis of the stability level and stress gradient. At the same time, a human jaw photoelastic model was used, where two types of cuts were analyzed: midline and paramidline, with two types of knotting for wires, parallel and opposite. The critical stress levels were evaluated for different cross sections. Additionally, a visual inspection of relative displacement was made between the cross sectional. It was observed that the number of bolts does not influence the stability when the same number of miniplates is used. Using only one miniplate, the medium cut presents better stability than the paramidline cut. Using two miniplates in the setting, despite the small difference, the paramidline presents better stability, while the best configuration is that with two miniplates and six screws. A significant increase in the obtained stress level was observed with two miniplates and six screws fastened. |
id |
UFU_17fb8b6dc5f669c57efd70c7eee839eb |
---|---|
oai_identifier_str |
oai:repositorio.ufu.br:123456789/14826 |
network_acronym_str |
UFU |
network_name_str |
Repositório Institucional da UFU |
repository_id_str |
|
spelling |
Estudo comparativo de diferentes fixações na técnica de mandibulalotomiaComparative study of different fixation in the mandibulotomy techniqueMandibulotomiaAnálise de tensõesMiniplacasBiomecânicaMandibulotomyStress analysisFinite element methodPhotoelasticityMiniplatesCNPQ::ENGENHARIAS::ENGENHARIA MECANICAThe number of tumors in the oral cavity is increasing significantly, mainly, due to the use of tobacco. In general, resection is the treatment for these tumors. This process is made through the access to the oral cavity using the mandibulotomy technique. For that, different cuts can be made in the mandible, in function of tumor position and patient condition. The cuts fixation, in general, are made using miniplates and titanium screws or steel wires. In this aspect, many clinical doubts exist, under the biomechanics perspective, on which is the best surgical procedure would be. This work aims to evaluate two types of cuts in a mandible, midline and paramidline, using different fixation sets with miniplates. Simplified finite element models were used to verify which was the best configuration through analysis of the stability level and stress gradient. At the same time, a human jaw photoelastic model was used, where two types of cuts were analyzed: midline and paramidline, with two types of knotting for wires, parallel and opposite. The critical stress levels were evaluated for different cross sections. Additionally, a visual inspection of relative displacement was made between the cross sectional. It was observed that the number of bolts does not influence the stability when the same number of miniplates is used. Using only one miniplate, the medium cut presents better stability than the paramidline cut. Using two miniplates in the setting, despite the small difference, the paramidline presents better stability, while the best configuration is that with two miniplates and six screws. A significant increase in the obtained stress level was observed with two miniplates and six screws fastened.Fundação de Amparo a Pesquisa do Estado de Minas GeraisMestre em Engenharia MecânicaO número de tumores na cavidade oral vem aumentando significativamente, principalmente, devido ao uso do fumo. Na maioria dos casos, a forma de tratamento destes tumores é a sua ressecção. Em várias situações isto é feito através do acesso oral utilizando a técnica de mandibulotomia. Para isto, podem ser feitos diferentes tipos de corte na mandíbula em função da localização do tumor e da condição do paciente. A fixação destes cortes, em geral, é feita através de miniplacas e parafusos de titânio ou fios de aço. Neste aspecto, existem muitas dúvidas clínicas, do ponto de vista biomecânico, sobre qual o melhor procedimento cirúrgico. O objetivo deste trabalho foi avaliar dois tipos de corte na mandíbula, mediano e paramediano, usando diferentes conjuntos de fixação com miniplacas. Modelos de elementos finitos simplificados foram utilizados para verificar qual a melhor configuração através dos níveis de estabilidade e gradiente de tensões. Paralelamente, foi utilizado um modelo fotoelástico de uma mandíbula humana, onde foram analisados dois tipos de cortes: mediano e paramediano com dois tipos de amarração por fios, paralela e cruzada. Através dos níveis de tensão gerados em cada tipo de corte foram avaliados os pontos críticos dos modelos. Paralelamente, foi feita uma inspeção visual sobre os efeitos do deslocamento relativo entre as faces dos cortes. Foi observado que o número de pinos não influencia na estabilidade quando for utilizada a mesma quantidade de miniplacas. Utilizando apenas uma miniplaca, o corte mediano apresenta melhor estabilidade que o corte paramediano. Utilizando duas miniplacas na fixação, apesar da pequena diferença, o paramediano apresenta estabilidade um pouco melhor, sendo a melhor configuração com duas miniplacas e 6 parafusos. Observou-se um aumento significativo no nível das tensões nos modelos fixados com duas miniplacas e seis parafusos.Universidade Federal de UberlândiaBRPrograma de Pós-graduação em Engenharia MecânicaEngenhariasUFUSilva, Sindeval José dahttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4777762U4Araújo, Cleudmar Amaral dehttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4782336A0Oliveira, Sônia Aparecida Goulart dehttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4785944D1Casas, Estevam Barbosa de Lashttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4787963T4Araujo, Thiago Caixeta2016-06-22T18:40:03Z2009-05-182016-06-22T18:40:03Z2008-03-07info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfapplication/pdfARAUJO, Thiago Caixeta. Comparative study of different fixation in the mandibulotomy technique. 2008. 110 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Uberlândia, Uberlândia, 2008.https://repositorio.ufu.br/handle/123456789/14826porinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFUinstname:Universidade Federal de Uberlândia (UFU)instacron:UFU2016-06-23T07:06:05Zoai:repositorio.ufu.br:123456789/14826Repositório InstitucionalONGhttp://repositorio.ufu.br/oai/requestdiinf@dirbi.ufu.bropendoar:2016-06-23T07:06:05Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)false |
dc.title.none.fl_str_mv |
Estudo comparativo de diferentes fixações na técnica de mandibulalotomia Comparative study of different fixation in the mandibulotomy technique |
title |
Estudo comparativo de diferentes fixações na técnica de mandibulalotomia |
spellingShingle |
Estudo comparativo de diferentes fixações na técnica de mandibulalotomia Araujo, Thiago Caixeta Mandibulotomia Análise de tensões Miniplacas Biomecânica Mandibulotomy Stress analysis Finite element method Photoelasticity Miniplates CNPQ::ENGENHARIAS::ENGENHARIA MECANICA |
title_short |
Estudo comparativo de diferentes fixações na técnica de mandibulalotomia |
title_full |
Estudo comparativo de diferentes fixações na técnica de mandibulalotomia |
title_fullStr |
Estudo comparativo de diferentes fixações na técnica de mandibulalotomia |
title_full_unstemmed |
Estudo comparativo de diferentes fixações na técnica de mandibulalotomia |
title_sort |
Estudo comparativo de diferentes fixações na técnica de mandibulalotomia |
author |
Araujo, Thiago Caixeta |
author_facet |
Araujo, Thiago Caixeta |
author_role |
author |
dc.contributor.none.fl_str_mv |
Silva, Sindeval José da http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4777762U4 Araújo, Cleudmar Amaral de http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4782336A0 Oliveira, Sônia Aparecida Goulart de http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4785944D1 Casas, Estevam Barbosa de Las http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4787963T4 |
dc.contributor.author.fl_str_mv |
Araujo, Thiago Caixeta |
dc.subject.por.fl_str_mv |
Mandibulotomia Análise de tensões Miniplacas Biomecânica Mandibulotomy Stress analysis Finite element method Photoelasticity Miniplates CNPQ::ENGENHARIAS::ENGENHARIA MECANICA |
topic |
Mandibulotomia Análise de tensões Miniplacas Biomecânica Mandibulotomy Stress analysis Finite element method Photoelasticity Miniplates CNPQ::ENGENHARIAS::ENGENHARIA MECANICA |
description |
The number of tumors in the oral cavity is increasing significantly, mainly, due to the use of tobacco. In general, resection is the treatment for these tumors. This process is made through the access to the oral cavity using the mandibulotomy technique. For that, different cuts can be made in the mandible, in function of tumor position and patient condition. The cuts fixation, in general, are made using miniplates and titanium screws or steel wires. In this aspect, many clinical doubts exist, under the biomechanics perspective, on which is the best surgical procedure would be. This work aims to evaluate two types of cuts in a mandible, midline and paramidline, using different fixation sets with miniplates. Simplified finite element models were used to verify which was the best configuration through analysis of the stability level and stress gradient. At the same time, a human jaw photoelastic model was used, where two types of cuts were analyzed: midline and paramidline, with two types of knotting for wires, parallel and opposite. The critical stress levels were evaluated for different cross sections. Additionally, a visual inspection of relative displacement was made between the cross sectional. It was observed that the number of bolts does not influence the stability when the same number of miniplates is used. Using only one miniplate, the medium cut presents better stability than the paramidline cut. Using two miniplates in the setting, despite the small difference, the paramidline presents better stability, while the best configuration is that with two miniplates and six screws. A significant increase in the obtained stress level was observed with two miniplates and six screws fastened. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-03-07 2009-05-18 2016-06-22T18:40:03Z 2016-06-22T18:40:03Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
ARAUJO, Thiago Caixeta. Comparative study of different fixation in the mandibulotomy technique. 2008. 110 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Uberlândia, Uberlândia, 2008. https://repositorio.ufu.br/handle/123456789/14826 |
identifier_str_mv |
ARAUJO, Thiago Caixeta. Comparative study of different fixation in the mandibulotomy technique. 2008. 110 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Uberlândia, Uberlândia, 2008. |
url |
https://repositorio.ufu.br/handle/123456789/14826 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Uberlândia BR Programa de Pós-graduação em Engenharia Mecânica Engenharias UFU |
publisher.none.fl_str_mv |
Universidade Federal de Uberlândia BR Programa de Pós-graduação em Engenharia Mecânica Engenharias UFU |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFU instname:Universidade Federal de Uberlândia (UFU) instacron:UFU |
instname_str |
Universidade Federal de Uberlândia (UFU) |
instacron_str |
UFU |
institution |
UFU |
reponame_str |
Repositório Institucional da UFU |
collection |
Repositório Institucional da UFU |
repository.name.fl_str_mv |
Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU) |
repository.mail.fl_str_mv |
diinf@dirbi.ufu.br |
_version_ |
1805569582390312960 |