Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporose
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFU |
Texto Completo: | https://repositorio.ufu.br/handle/123456789/20666 http://dx.doi.org/10.14393/ufu.di.2018.41 |
Resumo: | The present study aims to evaluate the effect of the factor Operator on Cobb angle values obtained on X-ray images of patients who were diagnosed with scoliosis, kyphosis and osteoporosis, as well as to propose procedures to evaluate the measurement uncertainty of this measurand taking into account each measuring system used. For this, the Cobb angle was measured by three Operators in analog, digital and computerized images in the diagnosis of scoliosis and kyphosis. Two measurement systems were used to carry out the measurements, the analog transponder (analogue images) and the Kinovea software (digital and computerized images). For the diagnosis of osteoporosis, measurements were made only on digital images using Prodigy Lunar software - BMD and Kinovea. The analysis of the results was carried out by applying analysis of variance (ANOVA) using Statistica R. The measurement uncertainty was estimated following the recommendations of the GUM method proposed in JCGM 101. The results indicated that Operator 1 "Experienced" presented the best repeatability of the results and consequently the lower uncertainty. The images with greater curvature in the vertebral column presented worse repeatability of the average values of Cobb angle and consequently higher values of expanded uncertainty, which demonstrates the difficulty to identify the vertebrae limits by the Operators when the angles are larger. The expanded uncertainty values (95%) associated with the Cobb angle for diagnosis of osteoporosis may be of the same order as the value of the measurand in some cases. |
id |
UFU_218e2ae0894fa18e4acd8347347acd8e |
---|---|
oai_identifier_str |
oai:repositorio.ufu.br:123456789/20666 |
network_acronym_str |
UFU |
network_name_str |
Repositório Institucional da UFU |
repository_id_str |
|
spelling |
Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporoseEvauation of factors affecting the analysis of X-ray images for diagnosis of kyphosis, escoliosis and osteoporosisEscolioseCifoseOsteoporoseRaio-XAnovaScoliosisKyphosisOsteoporosisX-ray imagesAnovaCNPQ::ENGENHARIASThe present study aims to evaluate the effect of the factor Operator on Cobb angle values obtained on X-ray images of patients who were diagnosed with scoliosis, kyphosis and osteoporosis, as well as to propose procedures to evaluate the measurement uncertainty of this measurand taking into account each measuring system used. For this, the Cobb angle was measured by three Operators in analog, digital and computerized images in the diagnosis of scoliosis and kyphosis. Two measurement systems were used to carry out the measurements, the analog transponder (analogue images) and the Kinovea software (digital and computerized images). For the diagnosis of osteoporosis, measurements were made only on digital images using Prodigy Lunar software - BMD and Kinovea. The analysis of the results was carried out by applying analysis of variance (ANOVA) using Statistica R. The measurement uncertainty was estimated following the recommendations of the GUM method proposed in JCGM 101. The results indicated that Operator 1 "Experienced" presented the best repeatability of the results and consequently the lower uncertainty. The images with greater curvature in the vertebral column presented worse repeatability of the average values of Cobb angle and consequently higher values of expanded uncertainty, which demonstrates the difficulty to identify the vertebrae limits by the Operators when the angles are larger. The expanded uncertainty values (95%) associated with the Cobb angle for diagnosis of osteoporosis may be of the same order as the value of the measurand in some cases.Dissertação (Mestrado)O presente trabalho tem como objetivo avaliar o efeito do fator Operador nos valores de ângulo de Cobb obtidos em imagens de raio-X de pacientes que foram diagnosticados com escoliose, cifose e osteoporose, bem como propor procedimentos para avaliação da incerteza de medição deste mensurando levando em conta cada sistema de medição utilizado. Para tanto o ângulo de Cobb foi medido por três Operadores em imagens analógicas, digitais e computadorizadas no diagnóstico de escoliose e cifose. Dois sistemas de medição foram utilizados para efetuar as medições, o transferidor analógico (imagens analógicas) e o software Kinovea (imagens digitais e computadorizadas). Para o diagnóstico de osteoporose foi efetuada a medição apenas em imagens digitais utilizando os softwares Prodigy Lunar – BMD e Kinovea. A análise dos resultados foi efetuada aplicando análise de variância (ANOVA) por meio do software Statistica R. A incerteza de medição foi estimada seguindo as recomendações do método GUM proposto no JCGM 101. Os resultados indicaram que o Operador 1 “Experiente” apresentou a melhor repetibilidade dos resultados e consequentemente a menor incerteza expandida. As imagens com maior curvatura na coluna vertebral apresentaram pior repetibilidade dos valores médios de ângulo de Cobb e consequentemente valores maiores de incerteza expandida, o que demonstra a dificuldade de identificar as vértebras limites por parte dos Operadores quando os ângulos são maiores. Os valores de incerteza expandida (95%) associados ao ângulo de Cobb para diagnóstico de osteoporose podem ser da mesma ordem do valor do mensurando em alguns casos.Universidade Federal de UberlândiaBrasilPrograma de Pós-graduação em Engenharia MecânicaMilagre, Selma Terezinhahttp://lattes.cnpq.br/4980687835840176Arencibia, Rosenda Valdéshttp://lattes.cnpq.br/5680475427208141Reis, Ruham Pablohttp://lattes.cnpq.br/6871774879330255Moraes, Raimeshttp://lattes.cnpq.br/6384980259739054Palis, Angélica de Andrade2018-02-15T12:02:14Z2018-02-15T12:02:14Z2017-04-28info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfPALIS, A. A. Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporose. 2017. 113 f. Dissertação de Mestrado, Universidade Federal de Uberlândia, Uberlândia.https://repositorio.ufu.br/handle/123456789/20666http://dx.doi.org/10.14393/ufu.di.2018.41porinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFUinstname:Universidade Federal de Uberlândia (UFU)instacron:UFU2018-02-15T12:02:15Zoai:repositorio.ufu.br:123456789/20666Repositório InstitucionalONGhttp://repositorio.ufu.br/oai/requestdiinf@dirbi.ufu.bropendoar:2018-02-15T12:02:15Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)false |
dc.title.none.fl_str_mv |
Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporose Evauation of factors affecting the analysis of X-ray images for diagnosis of kyphosis, escoliosis and osteoporosis |
title |
Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporose |
spellingShingle |
Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporose Palis, Angélica de Andrade Escoliose Cifose Osteoporose Raio-X Anova Scoliosis Kyphosis Osteoporosis X-ray images Anova CNPQ::ENGENHARIAS |
title_short |
Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporose |
title_full |
Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporose |
title_fullStr |
Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporose |
title_full_unstemmed |
Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporose |
title_sort |
Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporose |
author |
Palis, Angélica de Andrade |
author_facet |
Palis, Angélica de Andrade |
author_role |
author |
dc.contributor.none.fl_str_mv |
Milagre, Selma Terezinha http://lattes.cnpq.br/4980687835840176 Arencibia, Rosenda Valdés http://lattes.cnpq.br/5680475427208141 Reis, Ruham Pablo http://lattes.cnpq.br/6871774879330255 Moraes, Raimes http://lattes.cnpq.br/6384980259739054 |
dc.contributor.author.fl_str_mv |
Palis, Angélica de Andrade |
dc.subject.por.fl_str_mv |
Escoliose Cifose Osteoporose Raio-X Anova Scoliosis Kyphosis Osteoporosis X-ray images Anova CNPQ::ENGENHARIAS |
topic |
Escoliose Cifose Osteoporose Raio-X Anova Scoliosis Kyphosis Osteoporosis X-ray images Anova CNPQ::ENGENHARIAS |
description |
The present study aims to evaluate the effect of the factor Operator on Cobb angle values obtained on X-ray images of patients who were diagnosed with scoliosis, kyphosis and osteoporosis, as well as to propose procedures to evaluate the measurement uncertainty of this measurand taking into account each measuring system used. For this, the Cobb angle was measured by three Operators in analog, digital and computerized images in the diagnosis of scoliosis and kyphosis. Two measurement systems were used to carry out the measurements, the analog transponder (analogue images) and the Kinovea software (digital and computerized images). For the diagnosis of osteoporosis, measurements were made only on digital images using Prodigy Lunar software - BMD and Kinovea. The analysis of the results was carried out by applying analysis of variance (ANOVA) using Statistica R. The measurement uncertainty was estimated following the recommendations of the GUM method proposed in JCGM 101. The results indicated that Operator 1 "Experienced" presented the best repeatability of the results and consequently the lower uncertainty. The images with greater curvature in the vertebral column presented worse repeatability of the average values of Cobb angle and consequently higher values of expanded uncertainty, which demonstrates the difficulty to identify the vertebrae limits by the Operators when the angles are larger. The expanded uncertainty values (95%) associated with the Cobb angle for diagnosis of osteoporosis may be of the same order as the value of the measurand in some cases. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-04-28 2018-02-15T12:02:14Z 2018-02-15T12:02:14Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
PALIS, A. A. Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporose. 2017. 113 f. Dissertação de Mestrado, Universidade Federal de Uberlândia, Uberlândia. https://repositorio.ufu.br/handle/123456789/20666 http://dx.doi.org/10.14393/ufu.di.2018.41 |
identifier_str_mv |
PALIS, A. A. Avaliação dos fatores que afetam a análise de imagens de raio-X para diagnóstico de cifose, escoliose e osteoporose. 2017. 113 f. Dissertação de Mestrado, Universidade Federal de Uberlândia, Uberlândia. |
url |
https://repositorio.ufu.br/handle/123456789/20666 http://dx.doi.org/10.14393/ufu.di.2018.41 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Uberlândia Brasil Programa de Pós-graduação em Engenharia Mecânica |
publisher.none.fl_str_mv |
Universidade Federal de Uberlândia Brasil Programa de Pós-graduação em Engenharia Mecânica |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFU instname:Universidade Federal de Uberlândia (UFU) instacron:UFU |
instname_str |
Universidade Federal de Uberlândia (UFU) |
instacron_str |
UFU |
institution |
UFU |
reponame_str |
Repositório Institucional da UFU |
collection |
Repositório Institucional da UFU |
repository.name.fl_str_mv |
Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU) |
repository.mail.fl_str_mv |
diinf@dirbi.ufu.br |
_version_ |
1813711573471985664 |